background image

Flash Updates

C-7

Performing a Flash Update with HyperTerminal

1.

In the main menu (

Figure 4.5

), press 

3

 to flash upgrade.

For connected MDI drives, you can only update the firmware in the converter. The 
screen in 

Figure C.11 

will immediately appear.

For connected DPI drives, a menu appears (

Figure C.10

) for you to select the 

device that you want to update.

After you select a device by typing its number, a line appears to confirm that you 
selected the right device (for example, “You have chosen to update -- 0 > 
PowerFlex 70 EC”) and the following text appears:

2.

If the flash update can be completed safely, type 

Y

. The letter “C” repeatedly 

appears. It is the Xmodem prompt and continues to appear until you send a binary 
file.

Important:

Press Ctrl + X to cancel a flash update procedure.

3.

Select 

Transfer > Send File

 to display the Send File screen (

Figure C.12

).

4.

Click 

Browse

 and navigate to the flash file.

5.

Double-click the file. Its name appears in the Filename box (see 

Figure C.12

).

Flash Upgrade. Enter Number for Selection.

0 > PowerFlex 70 EC

1 > LCD Module

2 > This 1203-USB

5 > 20-COMM-D

Figure C.10 – Example DPI Flash Menu

To update the Flash memory, you need a terminal program 

capable of downloading a binary file using the XMODEM protocol 

and a Flash update file from Rockwell Automation. When you 

press 'Y' to signal that you are ready to proceed, the 

terminal program will start displaying the letter 'C'. This 

signals the XMODEM protocol that the download may proceed. You 

then have one minute to start the transfer. Press CTRL-X to 

cancel an update started by mistake. Are you ready to proceed? 

(Y/N)

Figure C.11 – Flash Menu

!

ATTENTION:

Risk of injury or equipment damage exists. When you 

perform a flash update, the drive will fault if it is receiving control I/O from 
the converter. Verify that the drive has stopped safely or is receiving 
control I/O from an alternate source before beginning a flash update.

!

ATTENTION:

Risk of equipment damage exists. If you interrupt a flash 

procedure that is updating boot code, the device may become inoperable. 
To prevent this damage, follow the instructions provided with the new 
firmware file and do not interrupt a flash procedure while boot code is 
being flashed.

Содержание 1203-USB

Страница 1: ...Instruction Manual USB Converter 1203 USB D2 3559...

Страница 2: ...ed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written...

Страница 3: ...Converter 3 2 3 3 Installing the USB Drivers 3 3 3 4 Installing V S Utilities 3 6 3 5 Removing the Converter 3 6 Chapter 4 Configuring the Converter 4 1 Configuration Tools 4 1 4 2 Using the DPI Class...

Страница 4: ...II USB Converter User Manual Appendix A A 1 Appendix B B 1 Appendix C C 1 Appendix D D 1 Glossary...

Страница 5: ...istance from Reliance Electric If you have any questions or problems with the products described in this instruction manual contact your local Reliance Electric sales office For technical assistance y...

Страница 6: ...1 2 USB Converter User Manual...

Страница 7: ...liance Electric product implementing DPI SP600 LiquiFlo 2 0 and GV6000 or MDI MD60 and MD65 The converter uses the full duplex RS 232 DF1 protocol 2 1 Components Topic Page Components 2 1 Features 2 2...

Страница 8: ...re The converter is flash upgradeable to take full advantage of new firmware features as they become available Table 2 1 Components of the Converter Item Part Description Computer Cable Port The USB c...

Страница 9: ...2 4 1 Equipment Shipped with the Converter When you unpack the converter verify that the package includes 2 4 2 User Supplied Equipment To configure the converter you must use one of the following to...

Страница 10: ...t when you remove or reset the converter Determine how your drive will respond before removing or resetting a connected converter Table 2 2 Quick Start Steps Step Action Refer to 1 Review the safety p...

Страница 11: ...DPI Drive and Computer Figure 2 3 Connecting the Converter to a MDI Drive and Computer Pocket PC Laptop orDesktop Computer DPI Drive 1203 USB Converter 20 OIM H10 Cable USB Cable MDI Drive Pocket PC L...

Страница 12: ...leshooting Figure 2 4 Status Indicators on the Converter Table 2 3 Status Indicator Descriptions Item Status Indicator Normal State Description Diamond Flashing Green Converter is connected to a compa...

Страница 13: ...nnect the converter to the computer Of the two remaining cables use the 20 OIM H10 cable to connect the converter to a DPI drive or the 22 OIM H10 cable to connect the converter to a MDI drive For a l...

Страница 14: ...oing to be installed for a period of time it must be stored in an area where it will not be exposed to a corrosive atmosphere 1 Connect the converter to the drive Figure 3 3 using the appropriate cabl...

Страница 15: ...ill display the Found New Hardware Wizard screen Install the drivers for the 1203 USB and USB serial port on your computer by following the procedure described in Installing the USB Drivers on page 3...

Страница 16: ...tomatically searches for and loads the 1203 USB driver from the inserted CD 3 Keep the V S Utilities CD inserted in the computer On the V S Utilites Setup screen click Close 4 After the 1203 USB drive...

Страница 17: ...With the Install the software automatically Recommended radio button selected Figure 3 7 click Next The computer automatically searches for and loads the USB Serial Port driver from the inserted V S...

Страница 18: ...are 3 5 Removing the Converter 1 Disconnect the cable from the drive and then from the converter To disconnect the cable press on the cable latch and then pull it out 2 Disconnect the USB cable from t...

Страница 19: ...converter parameters Important The RS 485 serial port on MDI drives does not need to be configured before using the converter MDI communications are configured automatically 19 2K baud and 8 N 1 Topic...

Страница 20: ...4 2 LED OIM Quick Start Step Key s Example Screens 1 Press ALT and then Sel Device to display the Device Screen 2 Press the Up Arrow or Down Arrow to scroll to the 1203 USB converter Letters represen...

Страница 21: ...ss the Up Arrow or Down Arrow to scroll to 1203 USB 4 Press Enter to select the converter A parameter database is constructed and then a menu for the 1203 USB converter is displayed 5 Edit the paramet...

Страница 22: ...ties is shipped with the 1203 USB Converter Table 4 4 Using the OIM Step Key s Example Screens 1 Power up the drive Then plug the OIM into the drive The Parameters menu for the drive will be displayed...

Страница 23: ...In the System Properties window click on the Hardware tab and then click Device Manager c In the Device Manager menu tree expand the Port COM LPT group The assigned COM port is shown in parenthesis a...

Страница 24: ...ablish the initial USB connection to the converter using a computer running HyperTerminal terminal emulation software provided with most Windows operating systems Important The following instructions...

Страница 25: ...display the COM Properties screen Figure 4 4 7 Select the settings shown in Figure 4 4 8 Click OK A blank HyperTerminal workspace appears Important Select File Save to save the HyperTerminal configur...

Страница 26: ...igure 4 5 Main Menu Table 4 5 Key Description In the main menu keys 1 3 select a menu option In the parameter screen keys 0 9 enter a value Display the main menu or abort changes to a parameter Scroll...

Страница 27: ...ely reset When you select Set Defaults the converter will set all converter parameters to their factory default values After performing a Set Defaults select Reset Module so that the new values take e...

Страница 28: ...4 10 USB Converter User Manual...

Страница 29: ...tatus Figure 5 1 Topic Page Understanding the Status Indicators 5 1 Converter Diagnostic Items 5 4 Viewing and Clearing the Event Queue 5 5 Viewing and Clearing DFI Communication Statistics 5 8 Troubl...

Страница 30: ...drive Solid Green Converter is operating and is or was transmitting control I O No action required Removing or resetting the converter will cause a fault in the drive For DPI drives only a Soft Logou...

Страница 31: ...igure the computer software to use the same port rate as the converter Flashing Green Converter is receiving data from the computer No action required Table 5 4 TX Status Indicator Status Cause Correc...

