Parameterization
TR-Electronic GmbH 2013, All Rights Reserved
Printed in the Federal Republic of Germany
Page 130 of 175
TR - ECE - BA - DGB - 0102 - 09
01/17/2019
7.4.3.7.2 Attribute 17, Total Measuring Range in Measuring Units
Total Measuring Range in Measuring Units
defines the
total number of
steps
of the measuring system before the measuring system restarts at zero.
UDINT
Total Measuring Range
Byte 0
Byte 1
Byte 2
Byte 3
2
7
up to 2
0
2
15
up to 2
8
2
23
up to 2
16
2
31
up to 2
24
Access
Set / Get
Lower limit
16 steps
Upper limit
4 294 967 295 (32 Bit)
Default
16777216
At measuring ranges ≥ 32 bit, the “Attribute 101, Total Measuring Range” on page
142 must be used.
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x11
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #17
This attribute only takes effect after executing service code 0x16
save
or attribute 112
Accept Parameter
.
The actual upper limit for the measurement length to be entered in steps is dependent
on the measuring system version and can be calculated with the formula below. As
the value "0" is already counted as a step, the end value = measurement length in
steps - 1.
Total measuring range = Steps per revolution * Number of revolutions
Formula 1: General Scaling parameter