Fault finding
Symptom
Symptom
Cause
Action
Poor system
repeatability (continued)
Excess machine vibration. Eliminate vibration.
Minor collision.
Move arm to stow position
and back to active position
to reset arm to kinematic
seating.
Symptom
Cause
Action
No probe output
Damaged or dirty probe
contacts.
Check condition of probe
contacts. If contacts
are dirty, clean using
compressed air and a
clean lint-free cloth.
Probe not connected.
Check wiring to machine.
Check probe is fully
screwed into holder.
Probe has failed.
Remove probe and check
probe for continuity across
probe contacts (resistance
should be less than 1 K
W
).
NOTE:
The action
mentioned is only
applicable to the LP2
probe.