Checking Oil Level
The oil level in the gearbox must be maintained at the recommended level to ensure
efficient operation. Too much oil causes heating from the oil churning. Too little oil
causes heating from lack of lubrication.
To check the oil level:
1. Remove the plug on the side of the gearbox nearest the front of the GrainVac (see
Figure 5.24 Plugs for Walterscheid (red) and Star (black) Gearboxes
2. The oil level should be high enough to allow the oil to come up to the lower edge of
the front side hole when mounted at 45° angle. If required, add oil by removing the
vented fill plug on the top of the gearbox and pouring oil into that hole.
3. Replace
the
plug(s).
Cleaning Reservoir Breather
The vented fill plug on top of the gearbox contains the breather for the reservoir (see
Figure 5.24).
Important:
This breather must function properly to prevent a pressure build-up that will cause the
seals to leak. The breather should be cleaned annually and more frequently in very
dusty, dirty operating conditions.
To clean the breather:
1. Remove the vented fill plug.
2. Soak the plug in good solvent for 1 hour.
3. Blow out the breather passage of the plug with compressed air to remove any dirt
accumulation to ensure that it is open.
SIDE PLUG
(CHECK LEVEL)
VENTED FILL PLUG
Содержание GrainVac VR12
Страница 30: ...3 TRANSPORT REM GRAINVAC VR12 3 2 ATTACHING TRANSPORTING GRAINVAC WITH TRACTOR OR TRUCK 30 9000 00 0042 R3...
Страница 70: ...5 MAINTENANCE REM GRAINVAC VR12 5 4 MAINTENANCE PROCEDURES 70 9000 00 0042 R3 Figure 5 23 Gearbox Removal...
Страница 86: ...6 SERVICE REM GRAINVAC VR12 6 6 DRUM REMOVAL MAINTENANCE 86 9000 00 0042 R3...
Страница 90: ...7 STORAGE REM GRAINVAC VR12 7 3 REMOVING FROM STORAGE 90 9000 00 0042 R3...