City Series CV72E

  |    

43

installation

Typical Installations

Flush TV with Hearth

Maximum TV Recess

Note: The TV mounting bracket can not be secured directly to the appliance. It must be secured to framing. The TV depicted in the picture may need to be 
higher depending on the style of TV mounting bracket used. The mounting bracket shown is a simple single strip TV secured to framing.

CB72EPV Typical Installs

MAXIMUM TV RECESS

FLUSH TV WITH HEARTH

5/8”

 maximum TV recess

using 1/2” drywall

Flush wall TV install using 1/2" (13 mm) drywall.

Max 36”

Hearth

Max 5 

1/8

Mantle

Max 4 

1/2

TV recess with drywall

up against unit

288in

2

 min 

Chase Vent opening

Shown with Regency

Chase Vent 666-532

Max 2”

To Top of Enclosure

Header Stud

29 

1/4”

 

min

25.75”

 min

61 

3/4”

 min

Screws must not 

penetrate unit more 

than 1/2” .

Adhere to “No Screw”

zones painted on unit.

Glue can be used

as an alternative.

Содержание City CV72E-LP11

Страница 1: ...e gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Warning Fire or explosion Hazard failure to follow safety warnings exactly could result in serious injury death or property damage 919 931j FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta B...

Страница 2: ...ted gas appliance where the temperature of the glass viewing area outside surface exceeds the limits specified in Clause 5 14 4 the following graphic danger and statements shall be shown on a Class IIIA 2 Permanent Label 4 34 6 Instruction Plate Each appliance shall bear a Class IIIB marking with letters on a contrasting background located adjacent to the controlling device or in an equally conspi...

Страница 3: ...l Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This Regency mobile manufactured home listed appliance comes factory equipped with four 1 4 diameter holes located near each corner of the base Fasten the fireplace in place using screw inserted through the holes This appliance comes equipped w...

Страница 4: ...nations Rigid Pipe 5 x 8 51 Horizontal Terminations Rigid Pipe 5 x 8 52 Horizontal Venting with Two 2 90o Elbows 52 Horizontal Venting with Three 3 90o Elbows 52 Venting Introduction 53 Venting Arrangement for Horizontal Terminations 53 Installer s Information Owner s information Horizontal Termination 5 x 8 Venting Flex Vent Systems 54 Horizontal Termination 5 x 8 Venting Rigid Vent Systems 55 Ve...

Страница 5: ... CFR Part 3280 Manufactured Home Construction and Safety Standard Si ces normes ne sont pas applicables veuillez vous référer à la normeANSI NCSBCSA225 1 NFPA501A Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée É U seulement ou mobile installée à demeure si les règlements locaux le permettent Voi...

Страница 6: ... 20 03 3m mm m 4 4 6 6 1 1 1 1 6 6 8 8 m m m m 2 20 0 8 8 5 51 17 7m mm m Dimensions Note Height Dimension is taken with leveling legs fully inserted and may vary depending on the height of the leveling legs when unscrewed or extended Dimensions will appear as inches metric mm throughout this manual The inches are rounded to the nearest 1 16 when converted when greater accuracy is required use the...

Страница 7: ...tom of Unit Gas Connection Side of Unit removable knockouts 17 5 5 5 17 36 1 4 36 1 4 3 7 8 20 1 3 12 1 2 7 Front of Unit Back of Unit Gas Valve 14 1 2 Opening at unit base 11 5 Front of unit Back of unit 3 7 8 tooltip Front of Unit Back of Unit 12 7 8 5 2 1 2 Right Side Left Side ...

Страница 8: ...s CV72E installation Electrical Connection Bottom of Unit Electrical Connection Side of Unit Front of Unit Back of Unit 20 1 3 12 1 2 7 77 7 16 Receptacle Electrical opening 8 tip 2 3 4 Front of unit Back of unit 4 ...

Страница 9: ...o top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply with venting diagrams Is venting installed and secured and are clearances for the vent pipe and termination cap maintained If applicable was a 1 4 rise maintained for every foot of horizontal run Was the termination ...

Страница 10: ...er on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if installed and flame modulation checked Customer Tutorial and Presentation YES NO Is the customer confident operating the new gas appliance and aware of all the features on the remote Confirm that the rating and lighting pl...

Страница 11: ... OF THE ROOM AND AWAY FROM HOT SURFACES Important Message SAVE THESE INSTRUCTIONS City Line Direct Vent Fireplaces must be installed in accordance with these instructions Carefully read all the instructions in this manual first Consult the authority having jurisdiction to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensure this fir...

Страница 12: ...ator or valve Unit Body Firebox Differenttypesandthicknessesofsteelwillexpand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process During the first few fires a white film may developontheglassfrontaspartofthecuring process Theglassshouldbecleanedafterthe unit has cooled down or the film will bake on and become very difficult to ...

Страница 13: ...he battery holder switch to the ON position if equipped Note The first try for ignition will last approximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out Th...

Страница 14: ...oper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas scrupuleusement les instructions de la présente notice risque de déclencher un incendie ou...

Страница 15: ...ure 1 Proflame Transmitter Figure 2 Transmitter LCD Display TECHNICAL DATA REMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the b...

Страница 16: ...tep until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The thermosta...

Страница 17: ...peed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmable light control To activate this...

Страница 18: ...s easily changed from an intermittent pilot ignition system IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensa tion on start up Provides owners with flexibility to...

Страница 19: ...rs of the glass If you don t have these place a soft cloth or piece of cardboard under the glass barrier to protect the corners during removal 4 Using the vacuum clamps lift the barrier straight up pull it toward you then gently lower it straight down see below Open Vacuum clamps Closed Vacuum clamps Corner protector Corner protector Lift Pull forward Lower down Angle out 5 Angle the bottom edge t...

Страница 20: ...ecommend handling the glass with supplied vacuum clamps When removing glass prepare a soft scratch resistant surface to place the 70 3 8 x15 1 4 glass Never clean or remove hot glass Note The suction cups may leave a round film on the glass when used Ensure that the glass is cleaned using a fireplace glass cleaner after each removal and prior to operating the appliance Note glass panels must be in...

Страница 21: ... on supports Lower clamps x9 in open position Push down on levers to lower glass panel Gasket pad NOTE The firebox glass may remain propped on the glass supports to clean the interior surface Use care when cleaning do not apply excessive force or pressure 9 To remove the firebox glass panel from the unit tilt the glass forward gently onto the glass supports grip both suction clamps and lift the gl...

Страница 22: ...rt to the glass barrier if desired install the stoppers prior to installation of the barrier glass 1 If already installed remove the side panel by pulling off and lifting out 2 Slidethestopperbracketinbetweenthefrontpanelandtheunitwallasshown 3 Reinstall the side panel 5 Proceed to installation of the barrier glass Barrier stoppers installed 4 Repeat steps 1 3 on the opposite side ...

Страница 23: ...complete procedure NOTE Do not handle bulb with bare hands Use packaging or a tissue to hold new bulb when replacing Regency Part 911 208 Oven Lamp Assembly G9 120V 25W Regency Part 911 072 Replacement Bulb G9 120 Volt 25 watt Outer light covers shown from back of unit back made transparent Light are located behind the front face of the unit Inner light covers shown from back of unit back made tra...

Страница 24: ...lost within the home 4 AA bat teries may be used in the battery box to operate the appliance See wall mount ON OFF switch and battery holder installation for location of 4 AA batteries as the battery box should be located in a convenient location on the wall The lights will not operate when 120 volt power is lost The remote control may still be used as normal when power is lost Maintenance Instruc...

Страница 25: ...rectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspe...

Страница 26: ...tion Codes 2 See general construction and assembly instructions The appliance and vent should be enclosed 3 This appliance must be connected to the specifiedventandterminationcaptotheoutside of the building envelope Never vent to another room or inside a building Make sure that the vent is fitted as per Venting instructions 4 Inspecttheventingsystemannuallyforblockage and any signs of deterioratio...

Страница 27: ...ramed out into the room as in A B C and D See Diagram 1 A Flat on Wall CV72E Diagram 1 B Flat on Wall Corner CV72E C Recessed into Wall Alcove CV72E D Corner CV72E 4 For bedroom installations check with local codes before installation This appliance is offered with a remote control 5 The CV72E Direct Vent Gas Fireplace is ap provedforalcoveinstallations see Clearances section for details 6 We reco...

Страница 28: ...ce to the rear wall if needed Studs must be in this location if choosing to screw this into studs Leveling legs Leveling Legs There are four levelling legs two on each side that can be adjusted with the supplied tool found in the manual package if required tooltip Remove the screws securing the unit to the pallet Due to the size and weight 529 pounds shipping weight of the CV72E lifting and moving...

Страница 29: ...nce the finished material is installed these access panels are no longer accessible tooltip tooltip Gas connection Aeration adjustment Electrical 1 Identify access panel to be removed remove corresponding outer trim panel by lifting up and off centre panel shown below 2 From inside the unit push in tab to release the access panel at the top 3 Push the access towards the inside of the unit lift up ...

Страница 30: ...Minimum opening height must be 2 1 2 64mm measured from top of enclosure to the ceiling and must be in open in front and both sides to meet the minimum 288 square inches free open air requirement Ventilation Opening Locations The following are examples of how the ventilation openings may be placed above the fireplace If using the optional heat wave kit this does not reduce the size of the ventilat...

Страница 31: ...prevent heat from escaping anywhere above through the enclosure other than the required grill ventilation opening Internal chase When installing as an internal chase framing installation regardless of where appliance is placed within the home requires the use of either drywall or other means such as plywood on the rear wall of the chase to eliminate heat escaping into the rear wall cavity If the c...

Страница 32: ...ireplace Opening C Sidewall on one side 8 203mm Side of Fireplace Opening D Mantel Depth max E Alcove Width 88 2135mm Sidewall to Sidewall Minimum F Alcove Depth 36 914mm Front to Unit Maximum G Ceiling in front of fireplace 61 3 4 1568mm Top of Fireplace Opening H Convection Air Outlet 288 square inches J Convection Air Outlet Opening Offset 0 2 0 51mm Max offset from top of chase enclosure K Cha...

Страница 33: ...on the right Mantel Leg Clearances Combustible mantel leg clearances as per diagram 2 12 6 4 8 10 0 14 9 15 1 16 10 20 26 Top of Fireplace Opening 12 305mm 1 2 Drywall wood wood panel etc 5 1 8 To Bottom of Fireplace Opening 12 Allowable mantel MANTEL LEG leg projection 9 10 5 7 12 Allowable mantel MANTEL LEG leg projection 9 10 5 7 ...

Страница 34: ... can be achieved Note Thisappliancemustbe installed on a solid surface such as a plywood floor which must be the full width and depth of the appliance With the lift handles adding approximately 4 inches to the overall width of the appliance In cases where the appliance would need to be raised off the ground in order to slide it into the framed opening it is suggested that either the framing width ...

Страница 35: ...N Max 2 Ceiling Ceiling Top of chase enclosure Max 2 Stud Stud Stud Stud 72 Chase Vent 72 Chase Vent Opening for vent 5 5 5 Min 74 25 Framed Opening must be between 5 and 5 5 tall and at least 74 25 wide to accomodate the Chase vent The top of the chase vent opening must be 2 or less from the top of the chase enclosure ...

Страница 36: ...36 City Series CV72E installation 919 830b 01 23 18 2 CITY SERIES Drywall HeaderStud Finish edges of drywall with trim or corner bead Edge finish must not decrease opening area below 306in2 4 25 x72 ...

Страница 37: ...Clearances Page Screw Chase vent to Framing Use at least 4 sets of screws to keep the vent flat against frami Frame wall with finishing material If necessary mark where the chase vent is located before fixing drwall in place Cut hole in finishing material around inside of chase vent Finish edges around opening Drywall ...

Страница 38: ...nd right base panels using 2 screws on each side Re move drywall finishing edge from right and left side of window open ing using supplied right angle screwdriver 4 Move unit into framed opening at desired height and level unit on all sides Connect gas and electrical see manual EXTENDED VIEW PANEL INSTALLATION Mounting holes Enclosure width CV40E 46 3 4 CV72E 78 Attach base panels Install second s...

Страница 39: ...structions in unit manual 11 Install glass panels onto base panels glass panels are secured in place with magnets 12 Glass panels should overlap with outer side liner panel as shown below NOTE Remove side liner panel and extended view panel to access firebox Finish to the dashed line only Base panel with finishing Finish wall Install inner panels Install glass panels Correctly installed glass pane...

Страница 40: ...lower access cover panel Longer screws may penetrate gas line or damage valve or electrical components Note It is acceptable to use a high temperature silicone sealant to adhere drywall to lower access cover panel The appliance is designed to be used with a minimum 1 2 in wall sheathing materials such as drywall plywood wood composites or non combustible materials Thicker materials may be used Ref...

Страница 41: ...tuds etc installed tightly with no gaps As this appliance has been designed with all hot air escaping through the chase enclosure ventilation grill openings only if hot air is trapped as a result of the hot air escaping through joints crevasses open studs or other openings within the enclosure above this will change the clearances within the enclosure causing the enclosure to overheat It is vital ...

Страница 42: ... to No Screw zones painted on unit Glue can be used as an alternative 2 288in min Chase Vent opening using a reveal to vent the chase 61 3 4 min CV72Typical Installs FLUSH INSTALL RECESSED INSTALL 1 2 drywall directly onto unit 288in2 min Chase Vent opening Shown with Regency Chase Vent 666 991 Max 2 To Top of Enclosure 1 8 Max 5 Mantle 3 1 2 framing in front of unit plus nishing material Max 36 H...

Страница 43: ...a simple single strip TV secured to framing CB72EPV Typical Installs MAXIMUM TV RECESS FLUSH TV WITH HEARTH 4 5 8 maximum TV recess using 1 2 drywall Flush wall TV install using 1 2 13 mm drywall Max 36 Hearth Max 5 1 8 Mantle Max 4 1 2 TV recess with drywall up against unit 288in2 min Chase Vent opening Shown with Regency Chase Vent 666 532 Max 2 To Top of Enclosure Header Stud 29 1 4 min 25 75 m...

Страница 44: ...surface Recess Install Example Flush Install Example Finish up to trim on all 4 sides Loosen screws using supplied Offset Screwdriver and remove bottom and side trim pieces Front edge of side liner panels must not be covered by finishing material or removal of the Firebox Glass will not be possible Bottom edge should be flush with top surface of Inner Liner Panel ...

Страница 45: ...ove meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public propert...

Страница 46: ...58DVA CS 5DT CSS 5DRS TM 5SS DV CSS05 Wall Support Band 58DVA WS 5DT WS B 5DWS TM 5WS VDV WS05 Offset Support 58DVA ES 5DT OS N A TM 5OS N A Wall Thimble Black 58DVA WT 5DT WT 5DWT N A VDV WPT05 Wall Thimble Support Ceiling Support 58DVA DC N A N A N A N A Firestop Spacer 58DVA FS 5DT FS 5DFS TM 5LS VDV FS05 Trim Plate Black 58DAV WFS 5DT TP 5DCP TM 5TP VDV WTC05 5 X 8 RIGID PIPE CROSS REFERENCE C...

Страница 47: ...ith all rigid piping 946 506 P Vent Guard Optional 946 606 Starter collar reducer 5 x 8 to 4 x 6 5 8 B36XTE B36XTCE ONLY 946 625 Vinyl Siding Standoff AstroCap XL Note When using Metal Fab Sure Seal Rigid Piping please note that the Adaptor 5DDA must be used in conjunction with FPI Rigid Pipe Adaptor 770 994 Not available applicable for the following units B41XTE B41XTCE CB60E CV60E CV72E HZ54E U1...

Страница 48: ...5 Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the Battery Holder switch in the OFF position to allow correct lineup for slider switch 8 Make sure the Battery Holder and cover plate words ON and UP are on the same side 9 Align the slider with the switch on the Battery Holder and couple the switch into the slider 1...

Страница 49: ...ams refer to the following instructions 1 Remove the safety barrier glass and firebox glass see instructions in this manual 2 Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown 3 Once the vent restrictor plate is in the required position secure with screws Vent Restrictor Position t t o o o o l l t t i i p p Front of Unit Back of Unit Vent Restricto...

Страница 50: ...Flex Vent 5 x 8 These venting systems in combination with the CV72E Direct Vent Gas Fireplace has been tested and listed as a direct vent heater system by Intertek The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in Exterior Vent Termination Locations section Regency Direct Vent Flex System Termination Kits include all the parts needed to ...

Страница 51: ...tion withDuraventDirect Vent SelkirkDirect Temp Ameri Vent Direct Venting ICC Excel Direct Olympia Ventis DV and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does notaffecttheIntertekWHIlistingofcomponents WARNING Do not combine venting components from different venting systems However use of the the AstroCapTM and FPI Riser is acceptable w...

Страница 52: ...otherwise rigid venting must be used H H1 V Horizontal Venting with Two 2 90o Elbows One 90o elbow Two 45o elbows Option V H H1 With these options maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 1 Min 2 Max B 2 Min 4 Max C 3 Min 5 Max D 4 Min 6 Max E 5 Min 7 Max F 6 Min 8 Max ...

Страница 53: ... diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adapter Part 770 994 when using Rigid Pipe Venting Systems Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever...

Страница 54: ...he other thimble half to the inside wall The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls 5 Slip the assembled liner and termination as sembly through the thimble making sure the termination cap faces up there are markings on the cap that show which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the...

