Printed in the Federal Republic of Germany
TR-Electronic GmbH 2013, All Rights Reserved
01/17/2019
TR - ECE - BA - DGB - 0102 - 09
Page 125 of 175
Attr.-ID
Access NV
Name
Data type Description
Default
Page
100
Get
V
Position Value
Extended
ULINT
Position value, 64 Bit
-
101
Set
NV
1)
Total Measuring
Range
ULINT
Total measuring range in
steps
16777216
102
Set
NV
1)
Number of
Revolutions -
Numerator
UDINT
Number of revolutions
numerator
4096
103
Set
NV
1)
Number of
Revolutions -
Denominator
UDINT
Number of revolutions
denominator
1
104
Set
NV
2)
Preset Value
Extended
ULINT
Preset value (64 bit)
0
105
Set
NV
1)
TR-Parameter in use
BOOL
Defines which scaling
parameters are in use
0
106
Get
V
Temperature Value
INT
Temperature value
in °C
107
Set
NV
1)
Temperature Value
Format
ENGUNIT
Temperature format
0x1200: °C
108
Set
NV
3)
Temperature Low
Limit
INT
Minimum temperature
value
0
109
Set
NV
3)
Temperature High
Limit
INT
Maximum temperature
value
0
110
Set
-
Additional Vendor-
Parameter 1
UDINT
Reserved for further
function
-
111
Set
-
Additional Vendor-
Parameter 2
UDINT
Reserved for further
function
-
112
Set
V
Accept Parameter
USINT
Save parameters in non-
volatile memory
0
113
Get
V
Encoder Firmware
Number
STRING
Firmware number of the
measuring system
-
114
Get
V
Encoder Firmware
Version
STRING
Firmware version of the
measuring system
-
Table 15: Position Sensor, Overview of the instance attributes
1)
This attribute only takes effect after executing service code 0x16
save
or attribute 112
Accept Parameter
.
2)
This attribute is immediately active and saved.
3)
This attribute is immediately active but not saved to non-volatile memory.