16
|
Regency Excalibur
®
P90E-11 Direct Vent Gas Stove
installation
Side Wall Clearance
6-1/2" (165mm)
Horizontal Vent Clearances
Top
2-1/2" (64mm)
Side
1-1/2" (38mm)
Bottom
1-1/2" (38mm)
Vertical Vent Clearances
1-1/4" (32mm)
Alcove Clearances**:
Max. Depth
36" (914mm)
Min. Width
72" (1829mm)
Min. Height
72" (1829mm)
* see mantle clearance instructions
(Refer to the "Combustible Mantels" section).
Clearances
The clearances listed are Minimum distances unless
otherwise stated:
A major cause of chimney related fires is failure
to maintain required clearances (air space)
to combustible materials. It is of the greatest
importance that this fireplace and vent system
be installed only in accordance with these
instructions.
Locating Your
Gas fireplace
1. When selecting a location for your fireplace,
ensure that the clearances outlined on this
page are met.
2. Provide adequate clearances for servicing.
3. The appliance must be installed on a flat, solid,
continuous surface (e.g. wood, metal, concrete).
This may be the floor, or raised up on a platform
to enhance its visual impact. If the appliance is
going to be installed on carpeting, combustible
linoleum tile or other combustible material other
than wood flooring, the appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.
4. The P90E-11 Direct Vent Gas Fireplace
can be installed in a recessed position or
framed out into the room as in A, B, C, D.
See Diagram 1.
Manufactured Mobile Home
Additional Requirements
1. Ensure that structural members are not cut or
weakened during installation.
2. Ensure proper grounding using the #8 ground
lug provided. See the "Wiring Diagram" section.
5. This appliance is Listed for bedroom installations
when used with a Listed Millivolt Thermostat.
Some areas may have further requirements,
check local codes before installation.
6. The P90E-11 Direct Vent Gas Fireplace is
approved for alcove installations, which meet
the clearances listed on this page.
7. We recommend that you plan your installation on
paper using exact measurements for clearances
and floor protection before actually installing this
appliance. Have a qualified inspector, dealer, or
installer review your plans before installation.
Note: For vent terminations see the
"Exterior Vent Termination
Locations" section.
Diagram 1
A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into
Wall/Alcove
D) Corner
HeatWave Duct System
Optional Kit
#946-556
The
HeatWave
Air Duct Kit increases the
effectiveness of your fireplace by dispersing warm
air from the fireplace to remote locations in the same
room or other rooms in your home.
Up to two kits may be installed on the fireplace.
Please Note: Only 1 HeatWave kit may be operated
at one time. This includes the internal blower
option as well.
Optional
Heat Release Kit
#946-570
The Heat Release Kit expels warm air from the
fireplace to the outside of the building, allowing
the fireplace to be operated with less heat entering
the room. The kit may be used on either the left or
right side.
WARNING:
Fire hazard is an extreme risk
if these clearances are not
adhered to.
Clearances for
HeatWave
and
Heat Release Kit
Heat Release Kit
The
HeatWave
Duct Kit and the Heat Release
Kit have different clearance and framing
requirements, check the
HeatWave
and Heat
Release manual for details.
Clearance to Combustibles from:
Back
0"
(0mm)
Side
0"
(0mm)
Floor
0"
(0mm)
(below firebox base)
NOTE: The minimum floor clearance must
be maintained from the top surface of the
carpeting, tile, etc.
See Hearth Requirements in this manual.