Страница 55: ... and frame the square hole in the exterior wall where the vent will be terminated See diagram 54 for center line requirements If the wall being penetrated is constructed of non combustible material i e masonry block or concrete an 8 203mm diameter hole is acceptable Notes a The horizontal run of vent must be level or have a 1 4 inch rise for every 1 foot of run towards the termination Never allow ...

Страница 56: ... 0 76 over 10 12 to 11 12 3 25 0 99 over 11 12 to 12 12 4 1 22 over 12 12 to 14 12 5 1 52 over 14 12 to 16 12 6 1 83 over 16 12 to 18 12 7 2 13 over 18 12 to 20 12 7 5 2 29 over 20 12 to 21 12 8 2 44 Pipe Length Vertical Terminal Storm Collar Flashing Ceiling Firestop Rigid Pipe Adapter This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct V...

Страница 57: ...henever passing through a wall Must use optional rigid pipe adaptor Part 770 994 when using rigid pipe vent systems Vertical Venting with Three 3 90o Elbows One 90o elbow Two 45o elbows V H1 H V1 Option V H H1 V V1 With these options max totalpipelength is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required A 1 Min 2 Max ...

Страница 58: ... feet Firestops are required at each floor level and whenever passing through a wall Must use optional rigid pipe adaptor Part 770 994 when using rigid pipe vent systems Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting of Set 0 through to Set 3 if required Maximum 37 ft 11 2m Minimum 8 6 2 6m Min 56 1 4 1429mm Minimum length of...

Страница 59: ...offsetlimitations 2 Set the gas appliance in its desired location Drop a plumb bob down from the ceiling to the position of the appliance flue exit and mark the location where the vent will penetrate the ceiling Drill a small hole at his point Next drop a plumb bob from the roof to the hole previously drilled in the ceiling and mark thespotwherethevent will penetrate the roof Determine if ceiling ...

Страница 60: ...adaptor using Mill Pac over the adaptor Slide the inner pipe over the flex to rigid adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex 3 Cut a hole in the roof centered on the small hole placed in the roof in the previous steps The hole should be a minimum of 11 279 mm The hole may be round and or square 4 Slip the flashing under the shingles and line up flashing so it is cent...

Страница 61: ...y See Simpson Duravent components list in the instruction manual for part numbers Flex Pipe Ceiling Firestop Roof Support Brace Flashing Storm Collar Termination Cap Ceiling Firestop Enclosure Flex Pipe Ceiling Firestop Roof Support Flashing Elbow Support Termination Cap Storm Collar Ceiling Firestop Support to prevent sagging Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof s...

Страница 62: ... and slip the 5 127 mm inner flex pipe from the Vertical termination kit over the flex adapter ensuring that the inner flex pipe overlaps the collar by at least 1 4 35 mm Fasten with 3 screws 4 Apply a bead of Mill Pac around the perimeter of the 8 203 mm outer collar of the flue adapter and slip it over the 8 203 mm outer flex pipe from the vertical termination kit ensuring that the outer flex pi...

Страница 63: ... in conjunction with the 946 755 Vertical flex kit and 946 756 kit Vertical flex extension kit Horizontal power vent kit Firestop spacer to prevent debris from falling into the ceiling firestop Aceiling firestop firestop spacer must be installed when passing through each floor orceiling level Toinstall theceilingfirestop firestop spacer in a flatceiling or floor joist cut a 279 mm square hole Fram...

Страница 64: ...ews 1 Remove the deflector from the top of the unit by removing 4 screws 2 Remove the knockout from the top of the unit and recycle 3 Fold up 3 tabs up as shown 4 Connect pipe adaptor with 3 screws use the lower holes on the adaptor 5 Connect the flex pipe to the adaptor with 3 screws 6 Fold the deflector removed from Step 1 fold the 4 tabs to 90 and secure the tabs to the unit with 4 screws ...

Страница 65: ... For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement NOTE A shutoff dante valve should be sup plied in or near the ...

Страница 66: ...ds the back of the unit and then out 4 Bring the wiring from inside the wall through the opening created when the plate was removed in the previous step 5 Wire the electrical box NOTE The receptacle and receptacle cover may be located in the manual pack and may need to be installed 6 Feed any excess wiring into the wall and reinstall the plate onto the wall of the unit 7 Reinstall electrical box a...

Страница 67: ...attery Holder WIre Harness 21 911 187 Battery Holder 22 911 190 Flame Modulator NG Item Part Description 22 911 191 Flame Modulator LP 23 N A Battery Connection 24 N A Adjustment Screw 25 911 242 Outlet Pressure Ports 26 911 173 Valve Wire Harness 27 911 188 Valve NG 911 189 Valve LP 28 911 193 Connector w Jumper CAUTION Label all wires prior to disconnection when servicing controls Wiring errors ...

Страница 68: ...e glass with supplied vacuum clamps When removing glass prepare a soft scratch resistant surface to place the glass Never clean or remove hot glass Note The suction cups may leave a round film on the glass when used Ensure that the glass is cleaned using a fireplace glass cleaner prior to operating the appliance To watch the glass installation video click here http youtu be DsPbbiLIbdU Note glass ...

Страница 69: ...9 in open position Push down on levers to lower glass panel Gasket pad NOTE The firebox glass may remain propped on the glass supports to clean the interior surface Use care when cleaning do not apply excessive force or pressure 9 To remove the firebox glass panel from the unit tilt the glass forward gently onto the glass supports grip both suction clamps and lift the glass up and out of the unit ...

Страница 70: ...to the glass barrier if desired install the stoppers prior to installation of the barrier glass 1 If already installed remove the side panel by pulling off and lifting out 2 Slidethestopperbracketinbetweenthefrontpanelandtheunitwallasshown 3 Reinstall the side panel 5 Proceed to installation of the barrier glass Barrier stoppers installed 4 Repeat steps 1 3 on the opposite side ...

Страница 71: ...peration of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION Cable from motor Conversion Kit 666 977 includes 1 911 011 Stepper Motor LP for 885 SIT 1 905 014 Orifice 47 1 910 037 Pilot Orifice 30 1 918 590 Decal Conversion to LP 1 908 528 Label Propa...

Страница 72: ...th the LPG pilot orifice and the pilot cap provided in the kit Installer Notice These instructions must be left with the appliance Pilot retainer clip 14 Remove burner orifice with a 3 8 wrench Use another wrench to hold on to the elbow behind the orifice Discard orifice Reinstall new burner orifice LPG stamped 47 and tighten tooltip Burner Orifice Location 13 Loosen 8 screws in locations shown be...

Страница 73: ...ass assembly in place 7 Replace bulb and reverse steps to complete procedure NOTE Do not handle bulb with bare hands Use packaging or a tissue to hold new bulb when replacing Regency Part 911 208 Oven Lamp Assembly G9 120V 25W Regency Part 911 072 Replacement Bulb G9 120 Volt 25 watt Outer light covers shown from back of unit back made transparent Light are located behind the front face of the uni...

Страница 74: ...uter panels and 10 inner panels Turn off gas and power to unit and allow to cool to room temperature Remove the safety glass and firebox glass see manual for instructions Install bracket into slot in panel tooltip tooltip 2 On back of firebox wall install 6 screws loosely in locations shown below Install 3 back panels hang panels on installed screws through keyhole opening 1 Install 3 front outer ...

Страница 75: ...e panel 4 Slide the panel and bracket into the unit until it contacts the back panel 5 Secure panel in position with one screw 6 Repeat steps 2 4 to install opposite panel 1 Install 5 inner base panels as shown tooltip The CV72E may be equipped with optional enamel inner panels CV72E 5 outer panels and 10 inner panels Turn off power and gas to unit and allow to cool to room temperature Remove the ...

Страница 76: ...6 Install two back panel brackets in between the back wall and the burner tray Line up the center of each bracket with the base panels installed in the previous step as shown below 7 Carefully manoeuvre the back glass panels 6 7 8 to the back wall of the firebox Start with back panel 6 place twopanel brackets on each panel and manoeuvreintoposition slidingthebottomintothecornerandbackbrackets 8 Se...

Страница 77: ...ase panels 11 12 and 13 in the front of the unit 15 Slide the glass barrier stopper bracket in between the front panel and the unit wall as shown 16 Install side outer panel 14 by manoeuvering the panel between the wall and the barrier stopper bracket as shown below Repeat on other side to install panel 15 The panels are held in place by magnets 17 Install barrier glass see unit manual for instruc...

Страница 78: ...he pilot area Media must be installed on and around burner only in amounts noted below CV72E Approved Media Where Used Quantity Fireglass starfire copper or black On burner 2lbs Glowing embers sea wool supplied with unit On burner 1 bag 3 4 Black Coal Around burner 2 boxes 7lbs Crushed Iceburg chips Around burner 2 boxes 7lbs Firebeads Around burner 7lbs Stone River Pebbles Around burner 1 box Spa...

Страница 79: ...6 Right end log Log Brackets 3 Lava rock purchased separately from log set 2 lb Black Fireglass purchased separately from log set Glowing wool supplied with unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 Shut off gas and electrical supply allow unit to cool to room temperature 2 Remove barrier glass if already installed and firebox glass see manual 3 Carefully re...

Страница 80: ...tals as shown 9 Install Log 4 in front of the burner on the panel Position the left end of Log 4 2 1 2 to the right of the left end of the burner as shown below 10 The left end of Log 4 should also sit 2 from the edge of the panel as shown below 4 2 11 Place Log 5 on the center panel in front of the burner Position the left end of the log 17 from the left edge of the burner as shown below 12 Place...

Страница 81: ...the pin locator on Log 9 with the pin on Log 1 and rest the other end of Log 9 on the rest on Log 4 as shown below Log 7 end lined up with 4th vertical bar Black Coal around logs on panels Log 9 Log 8 8 2 1 2 Landing for Log 11 Note Log 7 and Log 14 appear very similar Log 7 has a landing for Log 11 Log14doesnot PleasecarefullyidentifyLog7beforeinstalling Keep front secondary air inlets clear Do n...

Страница 82: ...part of the Y of Log 13 on the rest in Log 4 Rest the opposite end of Log 13 on the back edge of the burner as shown 22 Install Logs 15 and 16 place each log on the glass at each end of the burner as shown below Log 12 1 3 5 2 4 13 15 16 11 12 14 6 9 10 7 8 Final Install Log 13 Log 14 Logs 15 16 21 Install Log 14 place one end of Log 14 on the rest on Log 8 and the opposite end on the back edge of...

Страница 83: ...log far right log 15 Left end log 16 Right end log Log Brackets 3 Lava rock purchased separately from log set 2 lb Black Fireglass purchased separately from log set Glowing wool supplied with unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 Shut off gas and electrical supply allow unit to cool to room temperature 2 Remove barrier glass if already installed and fire...

Страница 84: ...ystals as shown 9 Install Log 4 in front of the burner on the panel Position the left end of Log 4 2 1 2 to the right of the left end of the burner as shown below 10 The left end of Log 4 should also sit 2 from the edge of the front panel 11 Place Log 5 on the center panel in front of the burner Position the left end of the log 17 from the left edge of the burner as shown below 12 Place Log 6 on t...

Страница 85: ...alled on the panels as shown below 16 Install Log 9 line up the pin locator on Log 9 with the pin on Log 1 and rest the other end of Log 9 on the rest on Log 4 as shown below Log 7 end lined up with 4th vertical bar Black Coal around logs on panels Log 9 Log 8 placement 8 2 1 2 Keep front secondary air inlets clear Do not completely cover side secondary air inlets Correct Black Coal placement Drif...

Страница 86: ...part of the Y of Log 13 on the rest in Log 4 Rest the opposite end of Log 13 on the back edge of the burner as shown 21 Install Log 14 place one end of Log 14 on the rest on Log 8 and the opposite end on the back edge of the burner as shown below 22 Install Logs 15 and 16 place each log on the glass at each end of the burner as shown below Log 12 1 3 5 2 4 13 15 16 11 12 14 6 9 10 7 8 Final Instal...

Страница 87: ...left log 14 Right cross log far right log 15 Left end log 16 Right end log Log Brackets 3 Lava rock purchased separately from log set 2 lb Black Fireglass purchased separately from log set Glowing wool supplied with unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 Shut off gas and electrical supply allow unit to cool to room temperature 2 Remove barrier glass if al...

Страница 88: ... right of the left end of the burner as shown below 10 The left end of Log 4 should also sit 2 from the edge of the panel as shown below 11 Place Log 5 on the center panel in front of the burner Position the left end of the log 17 from the left edge of the burner as shown below 12 Place Log 6 on the diagonal line up the centre of Log 6 with the center vertical line at the front of the burner 13 In...

Страница 89: ...he pin on Log 1 and rest the other end of Log 9 on the rest on Log 4 as shown below Black Coal around logs on panels Log 9 Log 8 Keep front secondary air inlets clear Do not completely cover side secondary air inlets Correct Black Coal placement 18 Install Log 11 line up the pin locator on Log 11 with the pin on Log 1 and rest the other end of Log 11 on the rest on Log 7 as shown below Log 11 17 I...

Страница 90: ... the Y of Log 13 on the rest in Log 4 Rest the opposite end of Log 13 on the back edge of the burner as shown 22 Install Logs 15 and 16 place each log on the glass at each end of the burner as shown below Log 12 1 3 5 2 4 13 15 16 11 12 14 6 9 10 7 8 Final Install Log 13 Log 14 Logs 15 16 21 Install Log 14 place one end of Log 14 on the rest on Log 8 and the opposite end on the back edge of the bu...

Страница 91: ...glass then close the clamps while maintaining pressure on the glass 4 Slide the corner protectors onto the bottom corners of the glass 5 Holding the glass barrier in front of the unit slide it up behind the top lip of the unit Lift the barrier up as far as it goes then hook the barrier onto the unit Push forward Lower onto hooks Lift up Slide behind top lip Open Vacuum clamps Closed Vacuum clamps ...

Страница 92: ...t If glass isn t hanging straight use a phillips screwdriver to adjust the angle Clockwise angles barrier out toward you Counter clockwise angles barrier in towards the unit Slide the screwdriver straight up at the two indicator slots Glass Barrier Adjustment ...

Страница 93: ...to remove Remove t to oo ol lt ti ip p Aeration access door 3 Attach the handle to the aeration lever through the access opening handle will slide into position on the lever 4 Adjust aeration accordingly Pushing lever in closes the air shutter Pulling the lever outward opens the air shutter Minimum Air Shutter Opening NG 3 16 NG with Logs 3 16 NG with Stones 3 16 LP 3 8 LP with Logs 3 8 LP with St...

Страница 94: ... without the glass front or with a cracked or broken glass front Wear gloves and safety glasses when removing damaged or broken glass Replacement of the glass panels should be done by a licensed or qualified service per son Glass Replacement In the event that you break your glass by impact purchase your replacement from an authorized Regencydealeronly Replacementglassisshipped alreadyinstalledinto...

Страница 95: ...ont and 2 at rear slide burner to the left away from the orifice and lift out 9 Remove 8 screws in locations shown below 10 Lift valve tray out partially and disconnect flexible gas connection on the valve inlet side remove valve tray replace with new valve tray 11 Reverse Steps 7 1 to complete Burner screw locations Slide burner to the left and lift out t to oo ol lt ti ip p t to oo ol lt ti ip p...

Страница 96: ... be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise etc Should any of these...

Страница 97: ...City Series CV72E 97 parts list 30 31 31 2 11 3 1 11 16 21 20 19 25 29 27 24 27 24 18 22 23 4 5 6 7 8 9 10 32 14 13 15 15 32 CV72E Main Assembly ...

Страница 98: ...Box Proflame II N S 911 173 Wire Harness IFC No CPI Switch 584 924 N S 911 266 P IFC Board SIT Proflm II 7day PV 5 Sec FFRT 0 584 625 N S 911 175 Remote Control GTMFL SIT 0 584 042 N S 910 369 Receptacle Box Low Volt SC100A N S 910 576 Cover Wall Mount White 0 584 803 N S 910 428 Receptacle Duplex White N S 910 429 Receptacle Duplex Metal N S 910 430 Receptacle Cover Duplex Metal N S 904 687 Conne...

Страница 99: ...lack Sold only as complete sets N S 656 955 Extended View Kit Black Glass N S 666 991 Chase Vent Front Black N S 666 995 Adaptor Heat Wave N S 946 556 Heatwave Kit N S 946 672 Stones River Pebbles N S 946 674 Stones Ceramic Spa 70 stones N S 946 675 Fireglass Black Reflective 1 4in 1Lb Pkg N S 946 676 Fireglass Copper 1 4 in 1Lb Pkg N S 946 677 Fireglass Starfire 1 4 in 1Lb Pkg N S 946 775 Firegla...

Страница 100: ... Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled compon...

Страница 101: ...ation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance are n...

Страница 102: ...ld consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief descript...

Страница 103: ...r us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANAD...

Страница 104: ...104 City Series CV72E ...

Страница 105: ...City Series CV72E 105 notes ...

Страница 106: ...106 City Series CV72E notes ...

Страница 107: ...City Series CV72E 107 ...

Страница 108: ...______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial _____________________________________________________________ Printed in Canada Regency and City Series are trademarks of FPI Fireplace Products International Ltd Copyright 2021 FPI Fireplace Products International L...

Отзывы: