Heat exchanger
The heat exchanger (type 2-pass) is mounted on the chassis. To ensure proper heat transfer of the combustion
gases, the copper fin tubes are arranged side by side and expanded laterally into a mounting plate.
The baffles on the copper fin tubes optimize the efficiency of the heat exchanger.
The supply and return pipes, together with the water manifolds, form the heat exchanger.
Burner
The burner is mounted under the combustion chamber in the chassis.
The burner bars, mounted in the burner trolley are manufactured from stainless steel.
Each burner bar is supplied by its own injector nozzle mounted on the gas manifold.
Fig. 6
Burner
Fig. 5
Heat exchanger