PLANNING YOUR INSTALLATION
INTRODUCTION:
This section of the technical manual is for the use of qualified technicians only. Fireplace placement, hearths, facings, mantles, and venting terminations will
be covered, as well as the gas and electric systems. There are several installation safety guidelines that must be adhered to. Please carefully read the safety
precautions at the front of this manual.
Warning:
Clearances must be sufficient to allow access for maintenance and service.
If installing a Power Vent Kit (706-922) or a Heat Distribution Kit (706-921), refer to the instructions included with the kits to aid in your planning.
NON-COMBUSTIBLE MATERIAL ZONE:
This installation guide will show you many options for installing your new L965E/HZ965E Some options include external chases, internal chases, rock facing
and corner installations. No matter what direction your installation takes, this illustration shows an area where no combustible building products may go. This
illustration applies to any and all installations for the L965E /HZ965E and should be used as the first reference before any others. Failure to comply with this
requirement can lead to elevated operating temperatures, degradation of materials or even result in fire. If you are unclear about any details contained here,
consult with your retailer prior to installation.
24"
(610mm)
**52-5/16"
(1329mm)
27-3/4"
(705mm)
11"
(279mm)
Figure 4. Non-Combustible Material Zone.
When Installing a TV above the unit.
ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY.
ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS.
HZ965/L965 Gas Fireplace |
7
7
|
installation
Содержание Horizon HZ965E
Страница 52: ...SAFETY SCREEN INSTALLATION 52 HZ965 L965 Gas Fireplace 52 installation ...
Страница 66: ...66 HZ965 L965 Gas Fireplace 66 parts list ...
Страница 72: ......
Страница 73: ...HZ965 L965 Gas Fireplace 73 73 notes ...
Страница 74: ...74 HZ965 L965 Gas Fireplace 74 notes ...
Страница 75: ......