background image

Installer

: Please complete the details on the back cover and leave this 

manual with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

 Certified to/Certifié pour: CSA 2.17-2017
                                             ANSI Z21.88-2017
                                             CSA 2.33-2017

City Series® 

CB72E POWER VENT 

Owners & 

Installation Manual

STYLE

 

                     

     MODEL 

   

Three sided                            CB72EPV-NG / CB72EPV-LP
Corner Conversion                   671-927 / 671-928

Tested by: 

www.regency-fire.com

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     WARNING
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

919-888c

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

08.14.19

Содержание City CB72EPV-LP

Страница 1: ...his or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by...

Страница 2: ...atulations You are the owner of a state of the art Gas Fireplace by REGENCY The City Series are hand crafted appliances and have been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The CB72EPV City Series have been approved by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and...

Страница 3: ...al Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This Regency mobile manufactured home listed appliance comes factory equipped with four 1 4 diameter holes located near each corner of the base Fasten the fireplace in place using screw inserted through the holes This appliance comes equipped ...

Страница 4: ... the appliance s connected to the venting system are located and other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the venting system Turn on any exhaust fans such as range hoods and bathroom exhausts so they are operating at maximum speed Do not operate a summer exhaust fan 6 Follow the lighting instructions Place the appliance being...

Страница 5: ...eplacement 102 Glass Gasket 102 Glass 102 Glass Replacement 102 Valve Replacement 103 Power Vent Maintenance 104 CB72EPV Main Assembly 106 Power Vent 109 Warranty 110 Copy of Safety Decal 6 Important Message 9 Before You Start 9 First Fire 10 Normal Operating Sounds Of Gas Appliances 10 Lighting Procedure 11 Shutdown Procedure 11 Copy of the Lighting Plate Instructions 12 Proflame II Remote Contro...

Страница 6: ...as Code ANSI Z223 1 or Natural Gas and Propane Installation Code CSA B149 1 This appliance must be installed in accordance with the Standard CAN CSAZ240 MH Mobile Housing in Canada or with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States or when such a standard is not applicable ANSI NCSBCSA225 1 NFPA501A Manufactured Home Installations Standard Th...

Страница 7: ...eling legs fully inserted and may vary depending on the height of the leveling legs when unscrewed or extended Dimensions will appear as inches metric mm throughout this manual The inches are rounded to the nearest 1 16 when converted when greater accuracy is required use the metric dimensions Note These units are non load bearing ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRA...

Страница 8: ... leveling legs when unscrewed or extended Dimensions will appear as inches metric mm throughout this manual The inches are rounded to the nearest 1 16 when converted when greater accuracy is required use the metric dimensions Note These units are non load bearing ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENT...

Страница 9: ...VIDUALSOUT OF THE ROOM AND AWAY FROM HOT SURFACES Important Message SAVE THESE INSTRUCTIONS City Line Direct Vent Fireplaces must be installed in accordance with these instructions Carefully read all the instructions in this manual first Consult the authority having jurisdiction to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensur...

Страница 10: ... gas regulator or valve Unit Body Firebox Differenttypesandthicknessesofsteelwillexpand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process During the first few fires a white film may developontheglassfrontaspartofthecuring process Theglassshouldbecleanedafterthe unit has cooled down or the film will bake on and become very dif...

Страница 11: ...t try for ignition will last approximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off by pr...

Страница 12: ...fe Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas scrupuleusement les instructions de la présente notice risque de déclencher un ince...

Страница 13: ...ransmitter LCD Display TECHNICAL DATA REMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batteries In case of remote control ma...

Страница 14: ...step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The thermost...

Страница 15: ...speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmable light control To activate thi...

Страница 16: ...is easily changed from an intermittent pilot ignition system IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensa tion on start up Provides owners with flexibility t...

Страница 17: ... Slide the corner protectors onto the bottom corners of the glass If you don t have these place a soft cloth or piece of cardboard under the glass barrier to protect the corners during removal 4 Using the vacuum clamps lift the barrier straight up pull it toward you then gently lower it straight down see below Open Vacuum clamps Closed Vacuum clamps Corner protector Corner protector Lift Pull forw...

Страница 18: ...tment If glass isn t hanging straight use a phillips screwdriver to adjust the angle Clockwise angles barrier out toward you Counter clockwise angles barrier in towards the unit Slide the screwdriver straight up at the two indicator slots Glass Barrier Adjustment ...

Страница 19: ...nty We recommend handling the glass with supplied vacuum clamps When removing glass prepare a soft scratch resistant surface to place the 70 3 8 x 15 1 4 glass Never clean or remove hot glass Note The suction cups may leave a round film on the glass when used Ensure that the glass is cleaned using a fireplace glass cleaner after each removal and prior to operating the appliance Note glass panels m...

Страница 20: ...g on supports Lower clamps x9 in open position Push down on levers to lower glass panel Gasket pad NOTE The firebox glass may remain propped on the glass supports to clean the interior surface Use care when cleaning do not apply excessive force or pressure 9 To remove the firebox glass panel from the unit tilt the glass forward gently onto the glass supports grip both suction clamps and lift the g...

Страница 21: ...lass Note if gasket pad won t open check that all clamps are turned a full 90 3 Open 2x top clamps by turning 90 4 Gently move bottom of side glass panel into the support channel as shown in diagram below 5 Tilt top of glass side panel outward to create clearance 6 Remove panel 7 Repeat steps to remove side glass panel on the opposite side 8 Reverse steps to re install side glass panels ...

Страница 22: ...tion of the barrier glass 4 Repeat steps 1 6 to install outer panels on opposite side 5 Install barrier glass as per instructions in this manual 3 Install glass stopper if desired by sliding stopper assembly between unitandpanel thestopperassemblywillattachtotheunitviaamagnet adjust position of glass stopper is required 2 Slide backwall outer panel behind glass stopper bracket if installed 1 Insta...

Страница 23: ... individual inner light cover and remove 4 Replace bulb and reverse steps to complete procedure NOTE Do not handle bulb with bare hands Use packaging or a tissue to hold new bulb when replacing Regency Part 911 208 Oven Lamp Assembly G9 120V 25W Regency Part 911 072 Replacement Bulb G9 120 Volt 25 watt Light are located behind the front face of the unit Inner light covers shown from back of unit b...

Страница 24: ...dintothedoorframe Reinstallasper GlassInstallationinthe GlassInstallation section REPLACEMENT GLASS CB72EPV Outer Safety Glass Front Tempered Part 940 500 P Outer Safety Glass Right Side Tempered Part 940 502 P Outer Safety Glass Left Side Tempered Part 940 503 P Inner Glass Front Ceramic Part 940 499 P Inner Glass Side Ceramic Part 940 498 P Maintenance Instructions 1 Always turn off the gas valv...

Страница 25: ...irectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon insp...

Страница 26: ...nected to the specifiedventandterminationcaptotheoutside of the building envelope Never vent to another room or inside a building Make sure that the vent is fitted as per Venting instructions 4 Inspecttheventingsystemannuallyforblockage and any signs of deterioration 5 Venting terminals shall not be recessed into a wall or siding 6 Any safety glass removed for servicing must be replaced prior to o...

Страница 27: ...ionsreferto ExteriorVent Termination Locations section E Diagram 1 D 3 sided CB72EPV corner install E 3 sided CB72EPV Locating Your Gas Fireplace Corner Install 1 When selecting a location for your fireplace ensure that the clearances are met 2 The appliance must be installed on a flat solid continuous surface For example a wood metal or concrete floor or in a raised on the wall ap plication The a...

Страница 28: ...ation if choosing to screw this into studs tooltip Leveling legs Leveling Legs There are four levelling legs two on each side that can be adjusted with the supplied tool found in the manual package if required tooltip Remove the screws securing the unit to the pallet Due to the size and weight 581 pounds shipping weight of the CB72EPV lifting and moving the unit will require 4 people Place a lengt...

Страница 29: ... right Note Once the finished material is installed these access panels are no longer accessible tooltip tooltip Gas connection Aeration adjustment Electrical 1 Identify access panel to be removed remove corresponding outer trim panel by lifting up and off centre panel shown below 2 From inside the unit push in tab to release the access panel at the top 3 Push the access towards the inside of the ...

Страница 30: ... be installed only in accordance with these instructions The HeatWave Duct Kit has differ ent clearance and framing require ments checktheHeatWavemanual for details E F B Alcove Clearance single sided Dimension Measured From A1 Mantel Height min Top of Fireplace Opening A From Floor min 0 Bottom of Fireplace Opening B Sidewall on one side Min 8 203mm Side of Fireplace Opening C Enclosure Width min...

Страница 31: ... front sides or top Full framing with low vents in front or sides Full framing with vents in front or sides K C I A1 A D L J H B L I C D A1 A J G G H H H B I C G A A1 G D J L H H B I A D C J G G L H H A1 Bottom of fireplace opening Bottom of fireplace opening Bottom of fireplace opening Bottom of fireplace opening ...

Страница 32: ...tion Clearances will be the same for the right hand side Clearance single sided Dimension Measured From A Mantel Height min Top of Fireplace Opening B Opening Height 15 1 16 383mm Bottom Top of Fireplace Opening C From Floor Min 0 Bottom of Fireplace Opening D Sidewall on one side Min 26 660mm Side of Fireplace Opening E Mantel Depth Max Front of Fireplace Opening F Alcove Depth Min 36 914mm Front...

Страница 33: ...s from top of front facing are shown in the diagram on the right Mantel Leg Clearances Combustible mantel leg clearances as per diagram 2 12 6 4 8 10 0 14 9 15 1 16 10 20 26 Top of Fireplace Opening 12 305mm 1 2 Drywall wood wood panel etc 5 1 8 To Bottom of Fireplace Opening 12 MANTEL LEG 8 ...

Страница 34: ...ined minimum of 288 square inches of open area is required for the con vection air outlet to cool the enclosure Ensureclearances for Convection Air Outlets are met See clearances CB72EPV in this manual as there are dif ferent methods as to how this can be achieved Note Thisappliancemustbe installed on a solid surface such as a plywood floor which must be the full width and depth of the appliance E...

