4.5 JOIN MODULES TOGETHER

4.5.1 Bolt Together at Lifting Lugs

Align modules and push together using forklift or other means, compressing the gasket tape.  The 

lower lifting lugs are equipped with 2” diameter holes that 1.5” dia. (2” OD) steel pipe could be used 

to assist in alignment. 

See Lifting Lug illustration on page 8 of this manual.

 Joining lift lugs also have a 

spacing bolt at the tip of one lug that will fit into the empty lug hole of the other module for alignment 

and lug tip spacing.

After positioning the modules together, compressing the gasket tape, insert eight 3/8” - 16 x 1-1/4 

plated hex head bolts through the holes on the lifting lugs and base rail (LE-IN) or base supports 

(LE-RT) of the two adjacent modules. Use 3/8” washers between the bolt head and the unit and 

between the nut and the unit. Fasten the nuts to the bolts secure the bases of the two modules  

together tightly. 

ALIGNMENT / 

SPACER

BOLT

LE INDOOR UNITS:

INSTALL 2 BOLTS IN THE MATING LIFT-

ING LUGS AND THEN 2 MORE BOLTS 

IN THE MATING BASE RAILS. TYPICAL 

EACH SIDE OF LE UNIT.

2 BOLTS THROUGH LIFTING 

LUGS (EACH SIDE OF UNIT)

HAND HOLES (TYP, EACH 

SIDE OF UNIT)

2 BOLTS THROUGH LIFTING 

LUGS (EACH SIDE OF UNIT)

2 BOLTS THROUGH BASE RAILS (EACH SIDE 

OF UNIT).  ACCESS BOLT AND NUT THROUGH 

THE HAND HOLES IN EACH MODULE SIDE BASE 

RAIL TO BE JOINED.

2 BOLTS THROUGH BASE SUP-

PORTS (EACH SIDE OF UNIT).

ACCESS BOLT AND NUT 

THROUGH HAND HOLES IN 

EACH MODULE SIDE BASE RAIL 

TO BE JOINED.

LE ROOFTOP UNITS:

INSTALL 2 BOLTS IN THE 

MATING LIFTING LUGS AND 

THEN 2 MORE BOLTS IN BASE 

SUPPORT.

LE Indoor Unit Base Bolt Locations

LE Rooftop Unit Base Bolt Locations

Alignment / Spacer Bolt Location

Module Positioning Technique

Содержание LE-8X*INH Series

Страница 1: ...SHIPPING RIGGING HOISTING AND ASSEMBLY MANUAL ENERGY RECOVERY VENTILATORS RENEWAIRE COM LE6X LE8X LE10X...

Страница 2: ...ll lifting lugs provided must be used Never lift the unit or modules from the top of the unit This unit is intended for general ventilating only Do not use to exhaust hazardous or explosive materials...

Страница 3: ...ATION AND MAINTENANCE MANUAL RENEWAIRE COM OWNER INFORMATION IMPORTANT USER INFORMATION SAVE THIS MANUAL In the unlikely event that factory assistance is ever required information located on the unit...

Страница 4: ...OODS 16 4 8 INSTALL MERV 8 FILTERS 17 5 0 ROOFTOP CURB DIMENSIONS 18 5 1 LE6XRT CURBS 18 5 2 LE8XRT CURBS 18 5 3 LE10XRT CURBS 19 6 0 ROOFTOP UNIT DIMENSIONS 20 6 1 LE6XRTH F DIMENSION DRAWING 20 6 2...

Страница 5: ...ations 11 LE Rooftop Unit Base Bolt Locations 11 Alignment Spacer Bolt Location 11 Roof Beam Assembly Graphic 2 12 Roof Beam Assembly Graphic 1 12 Roof Beam Assembly Bolt Locations 12 Roof Cap Caulkin...

Страница 6: ...Shipping Location typ Hoods are assembled at the factory and then secured for shipment inside the ERV LE models can be delivered in two modules for on site assembly or as a complete unit additional c...

Страница 7: ...clearance between the cables and the cabinet or any of the equipment attached to the unit or modules Provide additional blocking or covering as required Secure hooks and cables at all lifting points...

Страница 8: ...AND MAINTENANCE MANUAL 1 800 627 4499 8 RIGGING www renewaire com 800 627 4499 support renewaire com www renewaire com 800 627 4499 support renewaire com www renewaire com 800 627 4499 support renewa...

Страница 9: ...ed unassembled for applications where modules must be manipulated separately If the unit was ordered unassembled then you will need to assemble the modules in the field Each module is labeled with a c...

Страница 10: ...disposed of along with the screws that held them in place www renewaire com 800 627 4499 support renewaire com Apply 1 2 X 1 gasket tape provided as shown below Gasket tape creates an airtight seal be...

Страница 11: ...N or base supports LE RT of the two adjacent modules Use 3 8 washers between the bolt head and the unit and between the nut and the unit Fasten the nuts to the bolts secure the bases of the two module...

Страница 12: ...nsert 1 4 20 x 1 00 Grade 5 zinc plated hex head bolts through the holes in the roof beam Secure the nuts to secure the roof section www renewaire com 800 627 4499 support renewaire com AFTER THE LIFT...

Страница 13: ...ewaire com A galvanized cap roof flange is provided to seal the roof seam and to maintain a water and airtight seal The cap roof flange is provided with pre drilled holes 12 X 75 hex head tek screw w...

Страница 14: ...l not to over tighten the screw www renewaire com 800 627 4499 support renewaire com Two 2 galvanized roof cap ends are provided to seal the top end of each module and maintain a water and airtight se...

Страница 15: ...n the electrical connection cover on the E Box side of the front module by removing screws in the access panel The access panel is located in the upper left corner of the front module to the left of t...

Страница 16: ...4499 support renewaire com www renewaire com 800 627 4499 support renewaire com www renewaire com 800 627 4499 support renewaire com Slide the top flange of the OA air hood beneath the roof panel over...

Страница 17: ...that when filters are installed the filter spacers may tend to fall off the end of the filter receiving channels If this happens simply install the spacers between the first two filters in from the d...

Страница 18: ...EA FA RTV 16 1 8 X 19 1 2 Opening 115 1 4 O D 64 1 4 O D 3 60 1 2 I D 17 1 4 33 20 25 9 1 2 A A TOP VIEW CURB LE6X FA RA LEFT VIEW Model LE6X RTV RTR Drawing Type Unit Dimension Version MAY18 LE6XRT...

Страница 19: ...Lugs 4 111 1 4 Overall 69 1 8 Case 2 Typ 2 Duct Flange Typ C L 2 1 4 Wiring Pressure Ports 4 Typ 4 1 2 37 7 8 44 5 8 69 5 8 Case 71 1 8 Overall 29 5 8 53 1 2 47 1 4 84 5 8 9 C L 5 1 4 2 7 8 Knockouts...

Страница 20: ...ard AIRFLOW CONFIGURATION Available as shown UNIT MOUNTING APPLICATION Must be mounted as shown Airstreams can not be switched EA A R A F OA HERT except 6x 8x LERT RTV OA A R EA FA HERT except 6x 8x L...

Страница 21: ...CONFIGURATION Available as shown UNIT MOUNTING APPLICATION Must be mounted as shown Airstreams can not be switched EA A R A F OA HERT except 6x 8x LERT RTV OA A R EA FA HERT except 6x 8x LERT RTR RENE...

Страница 22: ...GURATION Available as shown UNIT MOUNTING APPLICATION Must be mounted as shown Airstreams can not be switched EA A R A F OA HERT except 6x 8x LERT RTV OA A R EA FA HERT except 6x 8x LERT RTR RENEWAIRE...

Страница 23: ...ator Standard AIRFLOW CONFIGURATION Available as shown in dimension drawing UNIT MOUNTING APPLICATION Must be mounted as shown RA EA airstream can be switched with OA FA airstream unless certain optio...

Страница 24: ...GURATION Available as shown in dimension drawing UNIT MOUNTING APPLICATION Must be mounted as shown RA EA airstream can be switched with OA FA airstream unless certain options are selected FOR THE MOS...

Страница 25: ...ATION Available as shown in dimension drawing UNIT MOUNTING APPLICATION Must be mounted as shown RA EA airstream can be switched with OA FA airstream unless certain options are selected FOR THE MOST C...

Страница 26: ...CORNER WEIGHTS AT LIFTING LUGS BASIC UNIT WEIGHTS lbs Motors UNIT LF LR RR RF 3 HP 2086 579 580 464 463 2100 583 585 466 465 2218 625 630 483 480 5 HP 7 5 HP Options UNIT LF LR RR RF ADDITIONAL WEIGHT...

Страница 27: ...X INH Front Module Corner Weights Sheet 3 of 4 73 5 Lifting Lug LR RR LF RF 119 5 Lifting Lug CORNER WEIGHTS AT LIFTING LUGS BASIC UNIT WEIGHTS lbs Motors UNIT LF LR RR RF 3 HP 1984 569 433 424 558 19...

Страница 28: ...ng LE 8XRT_CORNER LE 8X RT Fron Corner Weigh 73 5 Lifting Lug LR RR LF RF 159 5 Lifting Lug BASIC UNIT WEIGHTS lbs Motors UNIT LF LR RR RF 3 HP 2625 753 680 568 624 2645 745 737 578 585 2763 790 780 5...

Страница 29: ...ing LE 8X INH Front Module Corner Weights Sheet 3 of 4 73 5 Lifting Lug LR RR LF RF 159 5 Lifting Lug BASIC UNIT WEIGHTS lbs Motors UNIT LF LR RR RF 3 HP 2495 727 524 521 723 2509 733 524 522 730 2627...

Страница 30: ...ro Corner Weigh LE10X RT_CORNE 73 5 Lifting Lug LR RR LF RF 194 5 Lifting Lug BASIC UNIT WEIGHTS lbs Motors UNIT LF LR RR RF 3 HP 3031 842 841 674 674 3045 847 846 676 676 3163 892 890 690 691 5 HP 7...

Страница 31: ...nt Module Corner Weights Sheet 3 of 4 73 5 Lifting Lug LR RR LF RF 194 5 Lifting Lug BASIC UNIT WEIGHTS lbs Motors UNIT LF LR RR RF 3 HP 2859 819 665 616 759 2873 825 666 617 765 2990 874 676 628 812...

Страница 32: ...ulting in significant energy savings Our ERVs are competitively priced simple to install easy to use and maintain and have a quick payback They also enjoy the industry s best warranty with the lowest...

Отзывы: