INSTALLATION INSTRUCTIONS FOR AIR BATHS

!

   

!

  

Do not attempt to remove the foam or board from the bottom of the tub. Doing so may        

        cause damage and will void warranty. 

1.   Never handle the bath by the blower, piping or other equipment.
2.   Make sure the manifold and airlines are protected when moving the tub into the house.
3.   An access panel of at least 16” x 14” must be provided for the blower for any future servicing.
4.   The blower must not be insulated and must have sufficient air space to permit proper    

 

operation. Surrounding ambient air temperature should be between 72º F and 86º F. 

5.   The heating element on your blower heats the air blown into the tub to prevent the  

 

 

water from cooling too quickly. It will not, under any circumstances, reheat or    

 

 

maintain the temperature of the bath water.

6.   The area underneath and around the tub must be cleaned thoroughly before finalizing  

 

 

installation to prevent any particles from entering the blower or being blown into the air 

jets. 

7.   Before filling the tub, clean installation debris and dirt from the interior of the tub. If  

 

necessary, use the soft brush attachment of a vacuum cleaner.

8.   Fill tub and test for proper operation and leaks. Note: The blower must be plugged into    

 

a GFCI protected outlet.

Note: All air baths are equipped with an automatic drying cycle. The blower will turn on for 1-2 minutes 

approximately 20 minutes after the air system is turned off. This drying cycle cannot be cancelled. Any 

attempt to cancel this cycle only resets the countdown timer. 

INSTALLATION INSTRUCTIONS FOR INTEGRAL SKIRTED TUBS

All Reliance Integral Skirted tubs come with several standard features. Standard features include an 

integral molded front skirt, integral three-sided tile flange and a pre-leveled foam base. These tubs are 

designed to be installed in a three-wall alcove.

1. Slide tub into installation location. Check to ensure that the tub is level to allow for proper drainage. If 

the tub is not level, do not continued with the installation. A self leveling compound may be used to level 

the subfloor. Read and follow all manufacturers directions. 

2. Carefully drill 1/8” holes through the tile flange at each stud location. Secure to stud with screws, 

being careful not to over-tighten as this might cause the acrylic to crack or chip. Do not attempt to drive 

nails throught the integral flange. 

See ‘Tile Flange - Factory Installed’ on previous page.

Содержание R6632CRA

Страница 1: ...N U A L I N S T A L L A T I O N G U I D E E f f e c t i v e J u l y 1 2 0 1 1 Installer This booklet must be given to the product owner Please note important information below Distributor Name City St...

Страница 2: ...any opening IMPORTANT Locate and note your serial number on the cover of this manual for any future service needs OWNER S MANUAL AND INSTALLATION GUIDE Thank you for choosing a Reliance bath You have...

Страница 3: ...hydrotherapy bath since medication may induce drowsiness affect heart rate blood pressure and circulation DANGER To reduce the risk of injury enter and exit the bath slowly WARNING Never operate elect...

Страница 4: ...ranty 12 13 Commercial Warranty 14 15 A T T E N T I O N I N S T A L L E R Access must be provided to each pump and or electrical component on your tub The access panel must have a minimum size of 16 x...

Страница 5: ...op of bowl K Inside bowl length at bottom of bowl L Flange edge depth M Top flange width N Drain center to edge of flange O Allow 1 2 to 1 to D for wet bedding P Pre leveled frame height Adds 1 2 3 to...

Страница 6: ...NTENDED AND WARRANTIED FOR INDOOR USE ONLY TEST PROCEDURES 1 Place the tub on a flat surface such as the driveway 2 Seal the drain with tape 3 Fill tub to overflow and allow tub to stand for five minu...

Страница 7: ...b bottom It is recommended to use a plastic sheet barrier on top of and underneath the bedding compound Carefully lower tub into place Shift tub side to side to settle into compound The tub will not d...

Страница 8: ...ends Quickrete Sand Mix to fill void between the bottom of the tub and floor If your tub was ordered with the pre leveled foam option no bedding compound is necessary Note If your floor is not complet...

Страница 9: ...attachment of a vacuum cleaner 8 Fill tub and test for proper operation and leaks Note The blower must be plugged into a GFCI protected outlet Note All air baths are equipped with an automatic drying...

Страница 10: ...cating the possibility of electric shock Do not use this unit Disconnect the unit and have the problem corrected by a qualified electrician before using 2 Every Reliance whirlpool or air bath is suppl...

Страница 11: ...opening 4 Do not operate this tub without the guard over the suction fitting water intake The guard is a safety device that reduces the potential hazard of hair or body entrapment Keep hair and body a...

Страница 12: ...to increase the possibility of bacteria growth within the system 8 Bubble bath should only be used sparingly The action of the system will greatly increase the amount of bubbles The system must also...

Страница 13: ...contact with nail polish nail polish remover Wintergreen oil dry cleaning solution lacquer thinners gasoline pine oil etc 4 Remove dust and dry dirt with a soft damp cloth 5 Clean grease oil paint or...

Страница 14: ...problem A The on off control may have been unplugged during installation Check that the on off control is connected to the blower and the blower is plugged into a working receptacle Check that the gr...

Страница 15: ...ructions Products containing strong natural or chemical dyes may discolor the jets and or controls on your tub Check the label to ensure the products are safe for acrylic or plastics and always use ac...

Страница 16: ...nsequential damage loss of time inconvenience incidental expenses labor or material charges or any other costs related to the application of this warranty Warranty Limitations Your warranty is void if...

Страница 17: ...r to install bed the unit properly allowing clear access for service Unit must be water tested prior to final enclosure Failure to do so will void warranty Damage occuring to the unit during installat...

Страница 18: ...mailed to MTI Baths in order for this warranty to become effective Warranty Limitations Your warranty is void if unit is not water tested and inspected prior to final enclosure Our warranty does not c...

Страница 19: ...r to install bed the unit properly allowing clear access for service Unit must be water tested prior to final enclosure Failure to do so will void warranty Damage occuring to the unit during installat...

Страница 20: ...Baths Inc 670 N Price Road Sugar Hill GA 30518 800 783 8827 770 271 8228 Fax 800 438 8827 reliancebaths com Email info reliancebaths com Copyright 2014 by MTI Whirlpools Inc Modification Rights Reserv...

Отзывы: