Manual MWS 55 / MWS 88 / MWS 10 and Sensors 55
geändert am 26.10.2017 von DO
REINHARDT
System- und Messelectronic GmbH
Fax: 08196/7005 and 1414 email:
http://www.reinhardt-wetterstationen.de
SC: SciFlags
Bit 8 = SCI_FRM_ERR -> Frame-Error (is deleted after request)
Bit 7 = SCI_OVR_ERR -> Overrun-Error (is deleted after request)
Bit 6 = SCI_PAR_ERR -> Parity-Error (is deleted after request)
Bit 5 = Reserved
Bit 4 = Reserved
Bit 3 = SCI_TX_ENA -> Sender active
Bit 2 = SCI_RX_ENA -> Receiver active
Bit 1 = TERMINATION -> Instruction termination (Carriage-Return) received
TZ: Time-Zone (UTCtoRTC), -12 ... +13,
(AUTO) shows that automatic DST switching is active,
(DST) shows, that daylight savings time is set
AT: Attenuation (not used)
HZ: Value for activation of heating device (not used)
TA: TK_calibration-Temp. (after I-Temp.raw value), 0-255
KM: Compressing value (not used)
IF: Admin-Flags (see !F)
PF: Power-Flags (undocumented)