23
FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
INSTALLATION
Rigid Pipe Adaptor
Pipe Length
Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
24" Pipe
Length
Adj.Pipe Length
11" - 14-5/8"
90 Elbow
o
Horizontal
Termination
Cap
Wall Thimble
Vinyl Siding
Standoff (Optional)
RIGID PIPE VENTING SYSTEMS
Horizontal or Vertical Terminations
The minimum components required for a basic horizontal termination are:
1 Horizontal
Termination
Cap
1 90
o
Elbow
1 Rigid
Pipe
Adaptor
1 Wall
Thimble
1 Length of pipe to suit wall thickness (see chart)
Wall thickness is measured from the back standoffs to the inside mounting
surface of termination cap. For siding other than vinyl furring strips may be
used, instead of the vinyl siding standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure
to outside surface of wall without siding and add 2 inches.
Alternate
Horizontal Ter-
mination Caps
(Must be used with all Rigid Piping)
Flat Wall Installation
Wall Thickness
(inches)
Vent Length Required
(inches)
4" - 5-1/2"
6"
7" - 8-1/2"
9"
10" - 1-1/2"
12"
9" - 14-1/2"
11" - 14-5/8" Adj. Pipe
15" - 23-1/2"
17" - 24" Adj.
Corner Installation
Wall Thickness
(inches)
Vent Length Required
(inches)
3-1/4" - 6-3/4"
11" - 14-5/8" Adj. Pipe
7-3/4" - 16-1/4"
17" - 24" Adj. Pipe
7-1/4" - 8-3/4"
6" + 12"
9" + 9"
4-1/4" - 5-3/4"
6" + 9"
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent , Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
TM
and FPI
Riser is acceptable with all systems.
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
The FPI AstroCap
TM
and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent
®
Direct Vent ,
American Metal Products Ameri Vent Direct Vent, Security Secure Vent
®
, Selkirk Direct-Temp. AstroCap
TM
is a proprietary trademark of FPI Fireplace
Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.