Figure 51: Location of Electrical Hook-Up.
GAS HOOK-UP:
The L965E/H965E are equipped from the factory with a 1/2” SAE 45º male gas fitting. This
fitting will fit commonly used flexible gas supply lines.
If your local code requires you to use only rigid pipe for gas supply, remove the flare fitting
provided. The gas line is fastened to an MPT flare fitting.
You can then use a common union to provide the gas connection to the appliance.
The dimension shown in Figure 50 are for your convenience if you have to hard pipe directly
to the unit.
NOTES:
This appliance and it’s main gas valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressure in excess of 1/2 psi (3.5
kPa).
Isolate this appliance from the gas supply piping system by closing its the equipment shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to
or less than 1/2 psi (3.5 kPa).
Figure 50: Location of Gas Hook-Up.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding prong from this plug.
An electrical junction box is provided and fastened to the right side of the fireplace. Power needs
to be brought to the electrical junction box. The power for the various control components are
all provided from the fan control module. Install the provided electric outlet and cover and plug
the the fan control module into it. See the Rating Label for the listed electrical requirements.
When installed, the L965E/HZ965E, must be electrically grounded in accordance with local
codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
ELECTRICAL HOOK-UP:
NOTE:
Electrical box is
located inside this
panel-shown outside
to show location.
HZ965/L965 Gas Fireplace |
41
41
|
installation
Содержание Horizon HZ965E
Страница 52: ...SAFETY SCREEN INSTALLATION 52 HZ965 L965 Gas Fireplace 52 installation ...
Страница 66: ...66 HZ965 L965 Gas Fireplace 66 parts list ...
Страница 72: ......
Страница 73: ...HZ965 L965 Gas Fireplace 73 73 notes ...
Страница 74: ...74 HZ965 L965 Gas Fireplace 74 notes ...
Страница 75: ......