VILLAGIO OWNERS MANUAL
Renegade RV
574.848.1126
Page 96
Rev.712a
This owner’s manual is subject to change
Updates will be posted on our web site
AT WWW. Renegaderv.com
The house battery may be low on charge. Plug in the external power cord (shoreline), star the
engine, or start up the generator (if equipped). This may assist slide out room operation.
The chassis battery may be low on charge. Press and Hold the Battery Boost switch (located on
the dash) while pressing the interior slide out control switch. This momentarily connects the
house batteries to assist in slide out room operation.
The circuit breaker may be tripped. The circuit breaker, labeled "Slide out Power" is located on a
panel on an interior wall of the passenger side storage compartment just behind or ahead of the
entrance door.
• Status • Motor • Mode
LED's Direction Button
• Motor 1 Connection
• Motor 2 Connection
Slide out Room Controller
(Located in a driver or passenger side
compartment, depending on model)
- Remove panel to access
Error Codes
When an error occurs during slide out room operation, the slide out control panel (located in
passenger side compartment) will use LED display lights to indicate where the problem exists.
For specific motor faults, the green LED light will blink 1 time for Motor 1 and 2 times for Motor
2. The red LED light will blink from 2 to 9 times, depending on the error code. The error codes
are as follows:
(2) - BATTERY DROP OUT. Battery
capacity low enough to drop below 6 volts while running.
(3) -LOW BATTERY. Voltage below 8 volts at start of cycle.
(4) - HIGH BATTERY. Voltage greater than 18 volts.
(5) - EXCESSIVE MOTOR CURRENT.
High amperage (also indicated by one side of Slide out room continually stalling).
(6) - MOTOR SHORT CIRCUIT. Motor or wiring to motor has shorted out.
(8) - HALL SIGNAL NOT PRESENT.
Encoder is not providing a signal. This is
usually a wiring problem.
(9) - HALL POWER SHORT TO
GROUND. Power to encoder has been
shorted to ground. This is usually a wiring problem.
NOTE:
When an error code is present, the Slide out control panel needs to be reset. Operating
the Extend/Retract switch will reset the slide out control panel. Operate the Extend/Retract
switch again for normal operation
.