18
REGULUS - STDC E Controller - www.regulus.eu
F 2 - Statistics
Menu
„2. Statistics”
is used for function control and
long-term monitoring of the system.
The menu is closed by pressing
„esc”
or selecting
„Exit statistics”
.
For analysis of the system data it is essential that time is set accurately on the controller.
Please note that the clock does not continue to run if the mains voltage is interrupted, and must therefore be
reset. Incorrect time set in the controller may result in data being deleted, recorded incorrectly or overwritten.
F 2.1 - Operating hours
Display of operating hours of the solar pump connected to the controller; various time ranges are available
(day-year).
F 2.2 - Average temperature difference
Δ
T
Display of the average temperature difference between the reference sensors of the solar system with the
consumer switched on.
F 2.3 - Heat output
Display of the approximate heat output of the solar system. This menu can be selected, however, only when
the function of Heat quantity is activated under F 7.7.
F 2.4 - Graphic overview
This function provides a clearly-organized display of the data listed under F2.1 to F 2.3 as a bar graph. Various
time ranges are available. The two left-hand keys can be used to page through the data.
F 2.5 - Error messages
Display of the last 20 errors occurring in the system with indication of date and time.
F 2.6 - Reset / Clear
Resetting and deleting the individual analyses. The function
„All statistics”
clears all analyses but not the
error messages.
Caution