17
569000203
ADJUSTING CARBONATOR CO2
REGULATOR
Unit Requiring Connection To a Remote Carbonator.
Adjust CO
2
regulator (regulator controls carbonator CO
2
pressure
)
as instructed in manual provided with the
remote carbonator.
Unit With Integral (Built–in Carbonator.
Adjust CO
2
regulator (regulator controls Unit built-in carbonator CO
2
pressure
)
to a nominal 80-psi (5.5 BARS).
CO
2
inlet pressure to the carbonator must not exceed 125-psi (8.6 BARS).
ADJUSTING SYRUP SUPPLIES SECONDARY CO
2
REGULATORS
Sugar Syrup Supplies Secondary CO
2
Regulators.
Adjust syrup tanks secondary CO
2
regulator to a minimum of 45-psi (3.1 BARS).
Low–Calorie (Diet) Syrup Tank Secondary CO
2
regulator.
Adjust low-calorie (diet) syrup tank secondary CO
2
regulator to 10-psi (0.69 BAR) for syrup lines 30-feet (9.1 M)
in length. Syrup lines longer than 30-feet in length may require a slightly higher setting of 12-psi (0.82 BAR)
maximum. Excessive CO
2
pressure may cause low-calorie syrup carbonation resulting in foam.
Syrup Pumps (Bag–In–Box System) CO
2
or Compressed Air Regulator.
Adjust the syrup pumps CO
2
or compressed air regulator to 70–PSI (4.82 BARS).
DO NOT EXCEED
MAXIMUM PRESSURE SPECIFIED ON THE SYRUP PUMPS.
FILL WATER TANK AND START THE REFRIGERATION SYSTEM
(see applicable Figure 9, 10 or 11)
1. Make sure plug in end of the water tank drain hose is secure.
NOTE: Use a low-mineral-content water where a local water problem exists.
2. Remove plug from drop-in refrigeration assembly platform water fill hole. Fill the water tank with clean
water until water flows out of the water tank overflow hose. USE A LOW-MINERAL-CONTENT WATER
WHERE A LOCAL WATER PROBLEM EXISTS.
3. Install plug in the water fill hole.
4. Unit with integral (built-in) carbonator–Activate plain water and CO
2
supplies to the Unit. Make sure CO
2
inlet pressure to the carbonator is adjusted to a nominal 80-psi (5.5 BARS) CO
2
inlet pressure to the
carbonator must not exceed 125-psi (8.6 BARS).
WARNING: The Unit must be electrically grounded to avoid possible fatal electrical shock
or serious injury to the operator. The power cord is equipped with a three-prong plug. If a
three-hole (grounded) electrical outlet is not available, use an approved method to ground
the Unit.
5. Place dispensing valves keyed lock-out switch on side of the Unit in the ‘‘OFF’’ position.
6. 60 Hz Units.
Make sure Unit power switch (if applicable) is in “ON” position.
7. Plug the Unit power cord into an electrical outlet with the proper electrical requirements. The compressor,
condenser fan motor, and agitator motor will start and begin forming an ice bank. When full ice bank has
been formed, the compressor and condenser fan motor will stop but the agitator motor will continue to
operate circulating ice water bath in the water tank.
Содержание Cornelius VANGUARD 245
Страница 7: ...2 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 29: ...24 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 48: ...43 569000203 FIGURE 16 WIRING DIAGRAM REMOTE OR INTEGRAL CARBONATOR UNIT WHT OR BLU BLK OR BRN ...
Страница 49: ...44 569030007 FIGURE 17 WIRING DIAGRAM DISPENSER P N 497306660WS WHT OR BLU BLK OR BRN ...
Страница 55: ...50 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 61: ......
Страница 68: ......
Страница 70: ...63 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 71: ...CORNELIUS INC CORPORATE HEADQUARTERS No 12 Xintai Road TEDA Tianjin P R C 300457 Tel 86 22 2529 0858 ...