94
|
City Series CV72E
maintenance
General Vent Maintenance
Conduct an inspection of the venting system semi-
annually. Recommended areas to inspect as follows:
1. Check the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2. Remove the Cap, and shine a flashlight down
the Vent. Remove any bird nests, or other foreign
material.
3. Check for evidences of excessive condensation,
such as water droplets forming in the inner
liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused
by having excessive lateral runs, too many
elbows, and exterior portions of the system
being exposed to cold weather.
4. Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports
such as Wall Straps, or plumbers' tape for
rigidity.
Log Replacement
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the logs.
(The pilot light generates enough heat to burn
someone.) If for any reason a log should need
replacement, you must use the proper replacement
log. The position of these logs must be as shown
in the diagrams under Log Installation.
Note: Improper positioning of logs may
create carbon build-up and will
severely alter the unit's performance
which is not covered under warranty.
Glass Gasket
If the glass seal on the appliance requires
replacement a graphite seal specifically designed
for this appliance is required. Part # is 666-124 for
the sides with 2 required and part # 666-125 for
the top/bottom with 8 required. These are applied
with self adhesive tape.
There is also gasket installed on each side of
the inner glass to protect against breakage when
installing the glass. Gasket part number is 936-222.
This is sold per foot. 3 feet in total is required to
complete both sides.
Glass
Your Regency
®
fireplace is supplied with high
temperature 5mm-Tempered outer glass & 5mm-
Ceramic inner glass. If your glass requires cleaning,
we recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all
product warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the
glass front or with a cracked or broken
glass front.
* Wear gloves and safety glasses when removing
damaged or broken glass.
* Replacement of the glass panels should be
done by a licensed or qualified service per
son.
Glass Replacement
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass is shipped
already installed into the door frame. Reinstall as per
Glass Installation in the "Glass Installation" section.
REPLACEMENT GLASS:
CV72E
Outer Safety Glass- Tempered (Part#940-490/P)
Inner Glass - Ceramic (Part#940-450 /P)
Maintenance Instructions
1. Always turn off the gas valve before cleaning.
For relighting, refer to lighting instructions. Keep
the burner and control compartment clean by
brushing and vacuuming at least once a year.
When cleaning the logs, use a soft clean paint
brush as the logs are fragile and easily damaged.
2. Clean appliance and door with a damp cloth
(never when unit is hot). Never use an abrasive
cleaner. The glass should be cleaned with a gas
fireplace glass cleaner.
The glass should be
cleaned when it starts looking cloudy.
3. The fireplace is finished in a heat resistant paint
and should only be refinished with heat resistant
paint. Regency
®
uses StoveBright Paint - Metallic
Black #6309.
4. Make a periodic check of burner for proper
position and condition. Visually check the flame
of the burner periodically, making sure the flames
are steady; not lifting or floating. If there is a
problem, call a qualified service person.
5. The appliance and venting system must be
inspected before use, and at least annually, by
a qualified field service person, to ensure that
the flow of combustion and ventilation air is not
obstructed.
Note: Never operate the appliance without
the glass properly secured in place.
6. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to
replace nay part of the control system and any
gas control which has been under water.
7. In the event this appliance has been serviced
check that the vent-air system has been properly
resealed & reinstalled in accordance with the
manufacturer's instructions.
8. Verify operation after servicing.
N
ote: If you have an incorrect flame pattern,
contact your Regency
®
dealer for further
instructions.
Incorrect flame pattern will have small, probably
yellow flames, not coming into proper contact
with the rear burner or flame sensor.
Flame Pattern
Periodically check the pilot and main burner
flames. Correct pilot flame pattern has two
strong blue flames: 1 flowing around the flame
sensor and 1 flowing across the burner (it does
not have to be touching the burner).
Correct main burner flame pattern
Содержание City CV72E-LP11
Страница 104: ...104 City Series CV72E ...
Страница 105: ...City Series CV72E 105 notes ...
Страница 106: ...106 City Series CV72E notes ...
Страница 107: ...City Series CV72E 107 ...