FPI P36-4 Zero Clearance Direct Vent Gas Fireplace
INSTALLATION
VERTICAL TERMINATION - CO-LINEAR FLEX SYSTEM
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex run-
ning the full length of the chimney. See the
"Venting Arrangements" section for minimum
and maximum heights.
Masonry chimneys may take various contours which the fl exible liner will accommodate. However,
keep the fl exible liner as straight as possible
, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter
Outer
Pipe
Inner
Pipe
Adapter
510-994 Flue
Adaptor
FPI Cabinet and/or Flat Wall Mantles may
be used in these applications ensuring
that clearances to combustibles are
maintained.