26
569000203
ADJUSTMENTS
CO
2
REGULATORS ADJUSTMENTS
WARNING: CO
2
displaces oxygen. Strict attention
must
be observed in the prevention of
CO
2
(carbon dioxide) gas leaks in the entire CO
2
and soft drink system. If a CO
2
gas leak is
suspected, particularly in a small area,
immediately
ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
2
gas will experience
tremors which are followed rapidly by loss of consciousness and suffocation.
Adjusting Carbonator Primary CO
2
Regulator.
UNIT REQUIRING CONNECTION TO A REMOTE CARBONATOR.
Adjust CO
2
regulator (regulator controls carbonator CO
2
pressure
)
as instructed in manual provided with the
remote carbonator.
UNIT WITH INTEGRAL (BUILT-IN) CARBONATOR.
Adjust CO
2
regulator (regulator controls Unit built-in carbonator CO
2
pressure
)
to a nominal 80-psi. (5.5 BARS)
CO
2
inlet pressure to the carbonator must not exceed 125-psi. (8.6 BARS)
Adjusting Syrup Supplies CO
2
Regulator.
SUGAR SYRUP TANKS SECONDARY CO
2
REGULATOR
Adjust syrup tanks secondary CO
2
regulator to a minimum of 45-psi (3.1 BARS).
LOW-CALORIE (DIET) SYRUP TANK SECONDARY CO
2
REGULATOR
Adjust low-calorie (diet) syrup tank secondary CO
2
regulator to 12-psi (0.82 BAR) maximum.
SYRUP PUMPS (BAG-IN-BOX SYSTEM)
Adjust the syrup pumps CO
2
regulator to 70-psi (4.82 BARS).
DO NOT EXCEED MAXIMUM CO
2
PRESSURE
SPECIFIED ON THE SYRUP PUMPS.
ADJUSTING DISPENSING VALVES FOR WATER FLOW RATE
Dole Dispensing Valve.
The dispensing valves adjustable water flow regulators are factory adjusted and should require no further
adjustment. If readjustment should become necessary, proceed as follows:.
1. Disconnect syrup supply from the dispensing valve the water flow rate check will be performed on.
2. Remove front cover from the dispensing valve by pulling out on the bottom of the cover.
3. Remove top cover from the dispensing valve by loosening screw on front of the valve, then remove the
cover.
4. Turn syrup shutoff valve (right-side shutoff valve) to the “CLOSED” (extreme COUNTERCLOCKWISE)
position.
Содержание Cornelius VANGUARD 245
Страница 7: ...2 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 29: ...24 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 48: ...43 569000203 FIGURE 16 WIRING DIAGRAM REMOTE OR INTEGRAL CARBONATOR UNIT WHT OR BLU BLK OR BRN ...
Страница 49: ...44 569030007 FIGURE 17 WIRING DIAGRAM DISPENSER P N 497306660WS WHT OR BLU BLK OR BRN ...
Страница 55: ...50 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 61: ......
Страница 68: ......
Страница 70: ...63 569000203 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 71: ...CORNELIUS INC CORPORATE HEADQUARTERS No 12 Xintai Road TEDA Tianjin P R C 300457 Tel 86 22 2529 0858 ...