Basic settings for the hydraulic diagram
Menu item
Parameter
Factory setting
Country
Deutschland - Slovensko
Germany
Load setting
Accept the parameters
Saving process
Language
Deutsch - Polski
Deutsch
Time zone
Var. time zones possible
1(CET)
Date
Year/Month/Day
Basic settings
Time
Hours/Minutes
Basic settings
Restore counter readings?
YES/NO
NO
Load user settings?
YES/NO
NO
Activate heat pump
Activated / Deactivated
Activated
Passive cooling
Activated / Deactivated
Deactivated
Operating mode
Monoenergetic/bivalent alternative
Monoenergetic
Brine outlet setpoint
-15 °C - +20 °C
+8 °C
Anti-freeze protection temp.
-20 °C - +10 °C
+4 °C
Anti-freeze protection alarm temp.
-25 °C - +5 °C
+2 °C
Domestic hot-water heating
Activated / Deactivated
Activated
Storage tank set temperature
"40°C - 65°C"
45 °C
Hot water circulation
Activated / Deactivated
Activated
Circulation type
Impulse/Temperature
Impulse
Circulation set temp.
"25 °C - 65°C"
Deactivated
Circulation running time
1 min - 15 mins
5 min
Disable switch-on
1 min - 15 mins
5 min
Unmixed heating cycle
Activated / Deactivated
Activated
Operating mode
Heating/cooling Heating and cooling
Heating
Heating cycle mode
Heating curve/Fixed value
Heating curve
Heating curve adjustment
Base point/standard inlet temperature/
standard outside temperature
According to design
Fixed value
"10 °C - 50 °C"
Deactivated
Cooling cycle mode
Cooling curve/Fixed value
Deactivated
Fixed value
"8 °C - 35 °C"
Deactivated
Cooling curve adjustment
Base point/standard inlet temperature/
standard outside temperature
Deactivated
1st mixed cycle
Activated / Deactivated
Deactivated
Operating mode
Heating/cooling Heating and cooling
Deactivated
Heating cycle mode
Heating curve/Fixed value
Deactivated
Heating curve adjustment
Base point/standard inlet temperature/
standard outside temperature
Deactivated
REMKO Smart-Control Touch
90