Parameterization
TR-Electronic GmbH 2013, All Rights Reserved
Printed in the Federal Republic of Germany
Page 148 of 175
TR - ECE - BA - DGB - 0102 - 09
01/17/2019
7.4.3.33 Attribute 107, Temperature Value Format
Temperature Value Format
defines the output unit of “Attribute 106,
” and the input unit of “Attribute 108, Temperature Low Limit” and
“Attribute 109, Temperature High Limit”.
ENGUNIT
Value
Unit
Default
0x1F04
degree Celsius [°C]
X
0x1F05
degree Fahrenheit [°F]
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x6B
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #107
This attribute only takes effect after executing service code 0x16
save
or attribute 112
Accept Parameter
.
7.4.3.34 Attribute 108, Temperature Low Limit
Temperature Low Limit
defines the minimum value of the temperature with the
unit that is defined in “Attribute 107, Temperature Value Format” it is standardly °C. If
this value falls
below in “Attribute 47, Warnings” the depending warn bit (13) is set to
high.
INT, Default: - 20 °C
Temperature Low Limit
Byte 0
Byte 1
2
7
up to 2
0
2
15
up to 2
8
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x6C
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #108
To save this attribute permanently the attribute 112
Accept Parameter
or service
code 0x16
save
must be executed.