REMKO ATK 50-S Скачать руководство пользователя страница 4

4

REMKO ATK

Safety notes

Always observe the respective local building code and fire prevention 
guidelines as well as the guidelines of the accident prevention and 
insurance associations when using the equipment.

Disposing of packaging

When disposing of packaging 
material, please consider our 
environment.
Our units are carefully packed 
and delivered in stable transport 
packaging and, if applicable, on a 
wooden pallet.
The packaging materials are 
environmentally friendly and can 
be recycled.
By recycling packaging materials, 
you make a valuable contribution 
to the reduction of waste and 
conservation of raw materials.

Therefore, only dispose of 
packaging material at appropriate 
collection points.

Disposal of the old unit

 

The manufacturing process for 
the units is subject to continuous 
quality control.

Only high-grade materials are 
processed, the majority of which 
are recyclable.

You also contribute to 
environmental protection by 
ensuring that your old equipment 
is only disposed of in an 
environmentally-friendly manner.

Therefore, only take the old 
unit to an authorised recycling 
business or to an appropriate 
collection point.

The units have been subjected 
to extensive material, functional 
and quality inspections prior to 
delivery. However, dangers can 
arise from the units if they are used 
improperly or not as intended by 
untrained personnel! 
 
The following notes must be 
observed in full

   The power plug must be pulled 

out of the mains socket before 
maintenance and repair work

   The units may only be operated 

by persons that have been 
instructed in their operation

   The units must be installed and 

operated in such a way that 
personnel are not endangered 
by exhaust and radiant heat 
and that no fires may occur

   The units must then only 

be operated in areas where 
the units can be supplied with 
an adequate amount of air for 
combustion

   Without exhaust routing, 

the units may only be operated 
in well ventilated spaces. 
Personnel must not remain in 
the installation area.  
Appropriate prohibition 
signs must be erected at 
the entrances!

   Set the units down on a 

level and non-combustible 
base

    The units may not be installed 

or operated in potentially 
flammable or explosive 
environments

   The units must not be installed 

or operated in atmospheres 
containing oil, sulphur or salt

   A safety zone of 1.5 m must be 

maintained around the units, 
incl. to non-combustible items

   The protective grid of the 

intake must always be kept free 
of dirt and loose objects

   Never insert foreign objects into 

the unit

    The units must not be exposed 

to direct jets of water e.g. 
pressure washers, etc.

   All electrical cables for the 

units must be protected against 
damage (e.g. by animals etc.)

   Safety devices must not be 

bypassed or disabled

   According to its design, 

permanent, fixed unit 
installation is not intended for 
this unit type

Environmental 
protection and 
recycling

Содержание ATK 50-S

Страница 1: ...Edition GB I02 REMKO ATK 50 S Automatic oil heater with built in oil burner tank and exhaust gas connection Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...or on the unit itself Subject to modifications no liability accepted for errors or misprints Safety notes 4 Environmental protection and recycling 4 Unit description 5 Installation instructions 6 7 E...

Страница 4: ...ed by untrained personnel The following notes must be observed in full The power plug must be pulled out of the mains socket before maintenance and repair work The units may only be operated by person...

Страница 5: ...reset key 2 1 Unscrew the protective cap 1 2 Carefully press in the reset key 2 with a suitable tool 3 Screw the protective cap 1 back on again 4 Reset the automatic burner Operating sequence The sup...

Страница 6: ...ge due to inclement weather units installed outdoors must be adequately protected NOTE Overpressure and underpressure in the installation area should be avoided as this will inevitably lead to combust...

Страница 7: ...g the 1st BImSchV Units that are not expected to be operated for longer than 3 months in the same location are not subject to any approvals or monitoring as per the 1st BImSchV The units can be transp...

Страница 8: ...suitable and clean fuels may be used ATTENTION In the event of defects that endanger the operational safety of the units operation of the units must be discontinued immediately and the supervisor inf...

Страница 9: ...e of the units The units including combustion chamber and burner must be cleared of soot deposits dust and dirt after every heating period or according to the operating conditions The oil filters must...

Страница 10: ...alues 7 Following maintenance work refit all parts carefully in reverse order NOTE When positioning the baffle plate 7 always ensure that the aperture 5 is not obscured by a strut on the plate s s s C...

Страница 11: ...e pump run for extended periods without any fuel Never leave the units for extended periods with a pump that has run dry Exhaust gas analysis To perform the exhaust gas analysis the exhaust gas measur...

Страница 12: ...s Exploded view of the unit B 69 B 54 52 53 32 34 35 97 31 99 39 98 42 41 123 111 116 100 117 15 22 119 101 102 104 103 105 30 18 11 A 80 1 125 126 95 92 121 27 24 28 19 70 23 40 114 90 113 50 112 122...

Страница 13: ...40 STB support bracket 1103981 104 Connection nipple 1 4 1111674 41 Cable gland 1103982 105 Connection nipple 1 8 1111672 42 Counter nut 1103983 111 Fuel filter one way 1102146 50 Combustion chamber...

Страница 14: ...fuel pump and replace if necessary 9 The fuel tank is empty Fill the fuel tank with clean EL heating oil or diesel 10 The fuel filter is contaminated Replace the fuel filter 11 The nozzle is blocked...

Страница 15: ...n max 1 kW 0 85 Electrical protection provided by the customer A 10 Sound pressure level LpA 1m 2 dB A 74 Exhaust connection mm 150 Dimensions Length mm 1535 Width mm 650 Height mm 1005 Weight kg 102...

Страница 16: ...must be advisers to our customers in air conditioning and heating technology Customer service Our units operate precisely and reliably However in the event of a malfunction REMKO customer service is...