REMKO ATK 50-S Скачать руководство пользователя страница 9

9

2

1

Shutdown

1.   Move the operating 

switch to the "0" 
(Off) position.

The supply air fan runs to cool 
the combustion chamber and 
switches off independently.  
The fan can switch on and run 
several times before the final 
shutdown!

2.   With longer periods 

of inactivity, 
disconnect the units 
from the mains 
power supply. 

Care and maintenance

Heating with room thermostat

The units operate fully 
automatically and according 
to the room temperature.

1.   Pull out the strapping plug [2].

2.   Connect the room thermostat 

plug [3] to the thermostat 
socket [1] on the unit.

3.   Place the room thermostat at a 

suitable location in the room. 
The thermostat sensor must 
not be located directly in the 
warm air flow and must not 
be placed directly on the cold 
floor.

4.   Set the desired room 

temperature on the room 
thermostat.

5.  Move the operating switch to 

the "I" (Heating) position.

The unit starts 
automatically after a brief 
burner pre-ventilation if 
heat is required and then runs fully 
automatically.

3

1

1

2

Regular care and observation 
of some basic requirements will 
ensure trouble-free operation and 
a long service life of the units.  
The units, including combustion 
chamber and burner, must be 
cleared of soot deposits, dust and 
dirt after every heating period 
or according to the operating 
conditions.  
The oil filters must be cleaned and/
or replaced at least once annually 
or more frequently according to 
the contamination of the fuel.

   Keep the units free of dust and 

other debris

   Only clean the units with a dry 

or moistened cloth

   Never subject to direct jets of 

water. 
such as a high-pressure cleaner 
etc.

   Never use abrasive or solvent-

based cleaners

   Use only suitable cleaners, even 

for heavy contamination

ATTENTION

Before undertaking any work 
on the units, the power 
plug must be removed from 
the mains socket. There is 
an acute risk of injury from 
automatic fan switch-on, 
especially when the unit 
enclosure is opened.

ATTENTION

Never interrupt the power 
supply prior to the completion 
of the follow-up cooling phase.  
There is no warranty claim 
for damage to the units from 
overheating.

Heating without room 
thermostat

The units operate 
in permanent operating mode.

1.

   Connect the supplied strapping 

plug [2] to the thermostat 
socket [1] on the unit.

2.

   Move the operating 

switch to the "I" 
(Heating) position.

NOTE

Adjustment and maintenance 
work may only be carried out 
by authorised and qualified 
technicians.

s

s

s

Содержание ATK 50-S

Страница 1: ...Edition GB I02 REMKO ATK 50 S Automatic oil heater with built in oil burner tank and exhaust gas connection Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...or on the unit itself Subject to modifications no liability accepted for errors or misprints Safety notes 4 Environmental protection and recycling 4 Unit description 5 Installation instructions 6 7 E...

Страница 4: ...ed by untrained personnel The following notes must be observed in full The power plug must be pulled out of the mains socket before maintenance and repair work The units may only be operated by person...

Страница 5: ...reset key 2 1 Unscrew the protective cap 1 2 Carefully press in the reset key 2 with a suitable tool 3 Screw the protective cap 1 back on again 4 Reset the automatic burner Operating sequence The sup...

Страница 6: ...ge due to inclement weather units installed outdoors must be adequately protected NOTE Overpressure and underpressure in the installation area should be avoided as this will inevitably lead to combust...

Страница 7: ...g the 1st BImSchV Units that are not expected to be operated for longer than 3 months in the same location are not subject to any approvals or monitoring as per the 1st BImSchV The units can be transp...

Страница 8: ...suitable and clean fuels may be used ATTENTION In the event of defects that endanger the operational safety of the units operation of the units must be discontinued immediately and the supervisor inf...

Страница 9: ...e of the units The units including combustion chamber and burner must be cleared of soot deposits dust and dirt after every heating period or according to the operating conditions The oil filters must...

Страница 10: ...alues 7 Following maintenance work refit all parts carefully in reverse order NOTE When positioning the baffle plate 7 always ensure that the aperture 5 is not obscured by a strut on the plate s s s C...

Страница 11: ...e pump run for extended periods without any fuel Never leave the units for extended periods with a pump that has run dry Exhaust gas analysis To perform the exhaust gas analysis the exhaust gas measur...

Страница 12: ...s Exploded view of the unit B 69 B 54 52 53 32 34 35 97 31 99 39 98 42 41 123 111 116 100 117 15 22 119 101 102 104 103 105 30 18 11 A 80 1 125 126 95 92 121 27 24 28 19 70 23 40 114 90 113 50 112 122...

Страница 13: ...40 STB support bracket 1103981 104 Connection nipple 1 4 1111674 41 Cable gland 1103982 105 Connection nipple 1 8 1111672 42 Counter nut 1103983 111 Fuel filter one way 1102146 50 Combustion chamber...

Страница 14: ...fuel pump and replace if necessary 9 The fuel tank is empty Fill the fuel tank with clean EL heating oil or diesel 10 The fuel filter is contaminated Replace the fuel filter 11 The nozzle is blocked...

Страница 15: ...n max 1 kW 0 85 Electrical protection provided by the customer A 10 Sound pressure level LpA 1m 2 dB A 74 Exhaust connection mm 150 Dimensions Length mm 1535 Width mm 650 Height mm 1005 Weight kg 102...

Страница 16: ...must be advisers to our customers in air conditioning and heating technology Customer service Our units operate precisely and reliably However in the event of a malfunction REMKO customer service is...

Отзывы: