38
569000203
1. Disconnect electrical power from the Unit.
2. Remove screw securing the hood, then lift the hood straight up to remove from the Unit.
3. Remove plug from the drop-in refrigeration assembly platform water fill hole.
4. Using a flashlight, inspect the ice water bath and ice bank for cleanliness. The ice water bath should be
clear and the ice bank should be free of foreign particles.
5. If cleaning of the water tank is necessary, refer to CLEANING WATER TANK in this section.
6. Fill the water tank with clean water until water runs out of the water tank overflow hose. USE
LOW-MINERAL-CONTENT WATER WHERE A LOCAL WATER PROBLEM EXISTS.
7. Install plug in the drop-in refrigeration assembly platform water fill hole.
8. Install Unit hood and secure with screw.
9. Connect electrical power to the Unit.
CLEANING WATER TANK
(see applicable Figure 9, 10 or 11)
1. Disconnect electrical power from the Unit.
2. Remove screw securing the hood, then lift the hood straight up to remove from the Unit.
3. Unplug the drop-in refrigeration assembly and electric dispensing valve power cords.
4. Unit with integral (built-in) carbonator.
A.
Shut off CO
2
and plain water supplies to the Unit.
B.
Disconnect carbonated water tank ground wire (green with yellow stripe) connector, protruding up
through hole in drop-in refrigeration assembly deck, from mating ground wire connector on top of the
refrigeration assembly deck.
C.
Disconnect two-conductor wiring harness connector from electrical terminals on top of the carbonated
water tank.
D.
Pull up on the carbonated water tank relief valve ring protruding up through hole in the drop-in
refrigeration deck (see Figure 11) to bleed off all pressure from the water tank.
E.
Disconnect plain water inlet and outlet lines from the carbonator water pump.
5. Extend the water tank drain hose to a waste container or floor drain. Remove plug from end of the drain
hose and allow the water tank to drain.
6. Allow the ice bank to melt. Hot water may be used to speed melting.
7. Very carefully, lift the drop-in refrigeration assembly up and out of the Unit.
CAUTION: Never use an ice pick or other instrument to remove ice from the drop-in
refrigeration assembly evaporator coils. Such practice can result in a punctured
refrigeration circuit.
8. Use a fiber brush and carefully clean mineral deposit build-up from the agitator motor shaft and the ice
bank sensing bulb.
9. Wash inside of the water tank and the drop-in refrigeration assembly evaporator coils, then rinse with clean
water.
Содержание Cornelius VANGUARD 245
Страница 7: ...2 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 29: ...24 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 48: ...43 569000203 FIGURE 16 WIRING DIAGRAM REMOTE OR INTEGRAL CARBONATOR UNIT WHT OR BLU BLK OR BRN ...
Страница 49: ...44 569030007 FIGURE 17 WIRING DIAGRAM DISPENSER P N 497306660WS WHT OR BLU BLK OR BRN ...
Страница 55: ...50 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 61: ......
Страница 68: ......
Страница 70: ...63 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 71: ...CORNELIUS INC CORPORATE HEADQUARTERS No 12 Xintai Road TEDA Tianjin P R C 300457 Tel 86 22 2529 0858 ...