Страница 35: ... manual as there are different meth ods as to how this can be achieved Note This appliance must be in stalled on a level and solid surface such as a plywood floor which must be the full width and depth of the appliance Framing Dimensions Description Corner Kit A Framing Height 51 1295mm B Framing Width 84 2134mm C Framing Depth 20 5 8 524mm D Unit Base to Top Enclosure Min 87 2210mm G Vent Centerl...

Страница 36: ...his manual as there are different meth ods as to how this can be achieved NOTE Unit cannot be load bearing All finishing materials must be supported by the framing Note This appliance must be in stalled on a level and solid surface such as a plywood floor which must be the full width and depth of the appliance Maximum material di mensions 2 x 4 for header studs installed on edge and flat Framing D...

Страница 37: ...y Steps 920 068 02 20 19 CB72 CORNER CONVERSION ASSEMBLY STEPS 1 Decide on Left or Right install Install outer panel of corner conversion before placing unit in framing 2 Install trim guide for left or right install to the outer side panel L R LEFT RIGHT 1 CB72 CORNER ...

Страница 38: ...n the two self tapping screws to the top of the outer side panel Unit can be placed in framing at this point 5 Slide outer side panel down onto screws that remain from removable trim Tighten screws with offset screwdriver 7 See inner panel install section Once firebox panels are installed then install corner conversion liner panel inside of side barrier glass Note Gasket side of panel sits against...

Страница 39: ...ng trim guides 9 Install outer liner panels and then recycle unused side and back panel 10 Slide corner piece in right up to firebox glass 11 Slide corner piece up to outer side panel until contact with magnet is made 12 Once corner conversion is installed continue regular install of barrier glass Discard unused side glass barrier 3 CB72 CORNER ...

Страница 40: ...t B with 2x Part H with 8 screws installed from back of frame 2 Install the frame assembled in Step 1 onto the back of the unit as shown with 2 screws on each side 3 Place unit against wall in desired location Level the unit by adjusting 4 leveling bolts on unit 4 Install venting before proceeding further with framing kit construction Refer to manual for venting instructions w w w w Framing Kit wi...

Страница 41: ...he 2 center supports Part I to upper and lower Part B of the back frame with 2 screws each as shown 7 Attach the 4 x end pieces Part J to the upper and lower Part B of the back frame with two screws each 8 Attach 2 x Part G to the previously installed Part J parts with 2 screws at each end 9 Attach end cross braces Parts E F with 2 screws at each end as shown below 10 Install Part A x2 to Part G o...

Страница 42: ...orizontal mid braces Part K with one screw on each end installed from the top 12 Install 4 front supports Part C to upper and lower Part A with 2 screws on each end 13 Install 2 top and 2 inner diagonal supports Part D with 2 screws at each end Part K Part D Part C Part ID overview ...

Страница 43: ... Gas Valve Back of Unit Front of Unit 3 1 4 4 1 1 2 2 1 2 11 1 2 5 18 1 2 5 18 1 2 5 11 1 2 2 1 2 1 1 2 15 1 2 39 14 1 2 19 1 2 11 1 4 6 3 4 Opening at unit base Gas Valve Back of Unit Front of Unit 3 1 4 5 12 1 4 4 1 1 2 2 1 2 11 1 2 5 18 1 2 5 18 1 2 5 11 1 2 2 1 2 1 1 2 15 1 2 39 3 1 4 5 12 1 4 4 1 1 2 2 1 2 11 1 2 5 18 1 2 5 18 1 2 15 1 2 39 4 12 1 4 5 3 1 4 1 19 1 2 11 1 4 6 3 4 Gas Valve Bac...

Страница 44: ... 11 1 2 5 18 1 2 5 18 1 2 5 11 1 2 2 1 2 1 1 2 15 1 2 39 14 1 2 19 1 2 11 1 4 6 3 4 Opening at unit base Gas Valve Back of Unit Front of Unit 3 1 4 5 12 1 4 4 1 1 2 2 1 2 11 1 2 5 18 1 2 5 18 1 2 5 11 1 2 2 1 2 1 1 2 15 1 2 39 4 12 1 4 5 3 1 4 14 1 2 19 1 2 11 1 4 6 3 4 Opening at unit base Gas Valve Back of Unit Front of Unit ...

Страница 45: ... 2 Ceiling Ceiling Top of chase enclosure Max 2 Stud Stud Stud Stud 72 Chase Vent 72 Chase Vent Opening for vent 5 5 5 Min 74 25 Framed Opening must be between 5 and 5 5 tall and at least 74 25 wide to accomodate the Chase vent The top of the chase vent opening must be 2 or less from the top of the chase enclosure ...

Страница 46: ...46 City Series CB72EPV installation 919 830b 01 23 18 2 CITY SERIES Drywall HeaderStud Finish edges of drywall with trim or corner bead Edge finish must not decrease opening area below 306in2 4 25 x72 ...

Страница 47: ... Clearances Page Screw Chase vent to Framing Use at least 4 sets of screws to keep the vent flat against frami Frame wall with finishing material If necessary mark where the chase vent is located before fixing drwall in place Cut hole in finishing material around inside of chase vent Finish edges around opening Drywall ...

Страница 48: ...crews more than 1 2 inch in length on the lower access cover panel Longer screws may penetrate gas line or damage valve or electrical components Note It is acceptable to use a high temperature silicone sealant to adhere drywall to lower access cover panel The appliance is designed to be used with a minimum 1 2 in wall sheathing materials such as drywall plywood wood composites or non combustible m...

Страница 49: ...the facing wall MUST be sealed mudded and taped to finish Note that in all applications while there is a zero clearance to combustibles to the unit all clearances to combustibles from the venting inside the chase still applies Please see venting clearances in the specific product manual 4 Combustible material drywall wood wood panels etc may be brought up to the appliance top bottom and sides 5 En...

Страница 50: ...Chase Vent opening Shown with Regency Chase Vent 666 532 Max 2 To Top of Enclosure Max 5 1 8 Mantle 3 1 2 framing in front of unit plus finishing material Max 36 Hearth Header Stud 29 1 4 min 25 75 min 61 3 4 min Screws must not penetrate unit more than 1 2 Adhere to No Screw zones painted on unit Glue can be used as an alternative 288in2 min Chase Vent opening using a reveal to vent the chase ...

Страница 51: ...cket shown is a simple single strip TV secured to framing CB72EPV Typical Installs MAXIMUM TV RECESS FLUSH TV WITH HEARTH 4 5 8 maximum TV recess using 1 2 drywall As per CB40 Dealer display Max 36 Hearth Max 5 1 8 Mantle Max 4 1 2 TV recess with drywall up against unit 288in2 min Chase Vent opening Shown with Regency Chase Vent 666 532 Max 2 To Top of Enclosure Header Stud 29 1 4 min 25 75 min 61...

Страница 52: ... top surface Recess Install Example Flush Install Example Finish up to trim on all 4 sides Loosen screws using supplied Offset Screwdriver and remove bottom and side trim pieces Front edge of side liner panels must not be covered by finishing material or removal of the Firebox Glass will not be possible Bottom edge should be flush with top surface of Inner Liner Panel ...

Страница 53: ...ace objects in front of the air outlet s Regency Chase Vent Dimensions 4 x72 288in2 Custom chase vent Example dimensions 2 5 x116 290in2 Reveal at the chase top Example dimensions 2 x160 320in2 Venting into an adjacent room Minimum 288in2 Note An adjacent room cannot be a garage closed in carport Note The enclosure opening cannot be any lower than 0 2 from the top of the enclosure for all installa...

Страница 54: ...e installed prior to finishing 3 Connect the 6 pin connector to the back of the Battery Holder 4 Install the Battery Holder in the Low Voltage Junction box 5 Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the Battery Holder switch in the OFF position to allow correct lineup for slider switch 8 Make sure the Battery ...

Страница 55: ...ion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public property 84 2 1m N Clearance under veranda porch deck or balcony 12 30cm 1 In accordance with current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance w...

Страница 56: ... 994 AND 946 606 PIPE REDUCER TO 4 X 6 5 8 Note Rigid pipe is approved for up to 72 feet FLEX VENT MUST USE REDUCER 946 758 TO 4 X 6 5 8 Note Flex pipe is approved for up to 40 feet using 2 X 946 756 20 foot flex kits 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 8 Horizontal Feet 4 0 6 10 12 16 18 14 20 22 24 3 Ft max 32 34 28 26 30 36 38 42 44 40 46 48 50 54 56 52 58 60 Vertical Feet...

Страница 57: ... N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB N A Extension Pipe 16 Galvanized 46DVA 16A N A N A ...

Страница 58: ...emperatures and may present a possible fire hazard Offset Pipe Selection Use this table to determine offset pipe lengths Pipe Length L 4 x 6 5 8 Venting For specific instructions on venting components visit the manufacturers website listed below Run X Rise Y 0 0mm 4 7 8 124mm 13 7 8 340mm Simpson Direct Vent Pro www duravent com 6 152mm 8 203mm 16 1 2 419mm Selkirk Direct Temp www selkirkcorp com ...

Страница 59: ... 1 Wallthickness ismeasuredfromthebackstandoffs to theinsidemounting surfaceofterminationcap Createalevelsurfacetomounttheventterminal TheTerminalmustnotberecessedintosiding Measurethewallthickness Flat Wall Installation Wall Thickness inches Vent Length Required inches 4 5 1 2 6 7 8 1 2 9 10 11 1 2 12 9 14 1 2 11 14 5 8 Adj Pipe 15 23 1 2 17 24 Adj Pipe Adj Pipe Length Rigid Pipe Adapter o 90 Elb...

Страница 60: ...est results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Horizontalrunsofventmustbesupportedevery 3 feet 0 9meter Wall straps are available for this purpose 6 Mark the wall for a square hole see chart to lef...

