CONNECTING PLAIN WATER SOURCE LINE TO CHILLED PLAIN WATER DISPENSING SYSTEM
(UNIT P/N 497306660WS)
(see Figures 2, and 9).
1. Route plain water source line from plain water source up to the Unit.
2. Route plain water line up under Dispenser, up behind Dispenser front access panel, and on to the plain
water solenoid valve on top of the refrigeration deck.
3. Connect plain water line to inlet of the plain water solenoid valve.
CONNECTING CO
2
SOURCE LINE (UNIT WITH INTEGRAL CARBONATOR)
(see Figures 5 or 6 and 11)
Proceed as follows to connect CO
2
source line to Unit with integral (built-in) carbonator.
1. Route CO
2
source line, connected to an adjustable CO
2
regulator, up to the Unit.
2. Connect CO
2
source line to CO
2
check valve on end of the Unit CO
2
inlet tube labeled “CO
2
”.
SEALING UNIT BASE TO COUNTERTOP
NOTE: An alternate arrangement to avoid sealing the Unit to the countertop as described below, would
be to install the optional Leg Kit (P/N 560000126) to raise the Dispenser up off the countertop.
To comply with NSF International (NSF) requirements within the United States, the Unit base must be sealed to
the countertop and all access holes in the Unit base must be sealed with permagum or an equivalent sealant
material. Proceed as follows to seal the Unit base to the countertop.
1. Tilt the Unit up to expose the bottom of it’s base.
2. Liberally apply silastic sealant (such as Dow Corning RTV 731 or equivalent) on Unit base bottom edges.
NOTE: Do not move the Unit after positioning or the seal from the base to the countertop will be
broken.
3. Lower the Unit into operating position on the countertop to complete seal from the Unit base to the
countertop.
4. Apply additional sealant around bottom of the Unit base. The seal must have a minimum radius of 1/2-inch
(12.7 MM) to prevent crevices and to ensure a complete seal.
5. Seal all access holes to the Unit base with permagum or an equivalent sealant material.
CO
2
REGULATORS ADJUSTMENTS
WARNING: CO
2
displaces oxygen. Strict attention
must
be observed in the prevention of
CO
2
(carbon dioxide) gas leaks in the entire CO
2
and soft drink system. If a CO
2
gas leak is
suspected, particularly in a small area,
immediately
ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
2
gas will experience
tremors which are followed rapidly by loss of consciousness and suffocation.
Содержание Cornelius VANGUARD 245
Страница 7: ...2 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 29: ...24 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 48: ...43 569000203 FIGURE 16 WIRING DIAGRAM REMOTE OR INTEGRAL CARBONATOR UNIT WHT OR BLU BLK OR BRN ...
Страница 49: ...44 569030007 FIGURE 17 WIRING DIAGRAM DISPENSER P N 497306660WS WHT OR BLU BLK OR BRN ...
Страница 55: ...50 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 61: ......
Страница 68: ......
Страница 70: ...63 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 71: ...CORNELIUS INC CORPORATE HEADQUARTERS No 12 Xintai Road TEDA Tianjin P R C 300457 Tel 86 22 2529 0858 ...