![Renova turborex TSP 180 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/renova/turborex-tsp-180/turborex-tsp-180_operating-instructions-manual_1442997013.webp)
13
fans
•
After making the various connections, turn on the fans.
The voltage of the standards fans is 24 VDC.
At the request of customers, we sometimes mount voltage of 110
VAC and 220 VAC which we do not recommended because they are
potentially dangerous for the people working on the brake.
It is preferable to use a transformer that we can supply as an option.
The fans normally used are divided into
standard and hp (high power)
with enhanced cooling characteristics.
Type
Voltage
Power
Sound level
Renova code
Standard
24 V CC
11 W
57 dB(A)
VT12038024
High performance HP4
24 V CC
30 W
67 dB(A)
VT120380H4
High performance HP6
24 V CC
65 W
73 dB(A)
VT120380H6
Standard 110 V
110 V AC
20 W
51 dB(A)
VT12038110
Standard 220 V
220 V AC
19 W
47 dB(A)
VT12038220
Fans dimensions: 120mm x 120mm x 38mm.
•
Check that the fans are working correctly, one in suction and the opposite in pressure
Once all the mechanical, pneumatic and electrical steps have been carried out, the brake is ready for use.