21
System installation
MRC 19
ARC 18
N/C 2
N/C 3
N/C 4
N/C 5
N/C 12
N/C 14
N/C 15
N/C 16
N/C 17
N/C 24
N/C 20
N/C 21
ARO 6
MRO 7
V
IF
1
V
IF
8
V
IF
9
0 V
IF
13
0 V
IF
25
Motor supply V
M
10
Motor supply V
M
22
Motor supply 0 V
M
11
Motor supply 0 V
M
23
Screen Shell
0 V
1
Inhibit return
2
Inhibit 3
External LED 0 V
4
External LED 10 V 5
N/O* 6
Common 7
N/C** 8
12 - 30 V Out
9
Screen 10
Supply 0 V
11
Supply 12 - 30 V 12
MRC
ARC
ARO
MRO
18 V to 30 V
0 V
24 V (+20% to -10%)
0 V
Probe input
Screen
0 Vdc
12 - 30 Vdc
Machine controller
SSR
Power input
Interface 24 V
supply
(18 V to 30 V)
Motor 24 V
supply
+20% to -10%
Controller protective
earth (also referred to
as PE starpoint or earthplate)
Inhibiting the probe,
refer to page 28 for
connection information
Status
*Normally open
(N/O)
**Normally closed
(N/C)
Probe triggered
Closed
Open
Probe seated
Open
Closed
Controller connector
(12 way)
Controller connector
(25 way)