MWS_55_e.indb Page 28
Manual MWS 55 / MWS 88 / MWS 10 and Sensors 55
geändert am 26.10.2017 von DO
REINHARDT
System- und Messelectronic GmbH
Fax: 08196/7005 and 1414 email:
http://www.reinhardt-wetterstationen.de
All Reinhardt weather stations will send back each received command in brackets with CF and
LF before processing the command, i.e. <?U>, to verify that the command has been received.
On harddisk, a data file is created every month with a format which is similar to that of the
transmitted data. The data files receive the extension .MWS
Example : The file of March 2015 is named 03_2015.MWS.
In case of missing data (cause by power fail, etc.) the software writes data with measuring values
of -99999 to ensure integrity of the time axis. The software construes these values (-99999 and
-99997) as missing data and creates measurement gaps in the graphical displays.
3.9.1 Data access onto the SD-card
The MWS 55 allows data access onto the SD-card with a shell similar to a DOS-window with
different commands.
To perform, send the command *shell in a terminal software like hyperterminal, putty or any
other terminal program. The weather station then switches into the command window.
PLEASE NOTE THAT THE STATION DOES NOT STORE ANY DATA INTO THE LOGGER
WHILE IT IS IN THE COMMAND WINDOW !
Paths must be separated with slash (/) not with backslash (\).
To exit the shell type EXIT and then press the ENTER key.
The shell can be used to delete weather data files which are not needed any longer, for storing
calibration settings or for checking the free space on the SD-card.