9.5 Information & Maintenance
9.5.1 I&M0, 0xAFF0
The measuring system supports the I&M-Function
“I&M0 RECORD”
(60 byte), like
PROFIBUS “Profile Guidelines Part 1”.
I&M-Functions specify the way how the device specific data, like a nameplate, must
be created in a device.
The I&M record can be read with an acyclic read service.
The record index is 0xAFF0, the read service is sent to module 1 / submodule 1.
The received 60 bytes have the following contents:
Contents
Number of bytes
Manufacturer specific (block header type 0x20)
6
Manufacturer_ID
2
Order-No.
20
Serial-No.
16
Hardware revision
2
Software revision
4
Revision state
2
Profile-ID
2
Profile-specific type
2
I&M version
2
I&M support
2
9.6 Behavior of the measuring system outputs
Condition
Safety-related data
NON-Safety-related data
IOPS = BAD
Values are set to 0
Values are set to 0
Disconnection
(abort)
Values are set to 0
Values are set to the last value
before the connection was
interrupted
Supply Voltage
ON
Values are initialized to 0
Values are initialized to 0