![Renishaw PHC10-3 PLUS Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/renishaw/phc10-3-plus/phc10-3-plus_installation-manual_1441294015.webp)
PHC10-3 PLUS configuration switches
PHC10-3 PLUS switch settings
PHC10-3 PLUS switch
Function
Up
Down
Communications
1#
Baud rate
2#
Baud rate
3#
Baud rate
4*#
Stop bit
2 stop bits
1 stop bit
5*#
CTS protocol
CTS on
CTS off
6*#
LF protocol
LF on
LF off
9
Command set
Extended
Basic
Interface
7
PICS configuration
PPOFF - active during head index
PPOFF - inactive during head
index
8
HCU2 PROBE/DAMP/RESET
Enabled
Disabled
10
Probe reseat time
Extended
Standard
11
Interface connection
PICS / 7 pin DIN
5-pin DIN
12
Output configuration
PICS
DIN
13
Machine cable isolation
Machine cable
Multiwire
* Operational only when basic command set selected (switch 9 down).
# Not required for USB operation default position = down.
NOTE:
Press the reset button after making switch changes.
Conversion from PHC10-2 to PHC10-3 PLUS
PHC10-3 PLUS is designed to be a plug in functional replacement for PHC10-2. There are some differences which the user needs to be aware
of, the connectors have been rearranged on the rear panel but are of the same type and are labelled in the same way. A USB connector has
been added for those requiring USB communications. Unused switches have been removed and the remaining switches are now grouped in
one row. See the next table for changes.
PHC10-3 PLUS installation guide
www.renishaw.com