background image

Models: P33NG3-R
 P33LPG3-R

Owners &

Installation

PLEASE KEEP THESE INSTRUCTIONS 

FOR FUTURE REFERENCE

 Man

ual

02/04/10

918-537a

WARNING:  

Improper installation, adjustment, alteration, 
service or maintenance can cause injury or 
property damage. Refer to this manual. For 
assistance or additional information consult 
an authorised installer, service agency or the 
gas supplier.

FOR YOUR SAFETY

Do not store or use gasoline or other 
fl ammable vapours and liquids in the vicinity 
of this or any other appliance.

Installation and service must be performed 
by an authorised installer, service agency or 
the gas supplier.

P33 Gas Log Fireplace

FOR YOUR SAFETY

What to do if you smell gas:

 

Do not try to light any 
appliance

 

Do not touch any electrical 
switch: do not use any 
phone in your building.

 

Immediately call your gas 
supplier from a neighbour's 
phone. Follow the gas 
supplier's instructions.

 

If you  cannot reach your 
gas supplier, call the fi re 
department.

LISTINGS AND CODE APPROVALS

These gas appliances have been tested in 
accordance with AS4553, NZS 5262 and 
have been certifi ed by the Australian Gas 
Association for installation and operation as 
described in these Installation and Operating 
Instructions.

Your unit should be serviced annually by 
an authorised service person.

Содержание P33LPG3-R

Страница 1: ...rformed by an authorised installer service agency or the gas supplier P33 Gas Log Fireplace FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplierfromaneighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire departmen...

Страница 2: ...warmth and charm of a wood fireplace at the flick of a switch The model P33 has been approved by the Australian Gas Association for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fire...

Страница 3: ...r Flex System 22 Horizontal Terminations 24 Vertical Terminations 25 Gas Line Installation 25 Pilot Adjustment 26 Gas Pipe Pressure Testing 26 S I T Valve Description 26 Conversion Kit 433 968 from NG to LPG 27 Conversion Kit 434 967 from NG To ULPG 29 Conversion Kit 434 965 from NG To ULPG 31 Optional Brick Panels 33 Log Set Installation 33 Standard Flush Door 35 Flush Louvers 35 Wall Thermostat ...

Страница 4: ... DATA BADGE NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one Electrical 240VAC 50Hz 1 0 amp max Serial Number 918 308c N2134 Regency Gas Fireplace 266 Gas Type NG LPG ULPG Model Gas Consumption 23 7 23 5 20 3 Manifold Pressure 0 95 Injector Size 1x 1x 54 1x 55 P33 NG P33 LPG P33 ULPG mj mj mj kPa kPa ...

Страница 5: ...ceoflocalcodes with the current National Electrical Code ANSI NFPA 70 or CSA C22 1 Canadian Electrical Code 3 See general construction and assembly instructions The appliance and flue should be enclosed 4 This appliance must be connected to the specified flue and termination cap to the outside of the building envelope Never flue to another room or inside a building Make sure that the flue is fitte...

Страница 6: ...equate clearances for servic ing 3 The appliance must be installed on a flat solid continuous surface e g wood metal concrete Thismaybethefloor orraisedup on a platform to enhance its visual impact If the appliance is going to be installed on carpeting combustible linoleum tile or other combustible material other than wood flooring theappliancemustbeinstalledona metal or wood panel extending the f...

Страница 7: ...umdistances unless otherwise stated Amajor cause of chimney related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and flue system be installed only in accordance with these instructions Clearance to Combustibles from Back 0 0mm Side 0 0mm Floor 0 0mm NOTE Theminimumfloorclearancemustbemain tainedfromthetopsu...

Страница 8: ...terial e g drywall plus ceramic tiles to allow the finished surface to be flush with the front of the unit Total facing thickness canvaryfrom1 2 13mm to1 1 4 32mm thick 2 Frame in the enclosure for the unit with framing material FRAMING AND FINISHING TheHeatWaveDuctKithasdifferentclear anceandframingrequirements checkthe HeatWave manual for details 16 1 2 419mm Minimum 4 102mm 3 76mm 1 1 2 38mm 30...

Страница 9: ...al 1 Mount Top Facing Support using the 3 supplied screws into the three pre punched screwholesonthetopfrontoftheunit Adjust support to desired facing material depth 2 Mount Side Nailing Strip using the 3 sup plied screws into the three pre punched screw holes at the front sides of the unit Adjust support to desired facing material thickness UNIT ASSEMBLY PRIOR TO INSTALLATION INSTALLATION FLUEING...

Страница 10: ... air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I see table below NOTES I For mechanical air inlets in...

Страница 11: ...ia flexible liner 2 ft length 2 4 dia flexible liner 2 ft length 3 spring spacers 3 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 drill point stainless steel 4 Alternate Horizontal Termination Caps Wherever necessary due to external location of cap the AstroCap can be replaced with the FPI Riser Flue Termination Cap or the Dura Vent ...

Страница 12: ... assembly by applying Mill Pac to the 4 100mm inner collar of the terminationand slippingthe4 100mm liner over it at least 1 3 8 35mm Fasten with the3screws drillingpilotholeswillmakethis easier Apply Mill Pac or high temperature silicone to the 6 7 8 175mm flex pipe and slip it over the 6 7 8 outer collar of the flue terminal at least 1 3 8 35mm and fasten with the 3 screws 4 Separatethe2halvesof...

Страница 13: ...th of pipe to suit wall thickness see chart For siding other than vinyl furring strips may be used instead of the vinyl siding standoff to create a level surface to mount the flue terminal The Terminal must not be recessed into siding If a Vinyl Siding Standoff is required it must be used with vinyl siding measure to outside surface of wall without siding and add 2 inches The Regency AstroCapTM is...

Страница 14: ...Black 991 High Wind Termination Cap Vertical 980 Vertical Termination Cap 984 Horizontal Square Termination Cap 985 Horizontal Square High Wind Termination Cap 982 Snorkel 14 Rise Termination Cap 981 Snorkel 36 Rise Termination Cap 940 Wall Thimble Support Box 941 Cathedral Ceiling Support Box 3951 Brass Trim for Wall Thimble Ceiling Support 963 Firestop Spacer 943 Flashing 0 12 6 12 943S Flashing...

Страница 15: ...les Note Must use optional flue adapter when using Simpson Dura Vent pipe Part 510 994 FLUEING ARRANGEMENTS VERTICAL TERMINATIONS SIMPSON Dura Vent DIRECT FLUE GS SYSTEM NG LPG ULPG The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using one 90o elbow with Simpson Dura Vent Direct Flue GS flue systems for NG LPG and ULPG ...

Страница 16: ...NG The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with Simpson Dura Vent Direct Flue GS flue systems for LPG ULPG and NG Maximum two 45o elbows allowed Flue must be supported at offsets Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles ...

Страница 17: ...bustibles Horizontal flue must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A flue guard should be used whenever the ter mination is lower than the specified minimum or as per local codes Note Regency DirectFlueSystem Flex is onlyapprovedforhorizontaltermina tions Minimum Simpson Dura Vent Center Line Minimum Flex Kit Center Line Importan...

Страница 18: ...ional flue adapter Part 510 994 when using Simpson Dura Vent pipe Maintain clearances to combustibles Horizontal flue must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A flue guard should be used whenever the termination is lower than the specified minimum or as per local codes Note Regency Direct Flue System Flex is only approved for hor...

Страница 19: ... E 1 5m Min 2 1m Max F 1 8m Min 2 4m Max Option H V H H1 H2 With these options max totalpipelength is 30 feet with min of 11 feet total vertical and max 9 feet total horizontal Please note min 1 foot between 90o e l b o w s i s required A 0 3m Max 0 3m Min 0 9m Max B 0 6m Max 0 9m Min 1 5m Max C 0 9m Max 1 5m Min 1 8m Max D 1 2m Max 2 1m Min 2 1m Max E 1 5m Max 2 7m Min 2 4m Max F 1 8m Max 3 3m Mi...

Страница 20: ...0 6m 1 5m 0 9m C 0 9m 1 8m 1 2m D 1 2m 2 1m 1 5m E 1 5m 2 4m 1 8m Vertical Flueing with Two 2 90o Elbows With these options max total pipe length is 30 feet with min of 6 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is re quired Option H H1 V Max Min A 0 6m 0 6m B 0 9m 0 9m C 1 2m 1 2m D 1 5m 1 5m E 1 8m 1 8m Withtheseoptions max total pipelengthis3...

Страница 21: ... and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required Vertical Flueing with Three 3 90o Elbows Option H V H H1 V V1 Max Min Max Min A 0 3m 0 3m 0 9m 0 9m B 0 6m 0 6m 1 2m 1 5m C 0 9m 0 9m 1 5m 2 1m D 1 2m 1 2m 1 8m 2 7m E 1 5m 1 5m 2 1m 3 3m With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 7 feet total horizontal Please...

Страница 22: ... Flueing Arrangements on next page for minimum and maximum heights Masonry chimneys may take various contours which the flexible liner will accommodate However keep the flexible liner as straight as possible avoid unnecessary bending The Air Intake pipe must be attached to the inlet air collar of the termination cap Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 ...

Страница 23: ...ions with Co linear Flex System for both Residential Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations INSTALLATION 8 2 4m Min 30 762mm 30 9 1m Max 30 Horizontal Distance Feet Vertical Height feet 2 51mm max ...

Страница 24: ...bead of silicone inside the outer section of the adapter and a bead of Stove Mate on the inner collar Slip the adapter over the existing inner and outer flue collar and fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier Level the fireplace and fasten it to the framing using nails or screws through the nailing strips 4 Assemble the desired combinat...

Страница 25: ...ocation Dropaplumb bob down from the ceiling to the position of the appliance flueexit andmarkthelocation where the flue will penetrate the ceiling Drill a small hole at this point Next drop a plumb bob from the roof to the hole previously drilled in the ceiling and mark the spot where the flue will penetrate the roof 3 A Firestop spacer must be installed in the floor or ceiling of every level To ...

Страница 26: ...s with a soapandwatersolutionorgasleakdetector Do not use open flame for leak testing PILOT ADJUSTMENT Periodically check the pilot flames Correct flame pattern has three strong blue flames 1 flowing around the thermopile 1 around the thermocouple and 1 flowing across the burner it does not have to be touching the burner Note If you have an incorrect flame pattern contact your Regency dealer for f...

Страница 27: ... louvers and bay door if it is installed 3 Open the flush door and remove the door 4 Remove the logs embers rockwool 5 Remove the 2 screws holding the Burner Assembly to the firebox base Push the Burner Assembly to the left and lift out 7 Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap 8 Remove burner orifice with a 1 2 wrench and...

Страница 28: ...nfigurations refer to venting section 15 Using the Allen wrench as shown in Fig 4 rotate the screw clockwise until snug do not overtighten Fig 4 WARNING Do not overtighten the screw Recommended to grip the wrench by the short side 16 Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible Fig 5 17 Re assemble the black protection cap Fig 6 WARNING...

Страница 29: ... embers rockwool 5 Remove the 2 screws holding the Burner Assembly to the firebox base Push the Burner Assembly to the left and lift out 7 Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit and replace pilot cap 8 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold on to the elbow behind the orifice 9 Reinstall new burner orifi...

Страница 30: ...nce and glow on logs 26 Check manual for venting configurations refer to venting section WARNING Do not overtighten the screw Recommended to grip the wrench by the short side 16 Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible Fig 5 17 Re assemble the black protection cap Fig 6 WARNING Also check that the pilot and main burner injectors are...

Страница 31: ...he logs embers rockwool 5 Remove the 2 screws holding the Burner Assembly to the firebox base Push the Burner Assembly to the left and lift out 7 Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit and replace pilot cap 8 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold on to the elbow behind the orifice 9 Reinstall new burne...

Страница 32: ...earance and glow on logs 26 Check manual for venting configurations refer to venting section WARNING Do not overtighten the screw Recommended to grip the wrench by the short side 16 Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible Fig 5 17 Re assemble the black protection cap Fig 6 WARNING Also check that the pilot and main burner injectors...

Страница 33: ...h log Read the instructions below carefully and refer to the diagrams If logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation Log Kit 431 930 contains the following pieces A 250 Rear Log B 254 Middle Cross Log C 253 Front Left Cross Log D 251 Rear Left Log E 252 Front Right Cross Log F Embers G Vermiculite 902 179 H Rockwool 902 153 NOTE If...

Страница 34: ...gently place them on the front of the burner tray in the places shown in the photo below Do not compress the rockwool leave it loose 2 5 2 250 254 2 5 3 251 2 5 3 250 254 2 5 3 254 252 251 250 254 2 5 3 Cutout 9 Test fire to ensure proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any blockage of the burner port...

Страница 35: ...ram 2 Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket Repeat for 2nd spring See diagram 3 To remove the flush door reverse the above steps Optional Flush Trim Attach the round magnets to the back of the top trim piece and to the bottom trim piece then at tach trim to the top and bottom of Flush door FLUSH LOUVERS 1 Install the top louver by s...

Страница 36: ...hermostat may be installed if desired connect the wires as per the wiring diagram Use table below to determine the maximum wire length Note Preferableifthethermostatisinstalled on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA ULC or UL approved may be used CAUTION Do not wire millivolt wall thermostat...

