30
569000203
NOTE:
Do not
confuse syrup and water shutoff valves with dispensing valve flow control adjusting
screws.
NOTE: The dispensing valve water shutoff valve
must
be in the fully “OPEN” position.
LED INDICATOR LIGHT
CANCEL/POUR SWITCH
FIGURE 12. PORTION CONTROL COVER
5. Position volume cup under the dispensing valve nozzle.
6. Dispense from the regular dispensing valve for four-seconds or press “CANCEL/POUR” switch (portion
control dispensing valve) as shown in Figure 12 and hold for four-seconds.
NOTE: 10-fluid ounces (296 ml) of water should have been dispensed into the volume cup for
sugar-based drinks and 7.6-fluid ounces (225-ml) for sugar-free based drinks.
7. If the water volume is correct, proceed with step 8. If the water flow rate is not correct, proceed with step 9.
8. Turn dispensing valve water flow control adjusting screw to the right (CLOCKWISE) to increase water flow
rate or to the left (“COUNTERCLOCKWISE”) to decrease the water flow rate.
NOTE: One (1) turn of the water flow control adjusting screw will change the water flow rate
approximately 2-fluid ounces (59-ml) per 4-second draw.
9. Repeat steps 2 through 7 for each dispensing valve until all valves are checked and/or calibrated (as
required). The water flow rate check is complete.
10. Turn syrup shutoff valve (right-side shutoff valve) to the “OPEN” (extreme CLOCKWISE) position.
11. Install top cover on the dispensing valve and secure with screw.
12. Install front cover on the dispensing valve.
13. Re-connect syrup supply to the dispensing valve
CC–1 Dispensing Valve.
1. Disconnect syrup supply from the dispensing valve the water flow rate check will be performed on.
2. Remove applicable dispensing valve portion control cover by sliding the cover up and off the top cover.
3. Remove dispensing valve top cover by loosening screw securing the cover, then lift cover up and off the
valve.
4. Position volume cup under the dispensing valve nozzle.
Содержание Cornelius VANGUARD 245
Страница 7: ...2 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 29: ...24 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 48: ...43 569000203 FIGURE 16 WIRING DIAGRAM REMOTE OR INTEGRAL CARBONATOR UNIT WHT OR BLU BLK OR BRN ...
Страница 49: ...44 569030007 FIGURE 17 WIRING DIAGRAM DISPENSER P N 497306660WS WHT OR BLU BLK OR BRN ...
Страница 55: ...50 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 61: ......
Страница 68: ......
Страница 70: ...63 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 71: ...CORNELIUS INC CORPORATE HEADQUARTERS No 12 Xintai Road TEDA Tianjin P R C 300457 Tel 86 22 2529 0858 ...