Regency Excalibur
®
P90E-11 Direct Vent Gas Stove
| 33
installation
Horizontal Venting with Two (2) 90
o
Elbows
Horizontal Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Option V
H + H1
With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
A)
6" Min. 2' Max.
B)
1' Min. 3' Max.
C)
2' Min. 4' Max.
D)
3' Min. 5' Max.
E)
4' Min. 6' Max.
F)
5' Min. 7' Max.
G)
6' Min.
8' Max.
Must Use: 5" x 8" Simpson Direct Vent Piping with FPI Increaser Starter
Collar (Part #946-605)
Must Use: 5" x 8" Simpson Direct Vent Piping with FPI
Increaser Starter Collar (Part #946-605)
One 90
o
elbow = Two 45
o
elbows.
Option V
H V + V1
H + H1
W i t h
t h e s e
options, max. total
pipe length is 30
feet with min. of 12
feet total vertical
and max. 9 feet
total horizontal.
Please note min.
1 foot between
90
o
elbows is
required.
A)
6" Min. 1' Max. 1'6" Min. 2' Max.
B)
1' Min. 2' Max. 3' Min.
3' Max.
C)
2' Min. 2' Max. 5' Min.
4' Max.
D)
3' Min. 2' Max. 7' Min.
5' Max.
E)
4' Min. 3 Max. 9' Min.
6' Max.
F)
5' Min. 4' Max. 10' Min. 7' Max.
G)
6' Min. 5' Max. 11' Min.
8' Max.
H)
7' Min. 6' Max. 12' Min.
9' Max.