19
569000203
INSTALLING FRONT ACCESS PANEL, SPLASH GUARDS, DRIP TRAY, AND CUP REST
(see applicable Figure 9, 10 or 11)
1. Place front access panel in position on the Unit.
2. Place right-side SPLASH GUARD (item 8) in position on the Unit . Secure splash guard and front access
panel to the Unit with two screws that were removed when removing the front access panel.
LEAVE
SCREWS LOOSE FOR THE TIME BEING
.
3. Place left-side SPLASH GUARD (item 9) in position on the Unit . Secure splash guard and front access
panel to the Unit with other two screws that were removed when removing the front access panel.
LEAVE
SCREWS LOOSE FOR THE TIME BEING
.
4. Install DRIP TRAY (item 2) in drip tray holder as follows:.
IMPORTANT: Before installing Dispenser (Unit P/N 497306660WS) front access panel, make sure the
two-wire electrical wiring harness (see Figure 9) with spade clip terminals on it’s end (intended for
connection to the push-button plain water dispense switch on the drip tray support) is hanging down
out bottom of the Dispenser. This wiring harness
must
be connected to the plain water dispense
switch before installing the drip tray in the drip tray support.
5. Hold DRIP TRAY (item 2) up in position above the drip tray holder.
6. Connect drip tray drain hose to the drip tray and secure with DRAIN HOSE CLAMP (item 13).
7. Place the drip tray so that the two splash guard steps rest on the drip tray edge, then tip back of the drip
tray down and place it’s back edge up under bottom of the loosely installed front access panel.
8. When the drip tray is in this position, work the front corners of the drip tray down until the drip tray sits in
it’s proper position on the the drip tray holder.
9. Tighten all four screws securing the front access panel.
10. Using a silastic sealant (such as Dow Corning RTV 731 or equivalent), seal cracks on outsides of the
splash guards where they enter the drip tray holder.
11. Using a silastic sealant (such as Dow Corning RTV 731 or equivalent), Seal cracks on insides of the splash
guards where the drip tray and the splash guards surfaces meet. Also seal front edge of the drip tray where
it sets on the drip tray holder.
NOTE: Connection of drip tray drain hose to a permanent drain is recommended. Drip tray drain hose
routed to a waste container
is not
recommended due to sanitation and cleaning problems.
The drip tray drain hose
must
be attached to the drain to allow a 3-inch air gap between the drain and
the end of the hose. All connections
must
comply with local plumbing codes and health codes.
12. Preferably, route the lower end of the drip tray drain hose and connect it to a permanent drain.
13. Place CUP REST (item 1) in the drip tray.
CUP HOLDER
(OPTIONAL)
DRIP TRAY
DRIP TRAY HOLDER
CUP REST
STRAW HOLDER
(OPTIONAL)
SPLASH
GUARD
SPLASH
GUARD
PLAIN WATER DISPENSE SWITCH
(DISPENSER 497306660ws)
FIGURE 8. DRIP TRAY INSTALLATION
Содержание Cornelius VANGUARD 245
Страница 7: ...2 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 29: ...24 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 48: ...43 569000203 FIGURE 16 WIRING DIAGRAM REMOTE OR INTEGRAL CARBONATOR UNIT WHT OR BLU BLK OR BRN ...
Страница 49: ...44 569030007 FIGURE 17 WIRING DIAGRAM DISPENSER P N 497306660WS WHT OR BLU BLK OR BRN ...
Страница 55: ...50 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 61: ......
Страница 68: ......
Страница 70: ...63 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 71: ...CORNELIUS INC CORPORATE HEADQUARTERS No 12 Xintai Road TEDA Tianjin P R C 300457 Tel 86 22 2529 0858 ...