Cleaning the fuel tank 

It is necessary to clean the fuel tank: 

After each heating period or, depending on the deploy-
ment conditions, even earlier. 

Before and after extended idle periods. 

If the main filter frequently becomes dirty. 

If condensation water accumulates in the fuel. 

Rinse the container several times if necessary with 
clean fuel thoroughly. 

Do not use water!. 

Please use no cleaning agents which contain 
solvents.  

These can destroy the inner layer of the tank. 

Avoid the use of high-pressure cleaners. 

Fit the discharging screw 

D

 (SW 22). 

The gasket ring 

E

 should be replaced after each 

disassembly. 

Fill tank with clean fuel. 

Start unit and let it run for approx. 3 minutes.

 

Please proceed in the following way when cleaning the 
fuel tank. 

Unscrew the discharging screw 

D

 (SW 22) and dis-

charge the fuel into a suitable vessel. 

Burner adjustment

 

 

Disassembly of burner head and nozzle 

1.   Loosen cap nut of fuel piping at burner head. 

2.   Remove photo cell and ignition cable, and remove 

the burner head by turning from the rear wall of the 
burner chamber. 

3.   When maintenance has been carried out re-assemble 

all parts carefully in reverse order. 

4.   Pre-set air flow plate, air slide plate and the ignition 

electrode distance according to the approximate indi-
cations. 

G

 

Use only appropriate tools to disassemble the 
nozzle (SW 16) and counteract at the blast con-
nection (SW 19). 

Adjustments of the burner head 

Fine adjustment of air slide plate by means of CO

2

 

indicator and soot pump. 

CO

- value:    approx. 10 - 12 % 

Soot figure:   0 - 1 (by Bacharach)

 

G

 

Make sure to avoid a flame leakage outside the 
combustion chamber. 

Technical Data 

Nominal heat output 

kW 

18 

Air output 

m³/h 

600 

Fuel 

fuel oil EL or diesel oil 

Fuel consumption, max. 

kg/h 

1,52 

Nozzle (60°W) 

USG 

0,4 

Pump pressure approx. 

bar 

11 

Tank capacity 

Ltr. 

16 

Electrical connection 1~ 

V / Hz  

230 / 50  

Rated current max. 

1,2 

Power consumption max. 

1)

 

kW 

0,29 

Fuse protection (required) 

10 

Sound pressure level L

pA 

1m

 

2)

  dB(A) 

70 

Length  

mm 

810 

Width 

mm 

380 

Height 

mm 

480 

Weight 

kg 

26 

 

 

 

1) unit inclusive tank heating 

2) noise measuring  (when heating) DIN 45635 - 01 - KL 3

 

Содержание DZ 18 HD

Страница 1: ...REMKO powerful like a bear REMKO DZ 18 HD Automatic oil heater Edition GB M04 Operation Technology Spare Parts...

Страница 2: ......

Страница 3: ...t list 11 Wiring diagram 12 Service and guarantee 12 Troubleshooting 13 Maintenance log 14 Automatic oil heater REMKO DZ 18 HD Make sure to read these instructions carefully before starting using the...

Страница 4: ...upply air fan contin ues running for some time to cool down the combustion chamber and then it stops automatically Depending on the required heat rate the function de scribed above is repeated automat...

Страница 5: ...ated in rooms and areas where the danger of fire or explosion ex ists 3 Room drying 3 1 In deviation from point 2 3 in order to dry rooms with an air supply sufficient for the combustion heating units...

Страница 6: ...a special supply point with fault current safety switch Starting Prior to starting the unit is to be checked to make sure that there are no visible defects on the control and safety devices that the...

Страница 7: ...ng set the pressure Fuel Pump The standard type of the pump runs in a system of 1 pipe The required fuel is sucked in through the suction line S For the first starting and after having emptied the fue...

Страница 8: ...ervals Maintenance and Service The unit is to be maintained regularly whereby some fundamental rules are to be observed to ensure a long service life and trouble free operation After each heating peri...

Страница 9: ...hoto cell and ignition cable and remove the burner head by turning from the rear wall of the burner chamber 3 When maintenance has been carried out re assemble all parts carefully in reverse order 4 P...

Страница 10: ...31 24 26 27 25 28 33 34 36 37 37a 42 41 47 48 50 49 46 13 44 15 19 43 6 3 2 45 9 10 18 4 8 14 35 5 39 38 40 32 51 52 54 53 22 We reserve the right to make modifications in dimensions and construction...

Страница 11: ...with plug 1101320 25 traction relief 1108325 26 bridge circuit plug 1101019 27 thermostat socket 1101018 28 fan housing 1101803 29 filler cap 1101716 30 fuel filter filler neck 1101717 31 control IC...

Страница 12: ...r or his customer has filled in completely the guarantee certificate which is enclosed with every REMKO heater and has returned it to REMKO GmbH Co KG in due time after the unit s sale and commissioni...

Страница 13: ...ng dimension type size Replace nozzle take care of correct type and size 11 Wrong setting of ignition electrodes or damaged insulation Adjust correctly resp replace it 12 Air flow plate of the burner...

Страница 14: ...ge Check fastening screws Electric safety inspections Test run Model Model No Setting and maintenance work is to be carried out only by authorised specialists Remarks 1 Date 2 Date 3 Date 4 Date 5 Dat...

Страница 15: ......

Страница 16: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260...

Отзывы: