REINHARDT
System- und Messelectronic GmbH
Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196 - 934100
MWS_55_e.indb Page 69
geändert am 26.10.2017 von DO
Manual MWS 55 / MWS 88 / MWS 10 and Sensors 55
Sensor
Group
Sensor-
Pos
Description
Sensoroptions
Sensor-ID
Datasource
Compensation
Special
48
RS232
RS232-Sensor 8
!G14
49
RS232
RS232-Sensor 9
!G15
50
RS232
RS232-Sensor 10
!G16
51
RS232
RS232-Sensor 11
!G17
52
RS232
RS232-Sensor 12
!G18
53
RS232
RS232-Sensor 13
!G19
54
RS232
RS232-Sensor 14
!G20
55
RS232
RS232-Sensor 15
!G21
56
RS232
RS232-Sensor 16
!G22
57
Internal
Frequency lightning
!I1
0: Counter (Raw val.)
1: Frequency (Hz)
2: Windspd. (1 x)
3: Windspd. (12 x)
10: Counter Resetval.
Μicro: Pin 57
(F-input)
58
Internal
K8
K9
K10
Frequency Windspeed
!I2
0: Counter (Raw val.)
1: Frequency (Hz)
2: Windspd. (1 x
3: Windspd. (12 x)
10: Counter Resetval.
WG
WS
WD
Μicro: Pin 46
59
Internal
K11
K12
Frequency Precipitation
!I3
0: Counter (Raw val.)
1: Frequency (Hz)
2: Windspd. (1 x)
3: Windspd. (12 x)
10: Counter Resetval.
RE
RD
Μicro: Pin 116
60
Internal
Internal AD-Converter, Channel 1 (AD0_0)
(*or Timer/Counter 4
!I4)
*0: Counter (Raw val.)
*1: Frequency (Hz)
*2: Windspd. (1 x)
*3: Windspd. (12 x)
*10: Counter Resetval.
Μicro: Pin 13
(i.e. Tacho signal fan)
61
Internal
Internal AD-Converter, Channel 2 (AD0_1)
62
Internal
Internal AD-Converter, Channel 3 (AD0_2)
63
Internal
Internal AD-Converter, Channel 5 (VIN)
!PL
Sensoroptionen 1..3
[since V3.0209]
0: AD-CVT value
1: Error counter
2: last error code
3: no Batt. voltage
64
Virtual
K1
RTC (RealTimeClock: Time, Date)
P0: Date 2char
P1: Date 2char US
P4: Date 4char
P5: Date 4char US
65
Virtual
Time
0: 0 (Time)
1: Seconds
2: Minutes
3: Hours
4: Min. * 60 + Sec.
5: Hrs
*3600+Min*60+Sec
10: Second odd
66
Virtual
Date
0: 0 (Time)
1: Day (1..31)
2: Month (1..12)
3: Year (4stellig)
4: Day of week (0..6)
5: Day of year (1..365)
10: Day of year odd
----------------------------
P0: Date 2char
P1: Date 2char US
P4: Date 4char
P5: Date 4char US
67
Virtual
K27
Altitude
OH
68
Virtual
69
Virtual
70
Virtual
71
Virtual
72
Virtual
Output1
!V9
Reed at Signalmodule (Pin120 - Steuer7)
73
Virtual
Output2
!V10
Pad at Signalmodule (Pin110 - Steuer6)
74
Virtual
Output3
!V11
Pad at Signalmodule (Pin108 - Steuer5)
75
Virtual
Output4
!V12
Pad at Signalmodule (Pin104 - Steuer4)
76
Virtual
Output5
!V13
Green at Signalmodule (Pin101 - Steuer3)
77
Virtual
Output6 / Heating 1
!V14
Yellow at Signalmodule (Pin94 - Steuer2)
78
Virtual
Output7 / Heating 2
!V15
Red at Signalmodule (Pin91 - Steuer1)
79
Virtual
Output8 / Fan
!V16
+5V at Signalmodule (Pin54 - Steuer8)
80
Virtual
K22
Barometric Pressure
!V17
S1 = TD, S2 = FE, S3 = Altitude, S4= DR
0: Intern.formula
1: DWD (+TE/FE)
2: BMP180 (simple)
DB