7.4.3.35 Attribute 109, Temperature High Limit
Temperature Low Limit
defines the maximum value of the temperature with the
unit that is defined in “Attribute 107, Temperature Value Format” it is standardly °C. If
this value is exceeded in “Attribute 47, Warnings” the depending warn bit (14) is set to
high.
INT, Default: + 85 °C
Temperature Low Limit
Byte 0
Byte 1
2
7
up to 2
0
2
15
up to 2
8
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x6D
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #109
To save this attribute permanently the attribute 112
Accept Parameter
or service
code 0x16
save
must be executed.
7.4.3.36 Attribute 110, Additional Vendor-Parameter 1
Reserved for further functions.
7.4.3.37 Attribute 111, Additional Vendor-Parameter 2
Reserved for further functions.
7.4.3.38 Attribute 112, Accept Parameter
Accept Parameter
complies to the service code 0x16 (Save Paramter) and saves
the measuring system parameter into the non-volatile memory (EEPROM).
With writ
e access ≠ 0 all changed attributes are stored permanently and the
acceptance of changed values for the instance attributes is performed.
Attr.-ID
112
Data type
USINT
Access
Set / Get
Lower limit
0
Upper limit
255
Default
0