Connect the load pump of the second tank.
E
Second domestic hot water tank.
R
Connect the DHW sensor of the second tank.
Y
Connect the TELCOM remote vocal monitoring module.
(depending on its availability in your country).
U
Connecting the BUS cascade, VM.
Use a shielded cable connected on each side of the earth.
I
Connect the remote control (Package AD258/FM52).
Settings to be made for this type of installation
Parameters
Access
Settings to be made See chapter
INSTALLATION
Installer level
#SYSTEM
menu
EXTENDED
¼
If second tank connected:
S.AUX:
(1)
Installer level
#SYSTEM
menu
DHW
¼
specific to the installation", page
If a remote monitoring module is connected
to the 0-10V inlet on the terminal block:
IN 0-10V
Installer level
#SYSTEM
menu
NO
¼
specific to the installation", page
If a remote monitoring module is connected
to the 0-10V inlet on the terminal block:
I.TEL:
(2)
Installer level
#SYSTEM
menu
ANTIFR
¼
specific to the installation", page
(1) The parameter is only displayed if
INSTALLATION
parameter is set to
EXTENDED
.
(2) The parameter is only displayed if the parameter
IN 0-10V
is set to
OFF
.
iSense Pro DIN - AD280
4. Installation
12/04/2011 - 300025649-001-B
26