![Renewable Energy Global 2009122A Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/renewable-energy-global/2009122a/2009122a_installation-manua_1440958016.webp)
15
INSTALLATION MANUAL FOR MODEL: GSE IP-195
Leg pad
2 x 4” Preserved Wood
2 x 6” Preserved Wood
SECTION A - A
A
5’-8”
2’-8”
2’-8”
Dimensions
4’-6”
5’-3”
17”
3’-9”
5-3””
RooF MoUnTInG deTAIls
10. Roof Mounting details (Flat Roof)
The installation manual must give instructions to meet local code requirements for penetrating structural members
and fire-rated assemblies. The intent of these paragraphs can be met with statements in the installation portion of the
manual instructing the installer to run the piping in such a way that the performance of any structural member or fire
rated assembly is not reduced. It will then be up to the local code to dictate exactly how this is done. (GUIDE: 6.5.19)
11. Grounding
Aluminium Leg
Ground Pad
Bolt
Ground Wire
Nut
Cold Water Pipe
Ground Wire
Star Washers
Typical Mounting Details
Grounding Details (Outside)
Grounding Details (Inside)
1’-8”
1’-5”
1’-8”