Interface switch descriptions
HCU2 operation
When the system is used in conjunction with an HCU2 hand control unit, the probe damp and probe reset buttons on the HCU2 are active.
The probe reset button will pulse the PPOFF PICS line when pressed, but only while the system is in manual mode. The probe damp button
will toggle the PDAMP PICS line when pressed, but only while the system is in manual mode. Both the probe reset and probe damp buttons
on the HCU2 can be made inactive by use of a switch on the rear panel of the PHC10-3.
Switch
Description
Position
8
Operation of HCU2 probe
damping and probe reset
UP
Enabled
8
Operation of HCU2 probe
damping and probe reset
DOWN
Disabled
Probe reseat time
The extended probe reseat timer on the PHC10-3 PLUS unit is designed to be used where the touch probe fails to fully seat within the
standard reseat period following a head index move (e.g, when using long extension bars).
Switch
Description
Position
10
Time permitted for probe to
reseat following a head index
UP
Extended
10
Time permitted for probe to
reseat following a head index
DOWN
Standard
Interface connection
Switch
Description
Position
11
Probe connection
UP
PICS or 7-pin DIN operation: the
PHC10-3 PLUS internal inhibit
relay disables the interface
during a head index
11
Probe connection
DOWN
5-pin DIN operation only: the
PHC10-3 internal inhibit relay
disables the probe during a head
index
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 12 2021
30