Страница 61: ...t with Vent Terminal 1 770 994 Rigid Pipe adaptor sold separately 1 946 606 Reducer required sold separately 1 Power Vent Fan included w Power Vent kit 1 Power Vent Frame included w Power Vent kit 1 911 250 P 45 5 wire BX cable or sold separately 1 911 251 P 90 5 wire BX cable sold separately amount required for install 4 x 6 5 8 Rigid Pipe sold separately 1 946 535 Power Vent Kit sold separately ...

Страница 62: ...ater Fasten the cap to the outer wall with the 4 supplied screws 5 Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fire place You may wish to cut the liner shorter to make it more workable Do not bend liner more than 90 The liners must slip over the collars a minimum of 1 3 8 6 Apply Mill Pac over the fireplace inner flue collar and slip the inner flex li...

Страница 63: ...its Part 946 756 If longer runs are required rigid pipe must be used 5 Reducer 946 758 must be used in all applications when using flex venting Horizontal Terminations Flex Vent 4 x 6 5 8 These venting systems in combination with the CB72EPV Direct Vent Gas Fireplace has been tested and listed as a direct vent heater system by Intertek The location of the termination cap must conform to the requir...

Страница 64: ...175 mm outer flex pipe from the vertical termination kit ensuring that the outer flex pipe overlaps the collar by at least 1 3 8 35mm Fasten with the 3 screws 5 Repeat steps to secure the other end of the flex adapter using the flex kit 6 See Vertical Vent installation instructions or horizontal power vent instal lation instructions for installation of the complete vent system Note If an offset is...

Страница 65: ... 4 x 6 5 8 Ceiling Firestop Firestop Spacer 919 698 06 12 18 60 1 4 Ceiling firestop Diagram 1 Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop A ceiling firestop firestop spacer must be installed when passing through each floor or ceiling level To install the ceiling fi...

Страница 66: ...wer Vent components installation instructions 120 Volt power supply is required to operate this system 946 535 Power Vent Kit with Vent Terminal 1 946 758 Reducer required sold separately 2 Max 946 756 20 Flex Kit sold separately 1 Power Vent Fan included w Power Vent kit 1 Power Vent Frame included w Power Vent kit 1 911 250 P 45 5 wire BX cable or sold separately 1 911 251 P 90 5 wire BX cable s...

Страница 67: ...thickness of faceplate NOTE Exterior finishes such as thin vinyl siding may warp if closer than 2 from them vent For interior installations on vinyl siding a 2 frame buffer zone must be created between the finishing and the vent 8 Install Power Vent unit into framed opening using 4 screws as shown below 9 Seal the edges of the Power Vent unit to the framing there are two seams 2 Run the venting an...

Страница 68: ...d Wire Ground Blue Wire Grommet in bracket Grommet in bracket Red to Red Black to Black Black to White 17 Connect remaining wires from Powervent motor to BX cable Black to Black and Black to White Cap paired wires with supplied marrette NOTE After exposure to heat White wire will appearYellow Blue wires will appear Green 18 Reinstall rain guard and tighten screws 19 Reinstall front faceplate with ...

Страница 69: ...fthejunctionboxasthiswillbeattached later Only the 4 colored wires go into the junction box 4 Join Powervent and BX cable wires together by firstly splicing 1 off wires join black to black white to white Diagram 6 5 Join the Pressure switch and BX cable wires by splicing 1 off wires join red to red and blue to blue Diagram 7 6 After the Power and Pressure switches have been connected place wired c...

Страница 70: ...sting ground located above IFC board Diagram 9 9 Once wiring is complete plug unit into power located on the right side of unit next to junction box Diagram 10 reinstall gasket pad removed in Step 7 reinstall access panel removed in Step 2 and exterior panels removed in Step 1 Diagram 9 Diagram 10 Ground from BX ...

Страница 71: ...ectrical box plate towards the back of the unit and then out 4 Bring the wiring from inside the wall through the opening created when the plate was removed in the previous step 5 Wire the electrical box NOTE The receptacle and receptacle cover may be located in the manual pack and may need to be installed 6 Feed any excess wiring into the wall and reinstall the plate onto the wall of the unit 7 Re...

Страница 72: ...controls Wiring errors can cause improper and dangerous operation 120 Volt AC power is required A receptacle box receptacleandcoverareprovidedandlocatedonthe righthandsideoftheunit undertheouterbasepanel Electrical power must be brought to the appliance by a licensed electrician Do not cut the ground terminal off under any circumstances BLACK BATTERY HOLDER BATTERY CONNECTION VARIABLE LIGHTS WHITE...

Страница 73: ...For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement NOTE A shutoff dante valve should be sup plied in or near the u...

Страница 74: ...rews 1 Remove the deflector from the top of the unit by removing 4 screws 2 Remove the knockout from the top of the unit and recycle 3 Fold up 3 tabs up as shown 4 Connect pipe adaptor with 3 screws use the lower holes on the adaptor 5 Connect the flex pipe to the adaptor with 3 screws 6 Fold the deflector removed from Step 1 fold the 4 tabs to 90 and secure the tabs to the unit with 4 screws ...

Страница 75: ... We recommend handling the glass with supplied vacuum clamps When removing glass prepare a soft scratch resistant surface to place the 70 3 8 x 15 1 4 glass Never clean or remove hot glass Note The suction cups may leave a round film on the glass when used Ensure that the glass is cleaned using a fireplace glass cleaner after each removal and prior to operating the appliance Note glass panels must...

Страница 76: ... supports Lower clamps x9 in open position Push down on levers to lower glass panel Gasket pad NOTE The firebox glass may remain propped on the glass supports to clean the interior surface Use care when cleaning do not apply excessive force or pressure 9 To remove the firebox glass panel from the unit tilt the glass forward gently onto the glass supports grip both suction clamps and lift the glass...

Страница 77: ...ssure on the glass 4 Slide the corner protectors onto the bottom corners of the glass 5 Holding the glass barrier in front of the unit slide it up behind the top lip of the unit Lift the barrier up as far as it goes then hook the barrier onto the unit Push forward Lower onto hooks Lift up Slide behind top lip Open Vacuum clamps Closed Vacuum clamps Corner protector Corner protector 6 Visually insp...

Страница 78: ...nt If glass isn t hanging straight use a phillips screwdriver to adjust the angle Clockwise angles barrier out toward you Counter clockwise angles barrier in towards the unit Slide the screwdriver straight up at the two indicator slots Glass Barrier Adjustment ...

Страница 79: ... to the glass barrier if desired install the stoppers prior to installation of the barrier glass 1 If already installed remove the side panel by pulling off and lifting out 2 Slidethestopperbracketinbetweenthefrontpanelandtheunitwallasshown 3 Reinstall the side panel 5 Proceed to installation of the barrier glass Barrier stoppers installed 4 Repeat steps 1 3 on the opposite side ...

Страница 80: ...operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION Cable from motor Conversion Kit 666 977 includes 1 911 011 Stepper Motor LP for 885 SIT 1 905 014 Orifice 47 1 910 037 Pilot Orifice 30 1 918 590 Decal Conversion to LP 1 908 528 Label Prop...

Страница 81: ...ith the LPG pilot orifice and the pilot cap provided in the kit Installer Notice These instructions must be left with the appliance Pilot retainer clip 14 Remove burner orifice with a 3 8 wrench Use another wrench to hold on to the elbow behind the orifice Discard orifice Reinstall new burner orifice LPG stamped 47 and tighten tooltip Burner Orifice Location 13 Loosen 8 screws in locations shown b...

Страница 82: ...ividual inner light cover and remove 4 Replace bulb and reverse steps to complete procedure NOTE Do not handle bulb with bare hands Use packaging or a tissue to hold new bulb when replacing Regency Part 911 208 Oven Lamp Assembly G9 120V 25W Regency Part 911 072 Replacement Bulb G9 120 Volt 25 watt Light are located behind the front face of the unit Inner light covers shown from back of unit back ...

Страница 83: ...fety glass and firebox glass see manual for instructions 2 On back of firebox wall install 6 screws loosely in locations shown below Install 3 back panels hang panels on installed screws through keyhole opening 3 Reinstall firebox glass see instructions in manual 3 Slide backwall outer panel behind glass stopper bracket if installed 1 Install outer side panel as shown below 2 Install glass stopper...

Страница 84: ...nel set installed complete by installing barrier glass 9 Reverse all steps to remove panels 5 Install middle outer panel 6 Install glass stopper if desired by sliding stopper assembly between unit and panel the stopper assembly will attach to the unit via a magnet adjust position of glass stopper is required 2 CITY SERIES ...

Страница 85: ...s before applying heat to the unit Failure to do this will result in burn stain on panels which you will be unable to remove Not protected by product warranty The CB72E has optional enamel inner panels that may be installed CV72E 7 outer panels and 8 inner panels Turn off power and gas to unit and allow to cool to room temperature Remove the safety glass and firebox glass see manual for instructio...

Страница 86: ...all middle outer panel 6 Install glass stopper if desired by sliding stopper assembly between unit and panel the stopper assembly will attach to the unit via a magnet adjust position of glass stopper is required 7 Repeat steps 1 6 to install outer panels on opposite side 8 With panel set installed complete by installing barrier glass 9 Reverse all steps to remove panels 2 CITY SERIES ...

Страница 87: ...four back panel brackets in between the back wall and the burner tray Line up the center of the middle brackets with the base panels installed in the previous step as shown below 7 Carefully manoeuvre the back glass panels 9 10 11 to the back wall of the firebox Start with back panel 9 place two panel brackets on each panel and manoeuvre into position sliding the bottom into the corner and back br...

Страница 88: ...t ifinstalled 14 Install outer corner panel 14 as shown below 15 Install middle outer panel 15 17 Repeatsteps1 6toinstallouterpanels 16 17 18 ontheoppositeside 18 Aftercompletepanelsetinstalled completebyinstallingbarrierglass 19 Reverse all steps to remove panels 16 Install glass stopper if desired by sliding stopper assembly between unit and panel the stopper assembly will attach to the unit via...

Страница 89: ...anic Stones on burner or in the pilot area Media must be installed on and around burner only in amounts noted below CB72EPV Approved Media Where Used Quantity Fireglass starfire copper or black On burner 2lbs Glowing embers sea wool supplied with unit On burner 1 bag 3 4 Black Coal Around burner 2 boxes 7lbs Crushed Iceburg chips Around burner 2 boxes 7lbs Firebeads Around burner 7lbs Stone River ...

Страница 90: ...16 Right end log Log Brackets 3 Lava rock purchased separately from log set 2 lb Black Fireglass purchased separately from log set Glowing wool supplied with unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 Shut off gas and electrical supply allow unit to cool to room temperature 2 Remove barrier glass if already installed and firebox glass see manual 3 Carefully r...

Страница 91: ...stals as shown 9 Install Log 4 in front of the burner on the panel Position the left end of Log 4 2 1 2 to the right of the left end of the burner as shown below 10 The left end of Log 4 should also sit 2 from the edge of the panel as shown below 4 2 11 Place Log 5 on the center panel in front of the burner Position the left end of the log 17 from the left edge of the burner as shown below 12 Plac...

Страница 92: ... the pin locator on Log 9 with the pin on Log 1 and rest the other end of Log 9 on the rest on Log 4 as shown below Log 7 end lined up with 4th vertical bar Black Coal around logs on panels Log 9 Log 8 8 2 1 2 Landing for Log 11 Note Log 7 and Log 14 appear very similar Log 7 has a landing for Log 11 Log14doesnot PleasecarefullyidentifyLog7beforeinstalling Keep front secondary air inlets clear Do ...

Страница 93: ... part of the Y of Log 13 on the rest in Log 4 Rest the opposite end of Log 13 on the back edge of the burner as shown 22 Install Logs 15 and 16 place each log on the glass at each end of the burner as shown below Log 12 1 3 5 2 4 13 15 16 11 12 14 6 9 10 7 8 Final Install Log 13 Log 14 Logs 15 16 21 Install Log 14 place one end of Log 14 on the rest on Log 8 and the opposite end on the back edge o...

Страница 94: ... log far right log 15 Left end log 16 Right end log Log Brackets 3 Lava rock purchased separately from log set 2 lb Black Fireglass purchased separately from log set Glowing wool supplied with unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 Shut off gas and electrical supply allow unit to cool to room temperature 2 Remove barrier glass if already installed and fir...

Страница 95: ...rystals as shown 9 Install Log 4 in front of the burner on the panel Position the left end of Log 4 2 1 2 to the right of the left end of the burner as shown below 10 The left end of Log 4 should also sit 2 from the edge of the front panel 11 Place Log 5 on the center panel in front of the burner Position the left end of the log 17 from the left edge of the burner as shown below 12 Place Log 6 on ...

Страница 96: ...talled on the panels as shown below 16 Install Log 9 line up the pin locator on Log 9 with the pin on Log 1 and rest the other end of Log 9 on the rest on Log 4 as shown below Log 7 end lined up with 4th vertical bar Black Coal around logs on panels Log 9 Log 8 placement 8 2 1 2 Keep front secondary air inlets clear Do not completely cover side secondary air inlets Correct Black Coal placement Dri...

Страница 97: ... part of the Y of Log 13 on the rest in Log 4 Rest the opposite end of Log 13 on the back edge of the burner as shown 21 Install Log 14 place one end of Log 14 on the rest on Log 8 and the opposite end on the back edge of the burner as shown below 22 Install Logs 15 and 16 place each log on the glass at each end of the burner as shown below Log 12 1 3 5 2 4 13 15 16 11 12 14 6 9 10 7 8 Final Insta...

Страница 98: ...r left log 14 Right cross log far right log 15 Left end log 16 Right end log Log Brackets 3 Lava rock purchased separately from log set 2 lb Black Fireglass purchased separately from log set Glowing wool supplied with unit 3 4 Crushed black glass or iceburg chips purchased separately from log set 1 Shut off gas and electrical supply allow unit to cool to room temperature 2 Remove barrier glass if ...

Страница 99: ...e right of the left end of the burner as shown below 10 The left end of Log 4 should also sit 2 from the edge of the panel as shown below 11 Place Log 5 on the center panel in front of the burner Position the left end of the log 17 from the left edge of the burner as shown below 12 Place Log 6 on the diagonal line up the centre of Log 6 with the center vertical line at the front of the burner 13 I...

Страница 100: ...the pin on Log 1 and rest the other end of Log 9 on the rest on Log 4 as shown below Black Coal around logs on panels Log 9 Log 8 Keep front secondary air inlets clear Do not completely cover side secondary air inlets Correct Black Coal placement 18 Install Log 11 line up the pin locator on Log 11 with the pin on Log 1 and rest the other end of Log 11 on the rest on Log 7 as shown below Log 11 17 ...

Страница 101: ...of the Y of Log 13 on the rest in Log 4 Rest the opposite end of Log 13 on the back edge of the burner as shown 22 Install Logs 15 and 16 place each log on the glass at each end of the burner as shown below Log 12 1 3 5 2 4 13 15 16 11 12 14 6 9 10 7 8 Final Install Log 13 Log 14 Logs 15 16 21 Install Log 14 place one end of Log 14 on the rest on Log 8 and the opposite end on the back edge of the ...

Страница 102: ...ass then close the clamps while maintaining pressure on the glass 4 Slide the corner protectors onto the bottom corners of the glass 5 Holding the glass barrier in front of the unit slide it up behind the top lip of the unit Lift the barrier up as far as it goes then hook the barrier onto the unit Push forward Lower onto hooks Lift up Slide behind top lip Open Vacuum clamps Closed Vacuum clamps Co...

Страница 103: ...nt If glass isn t hanging straight use a phillips screwdriver to adjust the angle Clockwise angles barrier out toward you Counter clockwise angles barrier in towards the unit Slide the screwdriver straight up at the two indicator slots Glass Barrier Adjustment ...

Страница 104: ...and out to remove Remove tooltip Aeration access door 3 Attach the handle to the aeration lever through the access opening handle will slide into position on the lever 4 Adjust aeration accordingly Pushing lever in closes the air shutter Pulling the lever outward opens the air shutter Minimum Air Shutter Opening NG 3 16 NG with Logs 3 16 NG with Stones 3 16 LP 3 8 LP with Logs 3 8 LP with Stones 3...

Страница 105: ...s and safety glasses when removing damaged or broken glass Replacement of the glass panels should be done by a licensed or qualified service per son Glass Replacement In the event that you break your glass by impact purchase your replacement from an authorized Regencydealeronly Replacementglassisshipped alreadyinstalledintothedoorframe Reinstallasper GlassInstallationinthe GlassInstallation sectio...

Страница 106: ...n below 2 at front and 2 at rear slide burner to the left away from the orifice and lift out 9 Remove 8 screws in locations shown below 10 Lift valve tray out partially and disconnect flexible gas connection on the valve inlet side remove valve tray replace with new valve tray 11 Reverse Steps 7 1 to complete Burner screw locations Slide burner to the left and lift out tooltip tooltip tooltip tool...

Страница 107: ...er to motor by disconnecting black and black wire and white and black wire Diagram 8 power vent motor is now free from the unit 5 Loosen 4 screws and slide shield up and out Diagram 2 once access has been made into power vent housing you can remove the pressure switch and fan motor 6 Removing the pressure switch by disconnecting red and blue wires from pressure switch Diagram 3 7 DisconnectHosefro...

Страница 108: ...installed for servicing from inside 1 Turn off the power 2 Remove8Phillipsheadscrewsfromtherearofthepowervent seeDiagram1 3 Slide the power vent housing out through the back as shown in Diagram 2 4 Turn the power vent over to the front side Diagram 3 5 Follow Steps 1 9 on previous page Front of power vent Diagram 1 Diagram 2 Diagram 3 ...

Страница 109: ...City Series CB72EPV 109 parts list 24 21 44 23 22 25 31 26 22 30 34 43 37 33 28 29 35 32 36 45 22 42 38 40 41 38 39 13 18 17 16 15 19 20 10 2 5 4 6 7 8 9 11 12 14 1 CB72EPV Main Assembly ...

Страница 110: ...t Bottom Right 38 940 437 P Replacement Side Inner Ceramic Glass Each 39 940 499 P Replacement Front Inner Ceramic Glass Each Part Description 40 940 500 P Outer Barrier Glass Front Complete Includes Bracket 41 940 502 P Outer Barrier Glass Right Complete Includes Bracket 42 940 503 P Outer Barrier Glass Left Complete Includes Bracket 43 666 534 Inner Glass Safety Rest 44 666 070F Access Plate 45 ...

Страница 111: ...34 Glowing Wool Black Sea 6 Gram N S 948 078 Glass Suction Cup Each N S 948 020 Clip Spring 0 20 x 0 375 1095 Bt N S 671 081 Barrier Glass Support Damper Right N S 671 082 Barrier Glass Support Damper Left Accessories Part Description N S 946 780 Crushed Glass Coal Black 3 4in N S 946 781 Crushed Glass Iceberg Chips 3 4in N S 946 675 Black Reflective Crystals 1 pound N S 946 676 Copper Reflective ...

Страница 112: ... 946 130 Power Vent SS Outer Perimeter Trim 7 946 157 Power Vent SS Water Deflector 8 911 047 Silicone Tubing Sold Per Foot 6 inches required For Power Vent 9 946 163 Pressure Switch Sensor Bracket 10 946 539 Power Vent Outer Intake Assembly N S 946 540 Power Vent Inner Intake Assembly N S 911 254 Pressure Switch Wire Harness Blue Red N S 911 255 Pressure Switch Wire Harness Shrink Wrapped Blue Re...

Страница 113: ...City Series CB72EPV 113 notes ...

Страница 114: ...s Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled compo...

Страница 115: ...lation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance are ...

Страница 116: ...uld consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief descrip...

Страница 117: ...or us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANA...

Страница 118: ...118 City Series CB72EPV ...

Страница 119: ......

Страница 120: ..._____________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Printed in Canada Regency and City Series are trademarks of FPI Fireplace Products International Ltd Copyright 2019 FPI Fireplace Products International L...

Отзывы: