17
white
white
brown
orange
black
blue
Electrical wiring diagram
Multiflex oil pre-heating
Optional: For CLK 30/50 and 70.
Series:
With CLK 120/150 with oil burner
fitted ex works.
Legend:
C
= Start-up capacitor
H1
= Operating lamp (green)
H2
= External burner fault lamp (red)
KL
= Terminal block
M
= Fan motor
RT
= Thermostat socket
S1
= Operating switch
S2
= Reset button (burner)
STB
= Safety temperature limiter
TR
= Temperature controller
TW
= Temperature monitoring device
WS
= Burner plug, 7-pin
(only fitted with factory burner delivery)
ÖV
= Multiflex oil pre-heating
We reserve the right to modify the dimensions and design as part of the ongoing technical development process.