PHC10-3 PLUS front panel LEDS
PHC10-3 PLUS LED description
Name
Colour
Function
POWER
Green
Power on when lit
STOP
Red
PHC10-3 PLUS asserting PICS STOP when lit
PI 200-3 asserting PICS STOP when flashing
HEAD READY
Green
Head ready for use when lit
HEAD ACTIVE
Yellow
Head indexing when lit
DATUM ERROR
Red
Head datum error when lit
OBSTRUCT ERROR
Red
Head obstruct error when lit, non PLUS
interface fitted
OVERLOAD ERROR
Red
Head overload error when lit
TP7
Green
TP7 detected when lit
TP200
Green
TP200 detected when lit
STD
Green
TP2 / TP20 / TP6 detected when lit
SEATED
Green
Probe seated when lit
DAMPED
Yellow
Probe damped when lit
NOTE:
The probe reset button on the front of PHC10-3 PLUS only functions if a probe interface card is installed within the unit.
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 12 2021
19