51
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
MAINTENANCE
3)
Check for evidences of excessive
condensation, such as water droplets forming
in the inner liner, and subsequently dripping
out the joints, Continuous condensation can
cause corrosion of caps, pipe, and fi ttings.
It may be caused by having excessive
lateral runs, too many elbows, and exterior
portions of the system being exposed to cold
weather.
4)
Inspect joints, to verify that no pipe
sections or fi ttings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.
GOLD-PLATED &
BRASS LOUVERS
OR TRIM
The 24 carat gold plated or brass fi nish on the
trim requires little maintenance, and need only
be cleaned with a damp cloth. DO NOT use
abrasive materials or chemical cleaners, as
they may harm the fi nish and void the warranty.
Clean any fi ngerprints off before turning the
unit on. If the top louvers start to discolour,
check the door gasket seal and replace if
necessary.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagrams under Log
Installation.
Note: Improper positioning of logs may create
carbon build-up and will severely alter
the unit's performance which is not
covered under warranty.
THERMOPILE/
THERMOCOUPLE
1)
Open the bottom louvers.
2)
Loosen the thermocouple or thermopile with
a 7/16" wrench.
3)
Disconnect thermocouple by loosening nut
from the valve with a 9mm wrench. Dis-
connect thermopile by loosening 2 screws
marked TP on the valve.
4)
Drop the thermocouple or thermopile down
from the bracket and pull it out of the unit.
5)
Reinstall the new ones in reverse order.
GLASS GASKET
If the glass gasket requires replacement use
5/8" fl at glass gasket for the Bay Front (Part
# 936-243) and a tadpole glass gasket for the
Flush Front (Part # 936-155).
DOOR GLASS
Your FPI fi replace is supplied with high tem-
perature, 5 mm Neoceram ceramic glass that
will withstand the highest heat that your unit will
produce. If your glass requires cleaning, we
recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials. Do not clean the glass
when hot.
In the event that you break your glass by impact,
purchase your replacement from an authorized
FPI dealer only, and follow our step-by-step
instructions for replacement.
WARNING: Do not operate the appli-
ance with the glass panels removed,
cracked or broken. Replacement of
the glass panels should be done
by a licensed or qualifi ed service
person.
BAY GLASS REPLACEMENT
1)
Remove the door from the unit and place
on a soft surface to prevent scratching.
2)
Remove the nuts holding the glass clips in
place and remove.
3)
Replace the glass.
The glass must have
gasketing around it.
5)
Reverse the previous steps, replace the
glass clips and fasten with the nuts but
do not over tighten, as this can break the
glass.
6)
Replace door on the stove and check the
seal.
CAUTION: Wear gloves when
removing damaged or broken
glass.
FLUSH GLASS REPLACEMENT
Remove the fl ush door front, see the "Stand-
ard Flush Door" section. Remove the 4 glass
clips from each corner. Slide in the new
replacement glass. Push the 4 glass clips
back onto the frame.
The glass must have
gasketing around it.