Example:
TEST GPSZONE 1 #1513
The following SMS message is returned as confirmation:
GKA200 v1.xx
Product name, Firmware version
GPS zone: 1
Number of the defined safety zone
Latitude1:
Latitude in left upper corner
49.549680N
Longitude1:
Longitude in left upper corner
11.924780E
Latitude2:
Latitude in right lower corner
49.537480N
Longitude2:
Longitude in right lower corner
11.957910E
Free GPS zone:
remaining free GPS safety zones
8,9,10
Programming an alarm pause between two alarm triggers
In the event of an alarm, the alarm system sends an alarm notification. More notifications of the
same type will only be sent, if the corresponding alarm event for a defined time frame (alarm
pause, factory setting: 5 minutes) is exceeded.
You can change the alarm pause settings.
To do this, use the following SMS command
SET IDLEALARM <Time> #1513
The parameter “Time”an be set between 1 and 240 minutes.
Example:
SET IDLEALARM 15 #1513
The time between alarm notifications is set to 15 minutes.
During the alarm pause no new alerts about a change in the alarm situation will be
sent. However, the user can check the parameters of the alarm pause.
31