Страница 37: ...ot require a 240VA C supply for operation In case of a power failure the burner switch and the optional remote control thermostat will continue to operate However a 240V A C power supply is needed for the fan blower operation Do not cut the ground terminal off under any circumstances NOTE Even if the fan is not purchased with the unit it is still a good idea to bring power to the receptacle box pr...

Страница 38: ...and to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control sys...

Страница 39: ...curing process The glass should be cleaned or the film will bake on and become very difficult to remove Use a non abrasive cleaner and NEVER clean the glass while it is hot OPERATING INSTRUCTIONS 1 Read and understand these instructions before operating this appliance 2 Check to see that all wiring is correct and enclosed to prevent possible shock 3 Check to ensure there are no gas leaks 4 Make su...

Страница 40: ... check mechanical supports such as Wall Straps or plumbers tape for rigidity GOLD PLATED or BRASS LOUVERS TRIM The 24 carat gold plated or brass finish on the louvers and trim requires little maintenance and need only be cleaned with a damp cloth DO NOT use abrasive materials or chemical cleaners as they may harm the finish and void thewarranty Cleananyfingerprintsoffbefore turning the unit on LOG...

Страница 41: ...ill produce If your glass requires cleaning we recommend using an approved glass cleaner available at all authorized dealers Do not use abrasive materials Do not clean the glass when hot In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only and follow our step by step instructions for replacement Flush Glass Replacement Remove the flush d...

Страница 42: ...couple nut with a 9mm wrench 6 Reconnect the pilot tube nut with a 7 16 wrench 7 Scrapeofftheoldgasketfromthefloorofthe firebox and from the valve tray assembly 8 Install a new gasket and reinstall the valve tray assembly Note Failure to install a new gasket may severely affect the appliance performance 9 Reinstall the 10 hold down screws 10 Hook up the 2 TP and 2 TH wires to the appropriate conne...

Страница 43: ... HeatWave Option 95 946 006 Grill Plate White 96 946 005 Wall Adaptor Plate White 97 910 417 Knob White 98 910 366 Switch Cover Plate White 99 910 412 Fan Speed Controller 100 910 367 Box Plastic Switch Receptacle 102 946 010 Flexible Air Duct 946 038 Insulation 6 dia x 24 104 690 022F Cover Plate 510 994 Dura Vent Adaptor 918 537 Manual 433 968 Conversion Kit NG to LPG 434 967 Conversion Kit NG t...

Страница 44: ...Valve Bracket 59 Firebox Base 60 Valve Tray 66 910 038 Pilot Assy 3 way flame S I T NG 910 039 Pilot Assy 3 way flame S I T LPG 904 568 Orifice 44 NG 904 163 Orifice 54 LPG 936 170 Orifice Gasket 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 79 433 525 Burner Assy NG LPG 82 433 024 Burner Grate Assembly NG LPG 83 Rear Log Support Bracket NG LPG 85 431 930 Log Set 86 430 097 Air Deflector Left 8...

Страница 45: ...0 162 Front Deflector 134 Flush Louver Assy Bottom 433 538 Flush Door Assembly Complete 135 940 088 P Glass Flush 137 904 691 U Clip 139 936 155 Glass Gasket Tadpole 140 948 042 Spring Hinge Black 430 940 Finishing Trim Set Black Option 430 942 Finishing Trim Set Brass Option 157 Finishing Trim Left 159 Finishing Trim Right 158 Finishing Trim Top 431 943 Double Screen Door Complete Option 171 Door...

Страница 46: ... 112 Bay Brick Panel Spacer 117 904 196 Magnet 1 round 118 Louver Hold Down 120 400 189 Glass Retainer 432 956 Bay Door Trim set Gold 432 954 Bay Door Trim set Brass 432 958 Bay Door Trim set Brushed Steel 123 Bay Door Trim each Black 430 932 Bay Louvers set Gold Black 430 934 Bay Louvers set Brass Black 430 936 Bay Louvers set Black 430 937 Bay Louvers set Steel Black 125 Bay Louver Assy Top Bay ...

Страница 47: ...nt or the closest approved service agent is situated more than twenty five 25 kilometres from the installation Air Group Australia are not obliged to arrange warranty repairs and travel and or additional labour charges will apply Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing or trim It does not cover installation and operational related probl...

Страница 48: ...Printed in Canada Copyright 2010 FPI Fireplace Products International Ltd All rights reserved ...

Отзывы: