31
569000203
5. Press “CANCEL/POUR” switch (see Figure 12) and hold for four-seconds.
NOTE: 10-fluid ounces (296 ml) of water should have been dispensed into the volume cup for
sugar-based drinks and 7.6-fluid ounces (225-ml) for sugar-free based drinks.
6. If the water volume is correct, proceed with step 10. If the water flow rate is not correct, proceed with
step 7.
7. Remove plastic cover from the water flow regulator labeled “WATER”.
8. Turn the dispensing valve water flow control adjusting screw CLOCKWISE to increase or
COUNTERCLOCKWISE to decrease the water flow rate.
NOTE: One (1) turn of the water flow control adjusting screw will change the water flow rate
approximately 2-fl. ounces (59-ml) per 4-second draw.
9. Install plastic cover on the dispensing valve water flow control.
10. Install dispensing valve top cover and secure with screw.
11. Install dispensing valve portion control cover by sliding the portion control cover down into place on the top
cover.
12. Re-connect syrup supply to the dispensing valve
CHECKING WATER VOLUME (PORTION-CONTROL DISPENSING VALVES)
Dole Dispensing Valve.
1. Remove front cover from the dispensing valve by pulling out on the bottom of the cover.
2. Remove top cover from the dispensing valve by loosening screw on front of the valve, then remove the
cover.
3. Turn syrup shutoff valve (right-side shutoff valve) to the “CLOSED” (extreme COUNTERCLOCKWISE)
position.
NOTE: The dispensing valve water shutoff valve
must
be in the fully “OPEN” position. The shutoff
valves
are not
to be used for calibrating. They
are
to be used for shutting off the syrup and/or water
supply.
4. At the same time, press and hold the “S” (small) and the “XL” (extra large) dispense switches
(see Figure 12) on the dispensing valve front cover until the LED indicator light on the cover starts blinking.
A blinking LED indicates the portion control “set mode“ has been activated.
5. Place volume cup under the dispensing valve nozzle.
6. Press dispense switch labeled “S” (small) and dispense until water volume noted in the following
CHART
1
(for sugar-base or sugar-free diet drink) is dispensed, then release the switch.
CHART 1
DISPENSE SWITCH
CUP SIZE
WATER ONLY LEVEL
4.75:1 (SUGAR-BASE
SYRUP DRINK)
WATER ONLY LEVEL
5.25;1 (SUGAR-FREE
SYRUP DRINK)
“S” (small)
12-fl oz. (355 ml)
6.96-fl. oz. (206 ml)
7.07-fl. oz. (209 ml)
“M” (medium
16-fl. oz. (472 ml)
9.60 fl. oz. (284 ml)
9.76-fl. oz. (289 ml)
“L” (large)
21 fl. oz. (621 ml)
13.79 fl. oz. (408 ml)
14.02-fl. oz. (414 ml)
“XL” (extra large)
32 fl. oz. (446 ml)
20.42 fl. oz. (604 ml)
20.76-fl. oz. (614 ml)
Содержание Cornelius VANGUARD 245
Страница 7: ...2 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 29: ...24 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 48: ...43 569000203 FIGURE 16 WIRING DIAGRAM REMOTE OR INTEGRAL CARBONATOR UNIT WHT OR BLU BLK OR BRN ...
Страница 49: ...44 569030007 FIGURE 17 WIRING DIAGRAM DISPENSER P N 497306660WS WHT OR BLU BLK OR BRN ...
Страница 55: ...50 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 61: ......
Страница 68: ......
Страница 70: ...63 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 71: ...CORNELIUS INC CORPORATE HEADQUARTERS No 12 Xintai Road TEDA Tianjin P R C 300457 Tel 86 22 2529 0858 ...