Страница 32: ...the Product Specific Reference being transmitted to the drive by the converter 4 Common Logic Sts Present value of the Common Logic Status being received from the drive by the converter 5 Prod Logic...

Страница 33: ...Cmd Present value of the Logic Command being transmitted to the drive by the converter 5 Logic Sts Present value of the Logic Status being received from the drive by the converter 6 Feedback Present v...

Страница 34: ...her peripheral with the same port number is already in use EEPROM Sum Flt The EEPROM in the converter is corrupt Host Sent Reset The DPI drive issued this because it was reset Message Timeout The DPI...

Страница 35: ...F4 Host Timeout A timeout condition on Msg to Host F5 Slave Timeout A timeout condition on Msg to Slave F6 Master Timeout A timeout condition on Msg to Master F7 Serial Timeout A timeout on Serial 23...

Страница 36: ...converter parameters that store DF1 data DF1 Packets Sent 04 and DF1 Packets Rcvd 05 Refer to Appendix B Converter Parameters 5 4 2 To clear DF1 data counters 1 Access the parameters in the converter...

Страница 37: ...V S Utilities If you are using a different configuration tool refer to its instructional information HyperTerminal 1 Select File Properties and then click Configure 2 Select the new baud rate and the...

Страница 38: ...ower cycle the drive to which the converter is connected Then do one of the following HyperTerminal Connect to the drive through the converter Then simultaneously press the Ctrl and P keys as your ini...

Страница 39: ...2 Agency Certification A 3 Network side Protocol Port Rate Data Bits Parity Stop Bits Flow Control Error Universal Serial Bus USB 115 2 kbps 8 None 1 None CRC or BCC Auto Detected Drive side Protocol...

Страница 40: ...ing Atmosphere Important The converter must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas vapors or dust If the converter is not going to be installed for...

Страница 41: ...be terminated as described on page A 2 Note This is a product of category C2 according to IEC 61800 3 In a domestic environment this product may cause radio interference in which case supplementary mi...

Страница 42: ...A 4 USB Converter User Manual...

Страница 43: ...if set to Ready Resets the converter if set to Reset Module Restores the converter to its factory default settings if set to Set Defaults This parameter is a command It will be reset to 0 Ready after...

Страница 44: ...to the value of DF1 Packets Sent 04 Default 0 Minimum 0 Maximum 4294967295 Type Read Only 06 Interface Mode Sets the interface operating mode Auto The converter will automatically run DPI if connected...

Страница 45: ...rformed Default 0 Ready Values 0 Ready 1 Reset Module 2 Set Defaults Type Read Write Reset Required No 03 Clear DF1 Counts No action if set to Ready Resets the DF1 statistical parameter DF1 Packets Se...

Страница 46: ...thru mode the converter node address must match the address of any drive on the network Each network drive address set using Comm Node Addr 104 must be unique In any case the RTU DSI address is a deci...

Страница 47: ...for example HyperTerminal In this manual we show how to use HyperTerminal Record parameter values in the device that will be flashed Updates may reset parameters to their default settings Ensure that...

Страница 48: ...ll be different than those shown 1 Visit the following Reliance Electric web site to obtain the appropriate firmware update for the device http www ab com support abdrives webupdate At this web site c...

Страница 49: ...between the drive connected to the 1203 USB converter and the computer For this procedure please see Using V S Utilities on page 4 4 4 In the V S Utilities application window Figure C 3 click on the...

Страница 50: ...rmation screen Then click the Details tab to show a screen Figure C 4 with the device s firmware revision information 6 In the Details tab screen click the Flash Update button to open the Select Flash...

Страница 51: ...t for this example 2 003 19 App Then click Next to continue The Confirm Flash Update warning screen Figure C 6 appears 8 Click FLASH to start the flash update Figure C 7 If an advisory dialog box appe...

Страница 52: ...re C 8 Click Close to exit the Flash Update Completed screen The Device Firmware Changed dialog box Figure C 10 will appear 10 V S Utilities will prompt you to reconnect since the device may have chan...

Страница 53: ...r Number for Selection 0 PowerFlex 70 EC 1 LCD Module 2 This 1203 USB 5 20 COMM D Figure C 10 Example DPI Flash Menu To update the Flash memory you need a terminal program capable of downloading a bin...

Страница 54: ...log box appears and reports the progress of the download When it is complete the message Operation Complete appears Important Keep the device powered for 15 seconds after the operation has completed 8...

Страница 55: ...ed Verify that you have selected the Xmodem protocol in the Send File screen Verify that the new file is on your computer hard drive Do not attempt to flash from a removable storage device or a networ...

Страница 56: ...C 10 USB Converter User Manual...

Страница 57: ...efer to the following section in Chapter 4 Configuring the Converter that corresponds to the drive software tool you are using Using V S Utilities on page 4 4 Configuring the Drive Parameters When set...

Страница 58: ...converter node address do not use a value higher than 77 octal 2 For each remaining drive to be networked set drive parameter Comm Node Addr 104 to a unique address Setting Comm Loss Action For each...

Страница 59: ...elow to note the settings for each drive to be networked Network Drive Number Address Setting for Drive Parameter Drive Addr Cfg 104 Comm Fault Setting for Drive Parameter Comm Loss Action 105 1 2 3 4...

Страница 60: ...r network refer to the network wiring example shown in Figure D 2 Connect the first MDI Class drive Drive 1 on the network to the 1203 USB converter using an AK U0 RJ45 SC1 splitter cable Connect its...

Страница 61: ...lass drives up to 32 drives total on the RTU Master network daisy chain them together using the same type of cable and terminal block adapters connected into Port 2 on the bottom of each respective dr...

Страница 62: ...diagram for using the AK U0 RJ45 TB2P terminal block connectors Accessing Drives on the RTU Master Network Using one of the Reliance Electric drive software tools enables you to monitor configure and...

Страница 63: ...twork to display the Network Connection Node Selection screen Figure D 6 3 Select the Multiple radio button Then enter the node address for the first network drive for this example 1 and the node addr...

Страница 64: ...ity Then expand each node to display the connected drive and 1203 USB converter representation Figure D 8 Important 1203 USB converter representation appears for each drive in the menu tree even thoug...

Страница 65: ...Using RTU Master Mode D 9...

Страница 66: ...D 10 USB Converter User Manual...

Страница 67: ...lly update firmware on printed circuit boards The tool takes advantage of the growing use of flash memory electronic erasable chips across industrial control products Converter The 1203 USB converter...

Страница 68: ...LASH or the built in flash capability of V S Utilities version 4 06 or higher Hold Last When communications are disrupted for example a cable is disconnected the converter and drive can respond by hol...

Страница 69: ...e messages and whether they can log in for control S Status Indicators Status indicators are LEDs that are used to report the status of the converter There are three status indicators on the converter...

Страница 70: ...Glossary 4 USB Converter User Manual...

Страница 71: ...r RTU Master mode using V S Utilities D 4 connecting cables 3 2 definition Glossary 1 dimensions A 2 installing 3 2 parameters for DPI drives B 1 to B 5 power consumption A 1 removing 3 6 resetting 4...

Страница 72: ...s indicators M MDI definition Glossary 2 peripheral Glossary 2 product Glossary 2 MDI drives Glossary 2 mechanical specifications A 2 N NVS Non Volatile Storage definition Glossary 3 parameters in 4 1...

Страница 73: ...1 terminal emulation software using 4 6 tools see equipment TX Status Indicator 5 3 U update see flash update USB converter driver installation 3 3 serial port driver installation 3 5 Using 4 2 Using...

Страница 74: ...Index 4 USB Converter User Manual...

Страница 75: ......

Страница 76: ...Email support drives ra rockwell com Online www ab com support abdrives Trademarks not belonging to Rockwell Automation are property of their respective companies Publication D2 3559 May 2006 Copyrig...

Отзывы: