Connecting the units to 
the electrical power supply

1.   Move the operating 

switch to the "0" 
(Off) position.

2.   Connect the power plug to a 

properly installed 
and appropriately 
safeguarded 
230 V/50 Hz
mains socket.

Commissioning

The units must be checked 
for visible defects on the 
operating and safety devices as 
well as proper installation and 
correct electrical wiring before 
commissioning.

One person, who has been 
adequately trained in the handling 
of the units, must be tasked with 
operation and monitoring of the 
units.

   The units must installed to be 

stable in a horizontal position

   Ensure there is an adequate 

supply of combustion air

   Check that the inlet and outlet 

are free

   Prevent overpressure and 

underpressure in the installation 
area

   The fuel supply must be 

ensured with suitable fuel

   The fuel tank may only be filled 

when the unit is switched off.
Do not use biodiesel!

   Use only clean and suitable 

tanks for filling

NOTE

The exhaust gas values must 
be checked and/or adjusted 
by authorised and qualified 
technicians according to 
the local conditions.

NOTE

The electrical connection for 
the units must be made at a 
separate feed point with a residual 
current device in accordance with 
VDE 0100, Section 55.

NOTE

Only suitable and clean fuels 
may be used.

ATTENTION

In the event of defects that 

endanger the operational 

safety of the units, operation 

of the units must be 

discontinued immediately and 

the supervisor informed!

ATTENTION

In this operating mode, 

the fuel tank must always be 

filled with a basic quantity of 

heating oil.

There is no warranty claim 

for pump damage due to dry 

running!

NOTE

Paraffin formation can start 
at temperatures below 5°C. 
To avoid this appropriate 
preventative measures must 
be implemented, e.g. winter 
Diesel.

Ventilation only operation

In this switch position, the supply 
air fan runs permanently. 
The units can be used for air 
recirculation or ventilation 
purposes.

1.   Check the content of the fuel 

tank.

2.   Move the operating 

switch to the "II" 
(Ventilate) position.

Thermostatic regulation and 
heating operation are not possible 
in this operating mode.

Fuel filter

The fuel filter [

] must be checked 

for dirt or paraffin formation 
before the unit is started.

Paraffin formation with low 
outside temperatures.

Even at low temperatures, an 
adequate supply of flowing 
heating oil must be ensured.

   The in-built fuel pre-heating 

[

] is activated only when 

the power plug is connected 
to a functional mains socket 
and the ambient temperature is 
lower than 10°C

   It is not possible to rectify 

paraffin separation that 
has already occurred with 
the heating. If paraffin has 
already formed it is necessary 
to clean out the complete fuel 
system

Содержание ATK 50-S

Страница 1: ...Edition GB I02 REMKO ATK 50 S Automatic oil heater with built in oil burner tank and exhaust gas connection Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...or on the unit itself Subject to modifications no liability accepted for errors or misprints Safety notes 4 Environmental protection and recycling 4 Unit description 5 Installation instructions 6 7 E...

Страница 4: ...ed by untrained personnel The following notes must be observed in full The power plug must be pulled out of the mains socket before maintenance and repair work The units may only be operated by person...

Страница 5: ...reset key 2 1 Unscrew the protective cap 1 2 Carefully press in the reset key 2 with a suitable tool 3 Screw the protective cap 1 back on again 4 Reset the automatic burner Operating sequence The sup...

Страница 6: ...ge due to inclement weather units installed outdoors must be adequately protected NOTE Overpressure and underpressure in the installation area should be avoided as this will inevitably lead to combust...

Страница 7: ...g the 1st BImSchV Units that are not expected to be operated for longer than 3 months in the same location are not subject to any approvals or monitoring as per the 1st BImSchV The units can be transp...

Страница 8: ...suitable and clean fuels may be used ATTENTION In the event of defects that endanger the operational safety of the units operation of the units must be discontinued immediately and the supervisor inf...

Страница 9: ...e of the units The units including combustion chamber and burner must be cleared of soot deposits dust and dirt after every heating period or according to the operating conditions The oil filters must...

Страница 10: ...alues 7 Following maintenance work refit all parts carefully in reverse order NOTE When positioning the baffle plate 7 always ensure that the aperture 5 is not obscured by a strut on the plate s s s C...

Страница 11: ...e pump run for extended periods without any fuel Never leave the units for extended periods with a pump that has run dry Exhaust gas analysis To perform the exhaust gas analysis the exhaust gas measur...

Страница 12: ...s Exploded view of the unit B 69 B 54 52 53 32 34 35 97 31 99 39 98 42 41 123 111 116 100 117 15 22 119 101 102 104 103 105 30 18 11 A 80 1 125 126 95 92 121 27 24 28 19 70 23 40 114 90 113 50 112 122...

Страница 13: ...40 STB support bracket 1103981 104 Connection nipple 1 4 1111674 41 Cable gland 1103982 105 Connection nipple 1 8 1111672 42 Counter nut 1103983 111 Fuel filter one way 1102146 50 Combustion chamber...

Страница 14: ...fuel pump and replace if necessary 9 The fuel tank is empty Fill the fuel tank with clean EL heating oil or diesel 10 The fuel filter is contaminated Replace the fuel filter 11 The nozzle is blocked...

Страница 15: ...n max 1 kW 0 85 Electrical protection provided by the customer A 10 Sound pressure level LpA 1m 2 dB A 74 Exhaust connection mm 150 Dimensions Length mm 1535 Width mm 650 Height mm 1005 Weight kg 102...

Страница 16: ...must be advisers to our customers in air conditioning and heating technology Customer service Our units operate precisely and reliably However in the event of a malfunction REMKO customer service is...

Отзывы: