60
|
Regency Excalibur
®
P90E-11 Direct Vent Gas Stove
maintenance
To Remove the Valve Only
1. Remove pilot nut with 11mm (7/16”) wrench
(Diagram 1). Then remove burner supply tube
from 90 degree brass fitting on valve with 15mm
(5/8”) wrench (Diagram 2). Once the supply
tube has been removed from the 90 degree
brass fitting remove the 90 degree brass fitting
from the valve with a 17 mm (11/16”) wrench
(Diagram 3). Lastly remove supply tube from
valve with 19 mm (3/4”) wrench (Diagram 4).
Note orientation of 90 Degree Brass fitting.
11. Remove the twelve (12) Phillips head screws
from the valve tray, and then remove the valve
tray by lifting up and out. Replace with new valve
assembly and reverse steps. If replacing valve
only, see following steps.
Diagram 7
2. Remove two (2) Phillips head screws on each
side of the valve then remove valve from
mounting bracket.
Diagram 1
Diagram 2
Diagram 3
Diagram 4
Diagram 5
3. Reverse the steps to reinstall new valve.