Regardless of what is done to the keys, the regulator
switches back to
CLASSIC
mode after 30 minutes.
5.5.2.
Setting the parameters specific to the
installation
1. Access the installer level: Press key
-
for around 5 seconds.
2. Select the menu
#SYSTEM
.
4
Turn the rotary button to scroll through the menus or
modify a value.
4
Press the rotary button to access the menu selected
or confirm a value modification.
¼
For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 31
3. Set the following parameters according to the connections made
to the PCBs:
Installer level - #SYSTEM menu
Parameter
Adjustment range Description
Factory setting Customer
setting
CIRC. B:
(1)
3WV
Connecting a circuit with 3-way valve ( For example:
Underfloor heating)
3WV
SWIM.P.
Using the circuit for pool management
DIRECT
Use of circuit in direct heating circuit
Check and set the heating curve if necessary. See
chapter:
¼
"Setting the heating curve", page
CIRC. C:
(1)
3WV
Connecting a circuit with 3-way valve ( For example:
Underfloor heating)
3WV
SWIM.P.
Using the circuit for pool management
DIRECT
Use of circuit in direct heating circuit
Check and set the heating curve if necessary. See
chapter:
¼
"Setting the heating curve", page
S.AUX:
(1)
DHW LOOP
Use as a domestic loop pump
DHW LOOP
PROGRAM.
Use as an independent programmable outlet
PRIMARY PUMP
The outlet
AUX PUMP
is active if a heating demand is
present on the secondary pump
DHW
Use of primary circuit of second DHW tank
FAILURE
The outlet
AUX PUMP
is active if a fault is detected
DHW ELEC
Used to control the electrical resistor according to the
timer programme on circuit AUX in summer mode
I.SYST
(1)
SYSTEM
The inlet sensor is used to connect the common flow
sensor of a cascade system
SYSTEM
STORAGE TANK
Hot water storage tank affected to heating only
DHW STRAT
Using the DHW tank with 2 sensors (top and bottom)
ST.TANK+DHW
Hot water storage tank affected to heating and
domestic hot water
(1) The parameter is only displayed if
INSTALLATION
parameter is set to
EXTENDED
(2) The parameter is only displayed if the parameter
IN 0-10V
is set to
OFF
1
1
2
2
r
c
STD
(
'
t
v
0
2
4
6
8
10
12
14
16
18
22
24
20
p
b
AUTO
x c
r
j
M
g
m
SUNDAY 11:45
5"
TEMP.: 68°
C002235-F-04
iSense Pro DIN - AD280
5. Operating the appliance
12/04/2011 - 300025649-001-B
34